Options - Carrier AquaForce PUREtec 30XAV-ZE 401 Installation, Operation And Maintenance Instructions

Variable-speed air-cooled screw chillers with r1234ze (e)
Table of Contents

Advertisement

10 - oPTIons

options
IP54 control box
Grilles and enclosure panels
Enclosure panels
Evaporator freeze protection
Evap.and hydraulic mod. freeze
protection
Master/slave operation
Fuses on main disconnect
switch
Single power connection point
Evaporator and Pump/s with
aluminium jacket
Service valve set
Compressor discharge valves
Evaporator with one pass less
21 bar evaporator
Reversed evaporator water
connections
HP single-pump hydronic
module
HP dual-pump hydronic module 116S
LP single-pump hydronic
module
LP dual-pump hydronic module 116U
J-Bus gateway
Lon gateway
Bacnet over IP gateway
Energy Management Module
Leak detection
Dual relief valves installed w/
3-way valve
Compliance with Swiss
regulations
Compliance with Russian
regulations
34
no.
description
20A
Increased leak tightness of control boxes
23
Metal grilles on the 4 unit sides, plus side
enclosure panels at each end of the coil
23A
Side enclosure panels at each end of the coil
41A
Electric resistance heater on the evaporator and
discharge valve
41B
Electric resistance heater on evaporator,
discharge valve and hydronic module
58
Unit equipped with supplementary water outlet
temperature sensor kit to be field-installed
allowing master/slave operation of two units
connected in parallel
70D
Factory installed additional fuses, one per each
phase, to protect main switch and associated
cables from over-current flow (Note: frequency
drives and electronic boards are protected
as standard by dedicated fuses. Option 70D
recommended when compliant protection
devices on field not present)
81
Unit power connection via one main supply
connection (include option 70D)
88A
Evaporator and Pumps covered with an
aluminium sheet for thermal insulation
protection
92
Liquid line valve (evaporator inlet), compressor
suction and discharge line valves and
economiser line valve
93A
Shut-off valve on the compressor discharge
piping
100C
Evaporator with one pass on the water side.
Evaporator inlet and outlet on opposite sides.
104
Reinforced evaporator for extension of the
maximum water-side service pressure to 21 bar
(standard 10 bar)
107
Evaporator with reversed water inlet/outlet
116R
Complete hydronic module equipped with
water filter, relief valve, one high pressure pump
and drain valve. For more details, refer to the
dedicated chapter (expansion tank not included)
Complete hydronic module equipped with water
filter, relief valve, two high pressure pumps
and drain valve. For more details, refer to the
dedicated chapter (expansion tank not included)
116T
Complete hydronic module equipped with
water filter, relief valve, one low pressure pump
and drain valve. For more details, refer to the
dedicated chapter (expansion tank not included)
Complete hydronic module equipped with
water filter, relief valve, two low pressure pumps
and drain valve. For more details, refer to the
dedicated chapter (expansion tank not included)
148B
Two-directional communication board
complying with JBus protocol
148D
Two-directional communication board
complying with Lon Talk protocol
149
Two-directional high-speed communication
using BACnet protocol over Ethernet network
(IP)
156
Control board with additional inputs/outputs.
See Energy Management Module option
chapter
159
0-10 V signal to report any refrigerant leakage
in the unit directly on the controlller (the
leak detector itself must be supplied by the
customer)
194
Three-way valve upstream of the relief valves on
the evaporator and the oil separator
197
Additional tests on the water heat exchangers:
supply (additional of PED documents)
supplementary certificates and test
certifications
199
GOST certification
avantages
Protects the inside of the electrical box from dusts and sand.
In general this option is recommended for installations in
polluted environments
Improves aesthetics, protection against intrusion to the unit
interior, coil and piping protection against impacts.
Improves aesthetics, coil and piping protection against
impacts.
Evaporator freeze protection down to -20°C outside
temperature
Evaporator and hydronic module freeze protection down to
-20°C outside temperature
Optimised operation of two chillers connected in parallel with
operating time equalisation
No need for separate fuse box. Save time and money on site
installation and avoid additional space requirement
Quick and easy installation
Improved resistance to aggressive climate conditions
Allow isolation of various refrigerant circuit components for
simplified service and maintenance
Simplified maintenance
Easy to install, depending on site. Reduced pressure drops
Covers applications with a high water column evaporator side
(typically high buildings)
Easy installation on sites with specific requirements
Easy and fast installation (plug & play)
Easy and fast installation (plug & play). Increased system
reliability
Easy and fast installation (plug & play)
Easy and fast installation (plug & play). Increased system
reliability
Connects the unit by communication bus to a building
management system
Connects the unit by communication bus to a building
management system
Easy and high-speed connection by ethernet line to a
building management system. Allows access to multiple unit
parameters
Extended remote control capabilities (Set-point reset, ice
storage end, demand limits, boiler on/off command...)
Immediate customer notification of refrigerant losses to the
atmosphere, allowing timely corrective actions
Valve replacement and inspection facilitated without
refrigerant loss. Comforms to European standard EN378/
BGVD4
Conformance with Swiss regulations
Conformance with Russian regulations
Utilisation
401-901
401-901
401-901
401-901
Sizes 401-901
only
401-901
501-901
(standard on
size 401)
651-901
Sizes 401/501
only
401-901
401-901
401-901
401-901
Sizes 401/501/
701/851/901
only
Sizes 401/501
only
Sizes 401/501
only
Sizes 401/501
only
Sizes 401/501
only
401-901
401-901
401-901
401-901
401-901
401-901
401-901
401-901