SICK Lector62 Series Online Help Manual

SICK Lector62 Series Online Help Manual

Image-based code readers, sopas parameter overview
Table of Contents

Advertisement

O N L I N E H E L P
Lector62x
Image-based code readers
SOPAS Parameter Overview

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lector62 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK Lector62 Series

  • Page 1 O N L I N E H E L P Lector62x Image-based code readers SOPAS Parameter Overview...
  • Page 2: Table Of Contents

    Output Format..................Output Format..................Output Hex-ASCII................. Output Control..................Output delay..................Data transmission point..............Output / Result 1................Output / Result 2................O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 3 CANopen Receive PDOs 1 .. 4............CANopen Transmit PDOs 1 .. 4............Classifier....................COB-ID Emergency Obj................ COB-ID RPDO user Dig. Input............. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 4 Data String Forwarding............... Date (YYYY-MM-DD)................Date...................... Duration....................Decoding....................Default Gateway.................. Default Data String................DeviceNet-Gateway................DHCP....................DHCP Fallback Mode................Image Diagnosis Settings..............O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 5 Errors in L-pattern................Error Score 1..................Fieldbus Gateway................Fixed size 1..................Fixed size 2..................Fixed size 3..................Fixed size 4..................Fixed Length..................8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 6 Inhibit Time..................Increment.................... Increment Configuration..............Increment source................Length of Input-Data................Internal....................Internal memory (permanent)............Internal memory (temporary)............. Interval....................IP-Address.................... IP port....................O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 7 MicroSD card..................Check min. number of valid codes............ Minimum bar width................Minimum cell size................Minimum....................with number..................Mode....................Module width..................8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 8 Check digit test..................103 Pulse....................103 Noise reduction................... 104 RDT ID....................104 Allow rectangular data fields.............. 105 Reduction of decoding time............... 105 O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 9 Serial AUX Interface................109 Serial host interface................109 Serial Host................... 109 Server / Client..................109 Server Address..................109 Service Information................110 SICK Visualization Platform..............110 Scripts....................110 Script List..................... 110 Slave Address..................110 SOPAS (PC)..................110 Save permanent.................. 110 Save Destination................. 111 Stacked Symbologies Active...............
  • Page 10 Apply Standard Parameters............... 127 Warning Score 1.................. 127 Web Server..................127 Enable webserver at boot-up of device..........127 Angle....................127 X-Coordinate..................128 O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 11 Aiming laser..................129 Select Directory................... 129 Destination Interface................130 Z-Coordinate..................130 Reset....................130 Code summarization................130 Use Additional Error Correction............130 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 12: About This Document

    All documentation and other downloadable content relating to the sensor can be found under Downloads. The SOPAS configuration software can be downloaded under Software. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 13: Sopas Parameter Overview

    2D code. NOTE The fewer code types are activated in parallel, the faster the decoding process. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 14: Components

    • : A 1 or A 1 B 2 C 2 OR 5 CHARACTERS Address The address of the image server to which the images for the SICK Visualization Platform are to be sent is specified under the Address parameter.
  • Page 15: Active

    SOPAS PARAMETER OVERVIEW Active The data output of the SICK Visualization Platform can be activated via the Active parameter. NOTE The device time must be set to operate the SVP. Active The event that activates the digital output is selected via the Active parameter.
  • Page 16: Activate Teach-In Mode

    This means the values remain available without a permanent supply volt‐ age, i.e., the values are still saved after the device is restarted. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 17: General Match-Code Teach-In Settings

    (RPDOs) that can be received by the script program. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 18: Number Of Pdos

    : The reading results are output if the code that has been read TEACH-IN2 CONDITION corresponds to the match code. TEACH-IN2 CONDITION O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 19: Output Format 1

    For each trigger (reading CONNECTION gate), a data string is transferred and displayed on the terminal. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 20: Output Format

    Time-controlled: If a time-controlled delay is set, the reading gate only opens once ■ a predefined time has elapsed after the trigger signal is issued. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 21: Output Delay

    1. Output / Result 2 Output / Result 2 group contains the parameters for adjusting digital output 2. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 22 : The output is deactivated if the code that has been read corre‐ TEACH-IN2 CONDITION sponds to the match code. TEACH-IN2 CONDITION O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 23: Output / Result

    Digital outputs 3 and 4 are not available via the 15-pin D-Sub port on the CDB620 or CDM420 connection module. They can only be utilized if a 17-pin open-ended cable is used. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 24 : The output is deactivated if the code that has been read corre‐ TEACH-IN2 CONDITION sponds to the match code. TEACH-IN2 CONDITION O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 25: Output / Result 4

    Digital outputs 3 and 4 are not available via the 15-pin D-Sub port on the CDB620 or CDM420 connection module. They can only be utilized if a 17-pin open-ended cable is used. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 26 : The output is deactivated if the code that has been read corre‐ TEACH-IN2 CONDITION sponds to the match code. TEACH-IN2 CONDITION O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 27: Evaluation Conditions

    (PLCs) into the code reader, meaning costs are reduced. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 28: Auto

    It is recommended that brightness tuning is only carried out when the system is stationary due to the time required for the brightness measurement and adjustment. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 29: Auto-Setup Via Function Button Menu

    AUTO-SETUP (standard or advanced) are still taken into consideration. The settings can also be con‐ figured using commands. A detailed list of commands can be obtained from SICK on request. Barcode Symbology...
  • Page 30: Base Cob-Id For Readresult Pdos

    All devices on the CAN network must run at the same data baud rate. The maximum length of cable for the network is dependent on the baud rate. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 31: Condition For Image Storing

    With this function, it is possible to prevent a particular product from leaving the produc‐ tion line. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 32: Usage Of Input Data

    A long shutter time offers a high level of brightness and, therefore, minimal image noise. This is the optimal setting for stationary or slow-moving objects. User Name A user name for the FTP image transfer to the SICK Visualization Platform is specified under the User Name parameter.
  • Page 33: Certain Numb. Of New Labels

    The mode should only be selected if it is necessary to replace a BMV/H. NOTE Some parameter values are not supported by all device types. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 34: Image Capturing Mode

    To change the size of the reading field, adjust the red marking by dragging and drop‐ ping or by entering the four % values. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 35: Image Selection

    Load image(s) You can use the Load image(s) button to display the images that have been transferred previously. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 36: Save Images

    Quality level 2: File size for full image region of interest 16 KB • Quality level 1: File size for full image region of interest 12 KB O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 37: Image Sequence

    • During the reading process for testing the configuration (Setup operating mode), the system shows the last 30 images captured. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 38: C32 Conversion

    CANopen heartbeat protocol stipulates that every CAN node must send out heartbeat objects at cyclical intervals and receive them from other bus participants. The transmis‐ sion cycle must be configured. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 39: Canopen Receive Pdos 1

    The CANopen protocol requires emergency objects to transmit error codes. The error codes are defined in communication profile DS-301 and in device profile DSP-40x. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 40: Cob-Id Rpdo User Dig. Input

    TPDO1 is used to signal the availability of data that can be retrieved by the service data object client (SDO client) via an SDO upload access. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 41: Codabar

    Spatial requirements: Largest possible number of characters per centimeter • Standard: ISO/IEC 15420 • Areas of application: All areas, as UCC 128/EAN 128 in retail 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 42: Code 128 Family

    • Intrinsic safety: Average • Spatial requirements: Low • Standard: ISO/IEC 16388 • Areas of application: Parcel and postal service O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 43: Code Appearance

    : Both dark codes on a light background and light codes on a dark background BOTH (inverted codes) are read. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 44: Code Info Box

    As only activated code types are processed, you can increase the processing speed by deactivating the code types that are not being used. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 45: Code Configuration

    FIXED lengths. Codes are only read if they feature one of these defined code lengths. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 46: Code Quality

    This keeps the reading operation focused on the code elements and reduces the decoding time. NOTE When the function is activated, poor quality codes tend to be ignored. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 47: Code Surrounded By Text

    1X and 8X wide • Intrinsic safety: High • Standard: ISO/IEC 2427 • Areas of application: Trade 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 48: Databar Expanded

    • Spatial requirements: Low • Standard: ISO/IEC 24727 • Areas of application: Trade and industry (pharmaceuticals industry and electronics sector) O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 49: Data Matrix

    8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 50: Data Source

    (e.g., low levels of contrast or when the code contains an error). • : The Balanced option accommodates applications that fall between the BALANCED two extremes. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 51: Default Gateway

    ). The stored images make it easy to identify potential causes of failure NO READ such as the deterioration of code markings. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 52: Log File Diagnosis Settings

    Object Trigger Control tab. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 53: Dot Size

    Intrinsic safety: High • Spatial requirements: Low • Standard: ISO/IEC 15417 • Areas of application: Identification of durable consumer goods 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 54: Ean

    • : The digital input responds to a permanently present signal according to how LEVEL Logic parameter is configured. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 55: Enable Diagnosis Output

    SOPAS commands constitute a command language that can be used to control the functions of the reading device and the object trigger control. A detailed list of the com‐ mands can be obtained from SICK on request. Debouncing Depending on how the...
  • Page 56: Allowed Characters / Scoring

    It is possible to select special characters or enter hexadecimal characters via the symbol. Information on editing the characters is available via the symbol. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 57: Separator Character Replacement

    If the Ethernet Aux parameter is activated, the results from the Ethernet aux interface are written to the save destination. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 58: Ethernet Aux Port

    Ethernet host interface. The Ethernet host interface is typically used for communication with the con‐ trol. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 59: Event Monitor

    : The output is activated if the code that has been read corre‐ TEACH-IN2 CONDITION sponds to the match code. TEACH-IN2 CONDITION 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 60 Length parameter are entered in mm. DISTANCE-CONTROLLED • : The values for the Length parameter are entered in ms. TIME-CONTROLLED O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 61: External Output 2

    : The output is activated if the code that has been read corre‐ TEACH-IN2 CONDITION sponds to the match code. TEACH-IN2 CONDITION 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 62 Length parameter are entered in mm. DISTANCE-CONTROLLED • : The values for the Length parameter are entered in ms. TIME-CONTROLLED O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 63: External Input

    If the value is not achieved, the signal is not detected. Depending on the application, this value may have to be adapted in line with the read cycle rates required. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 64: External Input 2

    EAN 128 code format. Up to three characters can be defined. The values must be entered as decimal num‐ bers. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 65: Fc1-Value Within Code

    By defining the specific symbol sizes that are permissible, you can restrict the range of codes to be read. This can lead to a reduction in the decoding time. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x...
  • Page 66: Fixed Size 3

    By defining the specific code lengths that are permissible, you can restrict the range of codes to be read. This can lead to a reduction in the decoding time. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 67: Filters/Sorters For Output Format

    You can also choose to sort the results in ascending or descending order. Example: : The codes with the shortest code length are output (CL) CODE LENGTH - ASCENDING first. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 68: Filter/Sorter For Output

    ) if the calculated check digit matches the one in GOOD READ the code. NOTE Check digits prevent codes from being misinterpreted and increase the reading reliabil‐ ity. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 69: Function

    SICK net‐ work in master/slave operating mode. • : The reading device is not integrated into a SICK network and operates STAND ALONE as a single device station in the system. The device communicates directly with the host.
  • Page 70: Function

    Given that the old parameter values are restored after the restart, this setting is suitable for testing parameter changes. This function can also be used if O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 71: Function Buttons

    ID is used as a CAN node for the CAN bus. NOTE If the device is connected to a SICK network via CAN, device IDs 1 to 63 can be assigned. If the device is connected to a CANopen fieldbus, device IDs 1 to 127 can be assigned.
  • Page 72: Device Name

    Speed parameter. To ensure a reliable connection, we recommend determining the speed of your directly connected PC automatically ( AUTO O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 73: Stored Images

    Good Read con‐ dition being met. The triggers involved in setting up the sensor are not included in the statistics. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 74: Green Feedback Spot

    The user-specific characters are entered via the keyboard or clipboard as hexadecimal values. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 75: Gs1 Databar

    Intrinsic safety: High • Spatial requirements: Low • Standard: DIN/EN 797 • Areas of application: Foodstuffs and consumer goods in Europe 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 76: Gtin 8 / Ean 8

    Brightness Range The minimum and maximum brightness values can be set using the slide control of the Brightness Range parameter. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 77: Brightness Tuning

    By activating this parameter, codes that are destroyed by the finger bars of the solar wafers can also be read. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x...
  • Page 78: Inactive

    They are also known as rotary encoders, incremental rotary encoders, and rotary pulse encoders. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 79: Increment Source

    The amount of internal memory available is 120 MB. The stored images can be trans‐ ferred to the PC and deleted manually. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 80: Internal Memory (Temporary)

    Ethernet host interface (default value: 2112) in line with the connected PC or control (PLC). O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 81: Iso15415 (Data Matrix)

    4 to 0. Calibration Pressing the Calibration button starts the image brightness calibration for the AIM DPM code evaluation. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 82: Camera And Illumination

    If several data telegrams are sent at the same time, the "With handshake" mode should be used to prevent data loss. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 83: Communication Mode

    : This mode is compatible with the data communication con‐ OPERATING MODE BMV10 cept of the SICK BMV10/BMH10 bus connection module. This means that the reading device is connected to a CDF600 Profibus proxy while other fieldbus nodes communicate via the BMV10 bus connection module. No output states are transferred.
  • Page 84: Coordinates

    By defining the specific code lengths that are permissible, you can restrict the range of codes to be read. This can lead to a reduction in the decoding time. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 85: Volume

    A larger reading distance increases the reading field. The resulting reduction in image brightness is compensated by means of the brightness control and, if nec‐ essary, by increasing the shutter time. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 86 In the case of codes created on metal, e.g., by dot peening, an angle of between 0° (bright field light) and 45° (dark field light) may be advisable. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 87: Mode To Send Readresult

    The unit can be selected via the Trigger delay parameter. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 88: Reading Gate Off

    Master / Slave Master / Slave group is used to configure the device as a node on a SICK network running in the master/slave operating mode. A maximum of 10 slaves can be con‐ nected to a master. The master sends the trigger signal to the slaves via the CAN bus at the start of the reading process.
  • Page 89: Match Code

    START WIZARD a node on a SICK network running in the master/slave operating mode. The wizard pro‐ vides the parameters required for configuring the CAN interface, device network func‐...
  • Page 90: Max. Storage Space (Mb)

    Measuring Region The measuring region for the brightness tuning is determined by changing the horizon‐ tal and vertical limits. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 91: Microsd Card

    (module width) that actually exists within the code. An average module width must be specified so that codes with varying module widths can still be read reliably. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 92: Minimum Cell Size

    O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 93: Mode

    : The device is integrated into a SICK network. On a SICK network, only SICK NETWORK SICK reading devices are networked via the CAN bus. This type of device group is used to scan an object from different perspectives and transmit the reading result to a host.
  • Page 94: Multiplexer / Server

    Multiplexer / Server Multiplexer / Server group is used to configure the device as a node on a SICK net‐ work running in the multiplexer/server operating mode. A maximum of 31 devices can be connected to a multiplexer as servers. The servers receive trigger signals for starting and ending the reading process via their respective photoelectric switches, which are connected to the digital input (sensor 1).
  • Page 95: Network / Interface / Ios

    • The CAN interface is used to integrate the device into a SICK network. On a SICK network, only SICK reading devices are networked via the CAN bus. This type of device group is used to scan an object from different perspectives and transmit the reading result to a host.
  • Page 96: Usage Plc-Input Bit1

    PLC outputs. As there is no opportunity to use triggers in the CMF400 commu‐ nication mode, instructions can be issued via the output properties. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 97: Object Trigger Control

    : A corresponding standard command for closing the reading gate is SOPAS COMMAND expected from a device such as an external control (PLC) (a detailed list of the commands can be obtained from SICK on request). • : The reading gate remains open for a defined time/distance (Read‐...
  • Page 98: Or Teach-In Via Function Buttons

    (e.g., on a network). O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 99: Length Of Output-Data

    You can use the SOPAS options (which are located outside of the device configuration) without logging in. Password protection is activated the next time the device is restarted. Password A password for the FTP image transfer to the SICK Visualization Platform is specified under the Password parameter.
  • Page 100: Pdf 417

    Standard: Laetus bar code standard • Areas of application: Packaging checks in the pharmaceutical industry (must match a reference code in a code list) O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 101: Port

    Port The port of the image server to which the images for the SICK Visualization Platform are to be sent is specified under the Port parameter.
  • Page 102: Profibus Proxy Cdf600

    PLC in bytes. Values can be specified between 8 and 500 bytes. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 103: Check Digit Test

    The unit can be selected via the Trigger delay parameter. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 104: Noise Reduction

    Heartbeat interval Heartbeat interval parameter is used to define the time between the heartbeat sig‐ nals in seconds. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 105: Allow Rectangular Data Fields

    To enable the sensor to read the plain text in a stable manner, the corresponding text properties must be set. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 106: Text Color

    Sensor / Input 2 Sensor / Input 2 group contains the parameters for adjusting digital input 2. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 107: Serial

    As the configuration of the interface cannot be changed on the sensor, the settings must be adapted on the connected device (e.g., PC or control). 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x...
  • Page 108: External Input Data

    SOPAS commands may continue to be sent to the sensor. It is recommended to use the default values for the headers Header) and terminators Terminator) of the received data. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 109: Serial Aux Interface

    (Heartbeat-Intervall) is that a signal is output via the interface. In this way, the availabil‐ ity of the sensor can be checked via the interface. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x...
  • Page 110: Service Information

    The SVP data output can be activated on the SICK Visualization Platform tab. The SVP (SICK Visualization Platform) is a dynamic database used to monitor, analyze, and evaluate all the information, including camera images and videos that are captured using automatic SICK data collection systems.
  • Page 111: Save Destination

    "stacked symbologies" (multiple bar codes that are stacked one on top of the other in rows and all have the same start and end characters). 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x...
  • Page 112: Transmit Start/Stop

    A, B, C, or D. If only identical start and stop characters are permitted, this increases the reading reliability and prevents codes from being misinterpreted. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 113: Start By

    : A corresponding command for opening the reading gate is SOPAS COMMAND expected from a device such as an external control (PLC). (A detailed list of the commands can be obtained from SICK on request.) • : The reading gate opens and closes automatically in accordance with a...
  • Page 114: Start Teach-In

    However, these settings reduce the reading reliability. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 115: Control System

    (stop bits) after a character has been transmitted. The set‐ ting must match the one on the host. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 116: Stop By

    : A corresponding standard command for closing the reading gate is SOPAS COMMAND expected from a device such as an external control (PLC) (a detailed list of the commands can be obtained from SICK on request). • : The reading gate remains open for a defined time/distance (Read‐...
  • Page 117: Stop Delay

    AUTHORIZED CUSTOMER The setting must be adjusted in line with the network. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 118: Beeper

    The SVP data output can be activated in the group. The SVP (SICK Visualization Platform) is a dynamic database used to monitor, analyze, and evaluate all the information, including camera images and videos that are captured using automatic SICK data collection systems.
  • Page 119: Symbol Size

    System status tab. This data is used to analyze the connections to the device and identify any system errors that occur. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 120: Teach-In Stop By

    If the reading diagnostic data is being monitored, the data is stored in the object direc‐ tory and downloaded by the control. A timeout must be specified for the upload. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 121: Condition Timeout

    SDO client. A timeout must be specified for the SDO client upload. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 122: Transmision Type

    If a time-controlled delay is set, the reading gate only opens once a predefined time has elapsed after the trigger sig‐ nal is issued. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 123: Tx Header

    : The reading device monitors other reading devices on the CAN bus. The device responsible for monitoring detects which nodes are available and which devices have dropped out. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 124: Ucc/Gs1-128 Emulation

    Spatial requirements: Low • Standard: DIN/EN 797 • Areas of application: Foodstuffs and consumer goods in the USA and Canada O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 125: Upc E

    COMPARISON WITH IDEAL CHARACTER calculated based on a comparison with this ideal character. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 126: Activate Iso15415 Verification

    Use Device-ID as Profibus-Address If the Use Device-ID as Profibus-Address parameter is activated, the device ID is used as a Profibus address. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 127: Delay

    The device must be restarted when the web server is activated for the first time. Angle The three-dimensional position of the camera is defined in the Angle group. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 128: Coordinate

    The user can initiate the first synchronization process using the button. RETRIEVE TIME FROM TIME SERVER O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 129 PC that should be used to store the captured images. 8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x Subject to change without notice...
  • Page 130 It is particularly recommended to activate this parameter when reading poor-quality, directly marked codes. Activating this additional error correction may affect the duration of the reading operation. O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK Subject to change without notice...
  • Page 131 Phone +386 (0)1-47 69 990 E-Mail ghk@sick.com.hk E-Mail office@sick.si Hungary South Africa Phone +36 1 371 2680 Phone +27 11 472 3733 More representatives and agencies E-Mail office@sick.hu E-Mail info@sickautomation.co.za at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

Table of Contents

Save PDF