Options - Carrier AquaForce 30XAV 500 Installation, Operation And Maintenance Instructions

Variable-speed air-cooled screw chillers
Table of Contents

Advertisement

10 - OPTIONS

Options
IP54 control box
Grilles and enclosure panels
Enclosure panels
Evaporator freeze protection
Evap.and hydraulic mod.
freeze protection
Master/slave operation
Fuses on main disconnect
switch
Single power connection point 81
Evaporator and Pump/s with
aluminium jacket
Service valve set
Compressor discharge valves 93A
Evaporator with one pass less 100C
21 bar evaporator
Reversed evaporator water
connections
HP single-pump hydronic
module
HP dual-pump hydronic
module
LP single-pump hydronic
module
LP dual-pump hydronic
module
J-Bus gateway
Lon gateway
Bacnet over IP gateway
Energy Management Module
Leak detection
Dual relief valves installed w/
3-way valve
Compliance with Russian
regulations
Insulation of the evap. in/out
ref.lines
Low noise level
No.
Description
20A
Increased leak tightness of control boxes
23
Metal grilles on the 4 unit sides, plus side
enclosure panels at each end of the coil
23A
Side enclosure panels at each end of the coil
41A
Electric resistance heater on the evaporator and
discharge valve
41B
Electric resistance heater on evaporator,
discharge valve and hydronic module
58
Unit equipped with supplementary water outlet
temperature sensor kit to be field-installed
allowing master/slave operation of two units
connected in parallel
70D
Factory installed additional fuses, one per each
phase, to protect main switch and associated
cables from over-current flow (Note: frequency
drives and electronic boards are protected as
standard by dedicated fuses. Option 70D
recommended when compliant protection
devices on field not present)
Unit power connection via one main supply
connection (include option 70D)
88A
Evaporator and Pumps covered with an
aluminium sheet for thermal insulation protection
92
Liquid line valve (evaporator inlet), compressor
suction and discharge line valves and
economiser line valve
Shut-off valve on the compressor discharge
piping
Evaporator with one pass on the water side.
Evaporator inlet and outlet on opposite sides.
104
Reinforced evaporator for extension of the
maximum water-side service pressure to 21 bar
(standard 10 bar)
107
Evaporator with reversed water inlet/outlet
116R
Complete hydronic module equipped with water
filter, relief valve, one high pressure pump and
drain valve. For more details, refer to the
dedicated chapter (expansion tank not included)
116S
Complete hydronic module equipped with water
filter, relief valve, two high pressure pumps and
drain valve. For more details, refer to the
dedicated chapter (expansion tank not included)
116T
Complete hydronic module equipped with water
filter, relief valve, one low pressure pump and
drain valve. For more details, refer to the
dedicated chapter (expansion tank not included)
116U
Complete hydronic module equipped with water
filter, relief valve, two low pressure pumps and
drain valve. For more details, refer to the
dedicated chapter (expansion tank not included)
148B
Two-directional communication board complying
with JBus protocol
148D
Two-directional communication board complying
with Lon Talk protocol
149
Two-directional high-speed communication using
BACnet protocol over Ethernet network (IP)
156
Control board with additional inputs/outputs. See
Energy Management Module option chapter
159
0-10 V signal to report any refrigerant leakage in
the unit directly on the controlller (the leak
detector itself must be supplied by the customer)
194
Three-way valve upstream of the relief valves on
the evaporator and the oil separator
199
GOST certification
256
Thermal insulation of the evaporator entering/
leaving refrigerant lines with flexible, anti-UV
insulant
257
Sound insulation of main noise sources
combined with fans speed management
(includes option 279)
Avantages
Protects the inside of the electrical box from dusts and sand.
In general this option is recommended for installations in
polluted environments
Improves aesthetics, protection against intrusion to the unit
interior, coil and piping protection against impacts.
Improves aesthetics, coil and piping protection against
impacts.
Evaporator freeze protection down to -20°C outside
temperature
Evaporator and hydronic module freeze protection down to
-20°C outside temperature
Optimised operation of two chillers connected in parallel with
operating time equalisation
No need for separate fuse box. Save time and money on site
installation and avoid additional space requirement
Quick and easy installation
Improved resistance to aggressive climate conditions
Allow isolation of various refrigerant circuit components for
simplified service and maintenance
Simplified maintenance
Easy to install, depending on site. Reduced pressure drops
Covers applications with a high water column evaporator side
(typically high buildings)
Easy installation on sites with specific requirements
Easy and fast installation (plug & play)
Easy and fast installation (plug & play). Increased system
reliability
Easy and fast installation (plug & play)
Easy and fast installation (plug & play). Increased system
reliability
Connects the unit by communication bus to a building
management system
Connects the unit by communication bus to a building
management system
Easy and high-speed connection by ethernet line to a
building management system. Allows access to multiple unit
parameters
Extended remote control capabilities (Set-point reset, ice
storage end, demand limits, boiler on/off command...)
Immediate customer notification of refrigerant losses to the
atmosphere, allowing timely corrective actions
Valve replacement and inspection facilitated without
refrigerant loss. Comforms to European standard EN378/
BGVD4
Conformance with Russian regulations
Prevents condensation on the evaporator entering/leaving
refrigerant lines
6 to 10 dB(A) quiter than standard unit (depending model
and size). Refer to the physical data table for detailed values
Utilisation
500-1150
500-1150
500-1150
500-1150
Sizes 500/600
only
500-1150
600-1150
(standard on
size 500)
800-1150
Sizes 500/600
only
500-1150
500-1150
500-1150
500-1150
Sizes 500/600/
950/1050/1150
only
Sizes 500/600
only
Sizes 500/600
only
Sizes 500/600
only
Sizes 500/600
only
500-1150
500-1150
500-1150
500-1150
500-1150
500-1150
500-1150
500-1150
500-1150
33