SOMFY LS40 Manual

SOMFY LS40 Manual

Motorisation of window coverings using somfy motors
Hide thumbs Also See for LS40:

Advertisement

Motorisation of
Window Coverings
using
Somfy Motors

Advertisement

Table of Contents
loading

Summary of Contents for SOMFY LS40

  • Page 1 Motorisation of Window Coverings using Somfy Motors...
  • Page 2 • The wheel drives the roller tube • The roller tube drives the crown • The crown drives the limit switch within the motor ATTENTION Somfy Motors are not waterproof Do not hose down with water. All motors mounted externally require covering!
  • Page 3 Running Current = 0.5 amps (maximum) Cable length = 2.5m Cable size = 3 x 0.75 Important! LS40 motors must never be wired in parallel. Damage caused by parallel wiring will not be covered under warranty. LT50 Motor Suitable for roller blinds and awnings...
  • Page 4 Motorisation of Window Coverings using Somfy Motors ILT Motor Suitable for roman and roller blinds Power Cable Blue = Neutral Brown = Active Green/Yellow = Earth Cable length = 2.5m Cable size = 3 x 0.75 Data Cable (4 wire flat phone cable)
  • Page 5 Motorisation of Window Coverings using Somfy Motors Altus 50 Motor (integrated Radio receiver) Suitable for roller and roman blinds plus awnings Power Cable Blue = Neutral Brown = Active Green/Yellow = Earth Nominal Supply Voltage = 220/240V Current consumption at nominal torque = 270 watts (maximum) Running Current = 1.2 amps (maximum)
  • Page 6 Do Not use other switches and controls other than those recommended by Somfy. When using a Somfy control box plug in type, make sure the power supply is switched off before plugging in. ! Use one switch per motor. Do not wire one motor to several switches without...
  • Page 7 There will be constant feedback from one motor to the other causing the motors to continuously change direction, but with very little travel. The motors will eventually burn out. Solution For one of more motors use a Somfy group controller.
  • Page 8 • Simultaneous contact between a common up and down to create a stop • CD4 Venetian module available for control of Venetian blinds • Dimensions: 112 (h) x 52 (w) x 106 (d) Note: Earth wire not required for LS40 motors...
  • Page 9 Motorisation of Window Coverings using Somfy Motors Integration to BMS using LS40 or LT50 Option 2 Moduline Controllers • DIN rail mounted controllers • Requires 240 V power supply • Dry contact impulse switching (impulse contact closure of 1 second minimum) •...
  • Page 10 Motorisation of Window Coverings using Somfy Motors Integration to BMS using LS40 or LT50 Option 3 Animeo IB+ AC Motor Controller • Requires 240V power supply and has 240V latched output • Provides interlocking between up and down commands • Dry contact impulse switching (impulse contact closure of 1 second minimum) •...
  • Page 11 Motorisation of Window Coverings using Somfy Motors Integration to BMS using ILT motors Phone Plug Connector • Allows for connection between RJ11 connector and standard data cable • Dry contact impulse switching (impulse contact closure of 1 second minimum) • Contact between common and up or common and down to activate motor •...
  • Page 12 Motorisation of Window Coverings using Somfy Motors Integration to BMS using Altus motors Option 1 Busline Transmitter (single channel) • Requires 240V power supply • Converts dry contact closure to Radio frequency • Dry contact impulse switching (impulse contact closure of 5 seconds minimum) •...
  • Page 13 Motorisation of Window Coverings using Somfy Motors Integration to BMS using Altus motors Option 2 Busline Transmitter (Five channel) • Control of up to 5 groups of motors • Requires 240V power supply • Converts dry contact closure to Radio frequency •...
  • Page 14 Motorisation of Window Coverings using Somfy Motors Option 2 (cont) Busline Transmitter (Five channel)
  • Page 15 Motorisation of Window Coverings using Somfy Motors Integration to BMS using Concept 25 IRS 300 • Supply voltage 24V DC • Dry contact impulse switching (impulse contact closure of 5 seconds minimum) • Contact between common and up or common and down to activate motor •...