ABB SACE PR010/T Instructions Manual page 23

Hide thumbs Also See for SACE PR010/T:
Table of Contents

Advertisement

COMPATIBILITY BETWEEN WINDOWS OPERATING SYSTEMS
Operating
Installation
System
requirements
Windows XP
Any user
or earlier
Windows 7
Administrator
user
Windows 10
Administrator
user
Updating of faults described in chap. 6.7 of Instruction RH0025002:
Faults
Difficulties in
updating PR010/T:
- Display locked on
"updating".
7
- Display locked on
start-up screen.
ABB
ABB
SACE
AND SD-TEST UNIT INTERFACE
Operating
requirements
Any user
Any user
Administrator
user
ERROR MESSAGES, TROUBLESHOOTING
Causes and errors
During an update could be
caused by:
Power outage.
-
Cable between PR010/T
-
and PC has detached.
Driver of serial line to PC
-
is locked.
SACE
PR010/T
Notes
(1)
(1)
Use with "non administrator" profile
can be obtained by installing the latest SD-
Test Bus Interface version available (from file
1SDC200002X0005 15.zip or more recent)
Checks and remedies
1. Shut down PR010/T and remove
2.
3.
4.
RH0025002
UPDATING 2017
power supplier if connected.
Restart PR010/T.
Press STOP button within 2s from
powering: this will prepare unit for
re-programming.
Comply
with
instructions
display.
L7680
on
1/1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents