8.2
NOTE
8.2.1
8.2.2
8.2.3
© Elma Schmidbauer GmbH

Elmasonic S350R | S450H | S500HM | S900H

The PCB control is clipped into the unit. It can be removed
without any tool.
Some of the electronic components on the PCB control are
sensitive against electrostatic charging. These charges may
destroy the component. Therefore, for the correct handling of
the PCB control please observe the instructions on ESD
protection (section 1.5).

Electric connections

Illustration 8.5. Connections PCB control
A
Connections for temperature gauge
B
Connection for fan (on S120H and lager)
C
Voltage supply PCB / voltage supply heating element(s)
(mains voltage)
D
Connections control line to power module

How to remove the PCB control

Follow the instructions given in section 8.1.

How to mount the PCB control

Follow the instructions given in section 8.2.
SM_Elmasonic_S_02.2018_EN
How to replace the PCB control
A
D
B
C