4) Add or Delete an EOLIS or SOLIRIS Sensor RTS in the memory of LT RTS CMO motor
a) Enter the "PROGRAMMING STATE"
>2 Seconds
Press for more than 2 seconds on the
Transmitter
programming button of an RTS transmitter/
!
previously
channel which is already recorded in the motor.
recorded
b) To record or delete a sensor
-
+
-
+
c) To Erase all the sensors and record a new one
>7 Seconds
-
+
-
+
5) Resetting the motor's memory and recording a new
transmitter when the only transmitter is lost.
**
A.
Perform a power cut in the following sequence:
1. Power-off - 2 sec. Minimum
2. Power-on - 5 to 15 seconds
3. Power-off - 2 sec. minimum
4. Power-on
The end product moves for 5 seconds in one direction,
to indicate that the double power cut has been recorded.
The motor is in INSTALLER MODE for 2 minutes.
**RESETTING MOTORS BACK TO USER MODE
WARNING:
This type of power cut affects all
the LT RTS CMO motors on the same power line.
To avoid resetting of non-concerned
motors, press briefly any button of their assigned
transmitter/channel. (UP , STOP , or DOWN)
The non-concerned motors will exit INSTALLER
MODE and return to USER MODE.
Press BRIEFLY on the programming button
of the SOLIRIS RTS
sensor
.
Press for more than 7 SECONDS
on the programming button of the
new SOLIRIS RTS
sensor
.
LT RTS CMO motors will memorize up to 3 RTS Sensors
The end-product jogs briefly UP/DOWN
indicating that the LT RTS CMO motor is in
PROGRAMMING STATE.
The end-product jogs briefly UP/DOWN
If it is a new sensor:
If the sensor was previously recorded:
The end-product jogs briefly UP/DOWN
The memory of the receiver is cleared (all the previous
sensors are erased) and the new sensor is recorded.
!
>5 sec.
B.
Press more than 5 seconds on the programming button of the
NEW RTS transmitter. The end-product jogs briefly UP/DOWN
indicating that the transmitter has erased the previous
transmitter
and recorded the new one.
NOTE:
A double power cut cannot be achieved if the motor
is still in FACTORY or INSTALLER Mode. First program a
transmitter into the memory of the motor.
it will be recorded in the motor.
NEW TRANSMITTER
5 seconds
it will be deleted.

Advertisement