  • Page 1 Operating Instructions Elmasonic Denta Pro  english ...
  • Page 2: Table Of Contents

    Instructions for the use of the unit ......4 Functioning ..............5 Ultrasonic cleaning factors ........5 Product description ............. 6 Elmasonic Denta Pro product features ..... 6 CE conformity ............6 Delivered equipment ..........6 Unit font view / side view .......... 7 Unit back view ............
  • Page 3: General

    Caution The signal word caution warns of the risk of light injury or damage to the equipment. Attention The signal word attention warns of the risk of damage to the equipment. © Elma Schmidbauer GmbH...
  • Page 4: Instructions For The Use Of The Unit

    Important safety warnings Instructions for the use of the unit Intended use The present Elma ultrasonic cleaning unit has been designed for the treatment of items and liquids only. No cleaning of living beings or plants! User Operation of the unit by authorized and instructed staff only.
  • Page 5: Functioning

    Cleaning media For saponification and removal of the dirt particles a suitable cleaning agent is required. Elma has a large range of cleaning media on offer. Cleaning chemicals are also necessary to reduce the surface tension. This increases considerably the efficiency of the ultrasonic activity.
  • Page 6: Product Description

    • automatic switch-off after 12 h operation to prevent unintended permanent operation. CE conformity The present Elma ultrasonic unit is in compliance with the CE marking criteria. The declaration of conformity is available from the manufacturer. Delivered equipment •...
  • Page 7: Unit Font View / Side View

    This level should not be exceeded even with cleaning items inside. Plastic carrying handles for the safe transportation of the unit even with hot casing. Operating panel for the control of the operating functions. Description see section. © Elma Schmidbauer GmbH...
  • Page 8: Unit Back View

    Mains supply socket for quick and easy removal of the mains cable e.g. for transportation purposes Turning knob for draining the tank Illustration 4.6 View turning knob for draining the tank Vertical position: drain open Horizontal position: drain shut © Elma Schmidbauer GmbH...
  • Page 9: Description Of Operating Elements

    Preset cleaning programmes provide specially defined combinations of different cleaning modes: degas – boost – normal – sweep, the various modes can be distinguished through different operating sounds. Each programme operates at a specific predefined temperature (Denta Pro H only). © Elma Schmidbauer GmbH...
  • Page 10: Description Cleaning Programs

    60°C EC25 or more plaster remover Cement removal 6 Min. 30°C EC40 or more cement remover Enzymatic cleaner 15 Min. 40°C enzymatic instrument cleaner Acid basic cleaning 10 Min. 30°C EC60 or more acid instrument cleaner © Elma Schmidbauer GmbH...
  • Page 11: Initial Operation

    You can also return the packing to the manufacturer free destination (to your account). Check for transport Check the Elmasonic Denta Pro for possible transport damages damages before initial operation. In case of visible damage do not connect the unit to the mains.
  • Page 12: Set Up Of The Liquid Drain

    Ensure that the values indicated on the nameplate of the unit must correspond with the available connecting conditions. The mains plug must be connected to an easily accessible socket only, as it serves as interrupted device! © Elma Schmidbauer GmbH...
  • Page 13: Putting Unit Into Operation

    Observe the instructions on limitations of use given in section 8.2. For queries please contact the manufacturer or your supplier. Danger of damage to the transducer system! Fill no liquid > 60°C and < 10°C in the ultrasonic tank. ATTENTION © Elma Schmidbauer GmbH...
  • Page 14: Placement Of Cleaning Items

    (accessory equipment). Acid tank For the use of cleaning chemicals which might destroy or damage the stainless steel tank use a separate container. For the special plastic cleaner tank for acid chemicals please contact your supplier. © Elma Schmidbauer GmbH...
  • Page 15: Ultrasonic Cleaning Process

    Please observe that the temperature of the cleaning media remains below 42°C when cleaning parts contaminated with fresh protein or blood. It is the user’s responsibility to check the cleaning results. The manufacturer cannot guarantee cleaning process and cleaning results. © Elma Schmidbauer GmbH...
  • Page 16: Starting The Cleaning Process Manually

    Off position. Individual operation This option is available on Elmasonic Denta Pro H units only: 50°C / 70°C If you want to operate the unit without any of the preset cleaning programmes and a certain bath temperature is required, switch the turning knob to 50°C or 70°C, respectively.
  • Page 17: After The Cleaning

    Drain the liquid as soon as it is dirty or when the unit is not operated over a prolonged period of time. Certain residues and types of contamination may destroy or damage the stainless steel tank. Use the quick-drain duct to drain the cleaning tank. © Elma Schmidbauer GmbH...
  • Page 18: Cleaning Media

    (e.g. beaker) with sufficient ventilation; this vessel (beaker) can then be put into the stainless steel tank which is filled with non-flammable liquid (water with a few drops of surfactant). © Elma Schmidbauer GmbH...
  • Page 19: Limitations On Aqueous Cleaners

    For queries please contact the manufacturer or your supplier. List of recommended cleaning media Elma has a large range of suitable cleaning products on offer developed by chemical engineers in the Elma laboratory. Please contact your supplier to find the most suitable cleaning chemical for your application.
  • Page 20: Dental

    For the hygienical removal of amalgam remains, blood, tissue, etc.; with anti-corrosion effect. elma clean 60 Acid cleaning concentrate for instruments made of stainless steel, glass and plastic. Removes corrosion, rust films and mineral deposits. © Elma Schmidbauer GmbH...
  • Page 21: Maintenance

    Care of transducer Lime deposits on the stainless-steel tank can be cleaned gently tank with softening agents e.g. elma clean 40 or elma clean 115C (operate the unit with concentrate + water). Grid of air fan Check regularly the grid of the air fan at the bottom of the unit (not existent in all units).
  • Page 22: Repair

    *standard sine-wave modulation. The choice of the waveform has been matched to the relevant tank size. The signal form of the wave results in a factor 4 or 8 for the ultrasonic peak max., depending on the modulation of the wave. © Elma Schmidbauer GmbH...
  • Page 23: Trouble Shooting

    • • Unsatisfactory cleaning no or unsuitable cleaning use suitable cleaning results medium used medium • • cleaning time too short repeat cleaning cycle © Elma Schmidbauer GmbH...
  • Page 24: Putting Out Of Action And Waste Disposal

    Putting out of action and waste disposal Putting out of action and waste disposal The unit can be taken to metal and electronics recycling stations or returned to the manufacturer. © Elma Schmidbauer GmbH...