Further explanations on the use of the "SD-TU Interface" software can be found in the software's
own on-line help.
5.2.1

SW updating procedure

1. Switch on the SACE PR010/T test unit.
2. Connect the SACE PR010/T test unit (connector 3) to one of the PC's serial ports (COM1...
COM4) using the cable supplied.
3. Run the "SD-TU Interface.exe" program.
4. From the list of devices that appears in the "Device selection" window on the left of the
screen, use the mouse (holding down the left key) to select the device you want, dragging it
into the "Device" window that appears on the right.
5. Repeat the selection operation indicated in point 4 for all the devices you want to insert
(when the memory available is exhausted this is indicated with the message "PR010/T
memory completely filled!!").
6. Select Program/From configuration on the PR010/T menu.
7. Now go to the PR010/T unit and select the 4.Update SW menu from the main menu. This
message will appear:
'Update SW'
'ENTER to confirm'
8. Press ENTER on the SACE PR010/T unit to display the following message:
'Waiting SW update'
9. Before one minute elapses, press OK in the window displayed on the PC. The SACE
PR010/T unit will now display the message:
'SW Updating in progress'
accompanied by a progressive status bar indicating the download time remaining. The
maximum duration of the procedure may be several minutes, depending on the number of
devices selected; the "programming status" bar is displayed on the PC monitor in the
"Program PR010/T" window, indicating how the updating is proceeding. If the file is
successfully downloaded, the SACE PR010/T unit will display the following message:
"End SW updating"
"SW Ver. X.X"
"Press ESC to restart"
while the PC will display the message:
"PR010/T successfully programmed"
Press ESC on the SACE PR010/T unit to restart the unit with the new software version.
Close the PC application.
10. If the file is not successfully downloaded, the SACE PR010/T unit will display the
following message:
'WARNING.SW updating failed'
'Press ESC to restart'
and the PC will display the message:
'Time out error: cannot contact PR010/T'
11. Press ESC on the SACE PR010/T unit to return to the screen:
'Program failed'
'ENTER for recovery'
12. Select PROGRAM/from CONFIGURATION in the "PR010/T Program" of the PC.
ABB SACE