4) Set the UP and DOWN Limits.
1. Identify the UP limit switch push button, on the CMO motor head.
Press the UP button of the transmitter and let the end-product reach
the required UP position, then stop it.
2. Unlock the UP limit switch push button by pressing and releasing it.
3. Repeat the above operation to set the DOWN end limit.
4. Replace the protective cap.
5

Installer Mode

This mode allows for readjusting of the end limits and final programming
IMPORTANT
If the installation is made up of several LT RTS CMO motors,
This will avoid interference with the first programming of each
same power supply, please
*If the INSTALLER MODE directly follows FACTORY MODE, with no power interruption to the motor, go directly to Section 5.3
1) Provide power to the
transmitter in order to take control of the motor. Then check that the LT RTS CMO motor is in INSTALLER MODE.
In this mode the
LT RTS CMO
2) If the end limits need to be readjusted, please refer to section - 4.3 and 4.4
3) Record the first Transmitter or Channel. On 4 channel transmitters, verify the desired channel selection before pressing the
the programming button.
Press the programming button
on the RTS transmitter
6

User Mode

This mode is for operating the motor by the end user
Two intermediate postions (IP1 & IP2) can be programmed into the LT RTS CMO motor. IP1 is set using the UP limit as a
reference, and IP2 is set from the DOWN limit as a reference.
1) Record the INTERMEDIATE POSITION (IP1) referenced from the UP LIMIT of the end-product
Set the end-product at
its UP limit with the
RTS transmitter
refer to the Warning note in Section
LT RTS CMO
motor. Press
motor runs when a directional button on the transmitter is
Push simultaneously on the
STOP and DOWN button of
the RTS transmitter and release
them when the end-product begins
to move.
The buttons shown may not correspond to the correct directions on the end-product.
White Button
Yellow Button
only one
LT RTS CMO
LT RTS CMO
6.6 - "Resetting motors back to USER MODE".
SIMULTANEOUSLY
on the
STOP
Stop the end-product at the
intermediate position (IP1) you
wish to achieve (if necessary,
adjust this position with UP and
DOWN push buttons).
motor must be powered during programming.
motor. If several motors are connected on the
UP
and
DOWN
buttons of the RTS
pressed and held
Release it when the end-product jogs briefly UP/DOWN
indicating that the transmitter has been memorized
into the motor. The motor is now in USER MODE
(momentary fashion).
5s
IP1
Push the STOP button of the
RTS transmitter for five seconds.
The end-product jogs
briefly UP/DOWN indicating
that the LT RTS CMO motor
has memorized the first
intermediate position (IP1)

Advertisement