How to replace the PCB interference filter
9.2
9.2.1
Version 10.2005 and
before
38
Elmasonic S 60 (H) – S 100 (H)
The PCB interference filter is screwed to the back of the unit.
The mains input socket is soldered to the PCB interference filter
and must be replaced with the PCB.

Electric connections

The units manufactured in 10.2005 or before are fitted with the
PCB interference filter illustrated below.
When ordered as a spare part the new version will be delivered
(see description for year of manufacturing 11.2005 or later). For
mounting follow the instructions on mounting the new version.
Illustration 9.10. Connections PCB interference filter
A
Connection for heating element(s) (mains voltage). On units
with more than one heating element, the heating elements are
connected to plug distribution contacts. Polarization of the
cables is irrelevant.
B
Connections to PCB control (mains voltage). Polarization of
the cables is irrelevant.