Dip Switch Setting; Functions; Bootloader; Mainapplication (Normal Mode) - JCM GLOBAL DT-300 Series Operator Integration Manual

Download tool
Table of Contents

Advertisement

3. When removing the SD Card from the DT-300™,
push in on the SD Card in the insertion direction
once and then pull the SD Card out of the DT-
300™ Device.
NOTE: Do NOT push the SD Card in by
using excessive force!

DIP Switch Setting

DIP Switch Settings are necessary to communicate
with the DT-300™ and a Validator. Refer to "Com-
patibility" on page 14 of this Guide for proper DIP
Switch Settings related to each Validator Model.

Functions

The following two (2) Functions exist for the DT-
300™ Device:
B
OOTLOADER
The Bootloader Function contains the following
two (2) Modes:
• "BlueWaveDX Firmware Update Mode" to
upgrade the Firmware in the DT-300™ Device
• "BlueWaveDX EEPROM Update Mode" to
update the EEPROM data within the DT-300™
Device.
M
A
(N
AIN
PPLICATION
MainApplication (Normal Mode) contains the 
following two (2) Functions:
• "Firmware Update Function" to upgrade the
Firmware within the Validator
• "Acceptance Log Function" to receive and
display the Acceptance Log.

Boot Mode

When the DT-300™ is initialized, three (3) Modes
will be available. Select one Mode by using the
Direction Key Button to move and select to the
desired Operational Mode (See Table 5).

Table 5 Boot Mode Selection

Mode
DT-300 Firmware Update Mode
DT-300 EEPROM Update Mode
Normal Mode (MainApplication)

Authentication

When the MainApplication is booting, the DT-
300™ will authenticate itself with the information
on the SD Card.

USB Cable Connection

Perform the following steps to connect a Power-
Supplied Validator to the DT-300™ Device:
1. Connect the USB Cable A Terminal to the DT-
300™ Unit's Connector "A" Port (See Figure 9
a).
P/N 960-000167R_Rev. 1 {EDP #214645}
DT-300™ Series Download Tool Operator Integration Guide
M
)
ORMAL
ODE
Direction Key Button
UP + DOWN
LEFT + RIGHT
N/A (except the other
combinations)
2. Connect the USB Cable B or Mini-B terminal to
the Validator's USB Port (See Figure 9 b).
NOTE: Refer to "Compatibility" on
page 14 of this Guide to select the "B" or
"Mini-B" Connection Terminal.
a
NOTE: Validator power must be supplied.
Figure 9 Cable Connection
Operation Procedures 
(MainApplication)
This portion provides each MainApplication 
procedure of the DT-300™ Device Operation.
F
U
F
IRMWARE
PDATE
To update the Firmware of the Validator, proceed 
as follows:
1. Make sure that the SD Card contains the required
Software Data File (Refer to "Software Data File"
on page 13 of this Guide for details regarding
selection of the correct Software Data File).
2.
Turn the DT-300™ Power Switch ON; an SD
Card check will begin as shown in Figure 10.
Figure 10 SD Card Confirmation Screen 1
NOTE: Product specifications (e.g.,
version) may vary from illustrations, and
are subject to change without notice.
3. Select "
FIRMWARE UPDATE
Function Selection Screen shown in Figure 11,
and press the
OK
Erase process.
Figure 11 Function Selection Screen 1
4. Connect the USB Port of the Validator to the DT-
300™ Device using a proper USB Cable.
5. Select the download File desired by pressing the
Key
or the
UP
© 2013, Japan CashMachine Co., Limited
6
b
UNCTION
" Function on the
Key
to begin the Firmware
Key
, and then
DOWN

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for JCM GLOBAL DT-300 Series

This manual is also suitable for:

Bluewavedx

Table of Contents