3

Installation Requirements

If the installation is made up of several RTS motors, only one
RTS motor must be powered during programming,
all other motors must be disconnected. This will avoid interferences
during the initial programming of each motor.
The mounting distance between 2 motor heads should not be less than
19 inches between RTS motor heads, to avoid possible interference.
Use only SOMFY RTS radio controls.
In order to avoid water penetration, form a "drip loop" with
the power cable and use a hood when required.
Use SOMFY accessories (adaptors, brackets, plug ends,...),
rated for the motor torque and total weight of the installation.
4

Factory Mode

This mode allows for
CONTROLLING THE LT RTS CMO MOTOR WHEN SWITCHING POWER ON FOR FIRST TIME
1) Two positions have to be set, the UP and DOWN limits. This is achieved with the mechanical CMO limit switch unit.
Provide power to the motor. Notice the motor will not respond to any transmitter until a transmitter is assigned to
communicate with the motors receiver.
A) Remove the protective cap covering the limit setting buttons on the motor head,
(replace when finished).
B) Depress fully both limit switch buttons. They will automatically lock in the down
position.
2) Assign the transmitter to communicate with the motor's receiver, push the UP and DOWN
buttons on the transmitter SIMULTANEOUSLY.
* In case of problems with FACTORY MODE, turn the power off to the motor for 2 sec. and then back on in order to reset it.
3) Check direction of operation. The DOWN button must correspond to DOWN on the end-product. In the case of an awning,
it will open or extend the awning. If the direction is wrong, change the direction as shown.
UP
STOP
DOWN
WARNING: For the
EOLIS/SOLIRIS RTS
receiver, must be configured correctly. The DOWN button MUST correspond to DOWN on the end-product. In the case of an
awning, it will open or extend the awning. If the UP button extends the awning, the wind sensor will also extend the awning
during windy conditions.
transmitter is verified.
rotation direction modification and
Press the stop button for
more than 5 seconds
SENSOR
THIS IS DANGEROUS!
to function properly, the transmitter which is memorized into the motor's
Damage and injury could occur. Do not proceed until proper operation of the
HOOD
The motor cable should not act as a direct conduit for the
water to enter the head of the motor (form drip loops).
NOTE: SOMFY motors conform to IP44 requirements
and as such must be protected against direct weather
elements such as rain, sleet,...etc.
setting of the end limits
Release both buttons after the end-product jogs
briefly UP/DOWN indicating that this transmitter
can operate the motor during programming. The
LT RTS CMO motor will now operate in a
momentary fashion.
Release the STOP button when the end-product
jogs briefly UP/DOWN indicating that the change
has been memorized in the motor. Verify that the
change took place before proceeding.