Cisco Nexus 9516 Hardware Installation Manual page 62

Nx-os mode
Hide thumbs Also See for Nexus 9516:
Table of Contents

Advertisement

Overview of Supervisor Modules
Note
If there are two supervisors that are installed in the chassis, both must be the same type as shown in the
following table:
Table 2:
Active Supervisor
Supervisor A
Supervisor B
Supervisor A+
Supervisor B+
Supervisor modules are automatically powered up and started with the switch.
To understand the terms that are used for the supervisors, see the following table.
Module Terms
module-27 and module-28
sup-1 and sup-2
sup-active and sup-standby
Cisco Nexus 9516 NX-OS Mode Switch Hardware Installation Guide
52
Standby Supervisor
Supervisor A
Supervisor B
Supervisor A+
Supervisor B+
Usage
Description
Fixed
• Module-27 refers to the supervisor module in chassis
slot 27 (labeled as SUP 1 on the chassis).
• Module-28 refers to the supervisor module in chassis
slot 28 (labeled as SUP 2 on the chassis).
Fixed
• sup-1 refers to the supervisor module in the SUP 1 slot
(slot 27 in the CLI output).
• sup-2 refers to the supervisor module in the SUP 2 slot
(slot 28 in the CLI output.
Relative
• sup-active refers to the active supervisor
module—relative to the slot that contains the active
supervisor module.
• sup-standby refers to the standby supervisor
module—relative to the slot that contains the standby
supervisor module.
Managing the Switch
Is Combination Allowed?
Yes
Yes
Yes
Yes