SICK IDM series User Instructions

SICK IDM series User Instructions

Corded hand-held scanners
Hide thumbs Also See for IDM series:
Table of Contents

Advertisement

U S E R I N S T R U C T I O N S
IDMxxx corded
Hand-held Scanners

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDM series and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK IDM series

  • Page 1 U S E R I N S T R U C T I O N S IDMxxx corded Hand-held Scanners...
  • Page 2 Relevant for delivery with power supply. At the presence of high frequency interference in the frequency range of 15 MHz to 50 MHz there may be performance restrictions. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 3: Table Of Contents

    2.4.25  Netherland KIX Code, Intelligent Mail & Korea Post Code Settings ......43  2.5  Keyboard Interface Control ......................44  2.5.1  Keyboard Layout (Language) Settings................44  2.5.2  Record Suffix, Preamble, Postamble, FNC1 Transmit, Caps Lock........45  8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 4 Operation Mode Quick Set (IDM1xx series) .................. 81  3.7  Operation Mode Quick Set (IDM2xx series) .................. 82  3.8  Option Codes........................... 83  3.9  System Commands ......................... 84  © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 5: Getting Started

    USB is not suitable for use in industrial environments. Therefore, at cable installation it is important to ensure that there are no close sources of interference. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 6 If you want to use this cable for USB Com Port Mode, it is recommended to use an additional USB hub between cable and PC. The USB hub will boost the communication signal and secure the communication. If there is no power on Pin 6 or 9. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 7: Technical Specifications

    (www.mysick.com/en).                                                               Depending on scanner version (To be able to read stacked codes, PDF version is necessary). Optional via external SICK connection modules. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 8: Configuration

    “Cycling Scan Selection” or “Dual Level Selection” to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference. Please give careful attention to become familiar with each programming procedure. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 9: Program & End

    ASIC or non-volatile memory after you scan the “END”. Please don’t turn off the power before the completion beeping. It may destroy all configured parameters. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 10: System List & Master Default

    Select one option code for the desired codes parameter. Repeat Do you want to select another selection programming family? Scan Exit programming mode. „END“ © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 11: Multiple Scan Selection

    If it‘s necessary scan „FIN“ to terminate the option code selection. Repeat Do you want to select another selection programming family? Scan Exit programming mode. „END“ 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 12: Cycling Scan Selection

    “Multiple” scan selection. Scan “FIN” Finish cycling selection. (If necessary) Repeat Do you want to select another selection programming family? Scan Exit programming mode. „END“ © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 13: Dual Level Scan Selection

    ) Scan one or terminate the option code several option codes selection. Repeat Do you want to select another selection programming family? Scan Exit programming mode. „END“ 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 14: Host Interface Selection

    USB HID standard mode  USB HID turbo mode USB HID Legacy IDM2xx series doesn’t support Wand emulation, Laser emulation and USB HID Legacy © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 15: Symbology Reading Control

    PDF417/Micro PDF417 (default=V) (1 character) Codablock F (default=Y) (1 character) Code 16K (default=Q) (1 character) Code 49 (default=U) (1 character) Korea Post Code (default=a) (1 character) 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 16: Symbology Id Transmission

    Enable both prefix and suffix SICK symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 17: Readable Bar Code Setting

    Code 11 MSI/Plessey UK/Plessey Telepen GS1 DataBar (RSS-14) * IATA Coupon Code PDF417 * /Micro PDF417 Codablock F Code 16K Code 49 Korea Post Code 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 18 *. When you set the minimum and maximum length of each symbology, please note the data length of the scanned bar code doesn’t include start/stop characters. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 19: Code 39/ Code 32 Settings

    Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 20: Code 39 Settings

    Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 21: Codabar/ Nw-7 Settings

    Codabar Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 22: Upc-A/ Upc-E Settings

    Disable WPC Selection Basic With 2-digit With 5-digit Enable Enable Check Numeric (UPC/EAN/CAN) Length Addendum Addendum Standardization Expansion Digit System UPC-A UPC-E EAN-13 EAN-8 © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 23 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 24 UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select a higher level, it may impact the reading speed on poorly-printed, low contrast or damaged barcode labels. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 25: Ean Settings

    Level 2 Level 3  Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 Level 13 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 26 EAN with 2, or 5, or 2/5 supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 27: Ucc Coupon Extended Code Settings

    “5”, EAN-13 barcodes starting with digit “99” and GS1-128 Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 28: Iata & Interleaved 2 Of 5 Settings

    Select German Postal Code as primary format No check character  Validate USS check digit Validate OPCC check digit Disable check digit transmission  Enable check digit transmission © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 29: Code 25 Family Settings

    To decode all types of Code 25 or to variable length of Code 25 will increase the possibility of reading error. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 30: Code 11 & Code 93 Settings

    Code 39 Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 31: Msi/ Plessey Settings

    MSI/ Plessey Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 32: Code 128 Settings

    Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec." Code 128 bar codes. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 33: Gs1-128 Settings

    GS1-128 Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 34: Uk/ Plessey Settings

    UK/ Plessey Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 35: Telepen Settings

    Telepen Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 36: Gs1 Databar Settings

    Only available for Expanded GS1 DataBar. Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 37: Composite Codes, Codablock F, Pdf417, Micro Pdf417 Settings

    UPC barcodes are only transmitted when the Micro PDF417 is detected. Disable  Codablock F Settings Enable Disable PDF417 PDF417/ Micro PDF417 Settings Enable PDF417  Disable MicroPDF417  Enable MicroPDF417 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 38: Code 16K & Code 49 Settings

    Code 49 Max. Length 81-Minimum (2 digits) Scan 2 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 39: Qr Code Settings

    QR Code Max. Length 7089-Minimum (4 digits) Scan 4 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 40: Data Matrix Settings

    Data Matrix Max. Length 3116-Minimum (4 digits) Scan 4 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 41: Aztec Code Settings

    Aztec Code Max. Length 3832-Minimum (4 digits) Scan 4 digits from the option code chart in the Appendix; then the scanner will terminate this selection automatically. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 42: Autralian Post, Us Planet, Us Postnet, British Post, Japan Post Settings

    Australian Post Setting Auto-discriminate output option increases the risk of misread because the encoded data format does not specify the encoding table used for encoding. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 43: Netherland Kix Code, Intelligent Mail & Korea Post Code Settings

    (USPS 4CB/ One Code) Enable Intelligent Mail Disable Korea Post Code  Korea Post Code Settings Enable Korea Post Code Length fixed in 6 characters. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 44: Keyboard Interface Control

    Suffix Symbol ID Postamble Record Suffix 1-15 2-4 digits 1 or 3 characters Variable 1 or 3 characters 1-15 1 character characters length characters © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 45: Record Suffix, Preamble, Postamble, Fnc1 Transmit, Caps Lock

    The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 46: Delay Settings

    It is recommended to always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay: is a time delay of between transmission and reception of each segment of the message string. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 47: Emulation Settings, Key Pad Emulation, Upper/Lower Case Settings

    Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case) 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 48: Serial Interface Control

    Symbol ID Data Symbol ID Suffix 1-15 1 or 3 Variable 1 or 3 1-15 character characters digits characters length characters characters character character © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 49: Delay Settings

    It is recommended to always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay: is a time delay of between transmission and reception of each segment of the message string. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 50: Protocol, Ack/ Nak Settings

    NAKs from the host within the pre-set serial response time-out. This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disabled automatically. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 51: Response Time-Out, Baud Rate Settings

    The Serial Response Time-out is a pre-defined delay time for the Hand-held scanner to wait for handshaking, acknowledgment or non-acknowledgment from the host computer 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 52: Data Frame Settings

    8, None, 2 7, Odd, 1 7, Even, 1 7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 53: Wand/ Laser Emulation Control (Idm1Xx Series)

    Code 39 symbology set will be skipped. Code 39 Replace Any character not normally available in the standard Code 39 symbology set, will be translated as Space. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 54: Operation Control (Idm1Xx Series)

    “Light Source on Time” is reset. For you do not have to press the trigger frequently it is very convenient for multiple scanning. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 55 If there is no scanning operation performed during the pre-defined light source on time, the scanner enters the idle state after the pre-defined light source on time is up. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 56: Presentation Control, Scan Rate, Flash Duty

    But this may impact to the reading distance. Flash Duty Cycle The Flash Duty Cycle is designed to control the flashing frequency of the light source. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 57: 1D Barcode Reading Direction

    Disable  1D Barcode Direction Indication Transmission Enable prefix direction mark transmission Enable suffix direction mark transmission Enable both prefix and suffix direction mark transmission 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 58: Operation Control (Idm2Xx Series)

    LED illumination at a dim level. This is helpful to detect the motion of scene. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 59: Aiming Control, Delay Aiming, Decode Aiming Control

    The Delay Aiming Time-out Control is only available for trigger mode. You can use Delay Aiming Time-out Control to set the delay time. Decode Aiming Control For IDM260, this function is not supported in Hands-Free mode. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 60: Center Alignment, Unique Barcode Reporting

    When this function is enabled, the scanner only outputs unique barcodes when the trigger is pressed. This function is workable when Multiple Read mode is selected. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 61: Batch Reading

    Length: 2 byte You can find the SICK ID hex value in the Symbology ID Table in the appendix on page 77. Locate the Hex value for the symbology and scan the 2 digit hex values from the Option Codes.
  • Page 62 Code length that must match for Code 93, 9999 = all lengths 45464748 Start character match for Code 93, 45h = “E”, 46h = “F”, 47h = “G”, 48h = “H” End of third code © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 63 AIM Symbol interface) Length DataWizard interface) 1 character 1-15 1 or 3 Variable length 1 or 3 1-15 1 character characters digits characters characters characters 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 64: Operation Control (All Idm Series)

    IDM120 series doesn’t support this function. Disable Good Read Indicator Enable  Disable  Vibrator Control Enable  Only available for IDM160 and IDM260 series. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 65: Dollar Sign, Redundancy, 1D Code Inverse Reading

    The Redundancy is the number of times the same barcode has to be decoded before it is transmitted. (To prevent potential misreading.) Disable  1D Barcode Inverse Reading Enable  8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 66: Reread Delay, Good Read Delay Control

    IDM2xx: The Reread Delay function is only available in Multiple Read mode or when using the Hands- free stand. Good Read Delay This Good Read Delay is the minimum amount of time before the Hand-held scanner can read another barcode. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 67: Light Source On Time, Hands Free Time-Out

    This function sets the time for the scanner to enter low power mode after any scanning activity. This setting is only available if the scanner is in low power mode. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 68: Presentation Auto-Sense , Sensitivity

    The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting the barcode. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 69: Condensed Data Wizard

    . Through the IDM Set Up Tool, all settings and configurations can be done on-screen on Windows 2000 / XP / 7. A Condensed Version DataWizard is provided by each IDM series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease. All “Character” input should be referred to the ASCII/HEX Table listed in the Appendix (page 79) to find the matched HEX value.
  • Page 70: Data Formatter Settings

    75 for details. All “Character” input should be referred to the ASCII/HEX Table listed in the Appendix (page 79) to find matched HEX value. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 71: Data Verifier Settings

    2-digits checking position; 1   identified character Disable  3rd identified character Enable Position: (2 digits) [00-7F] DS  2-digits checking position; 1   identified character 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 72: Data Replacer Settings

    2-digits identified position; 1   replacement character Disable  3rd Replacement Enable Position: (2 digits) [00-7F] DS  2-digits identified position; 1   replacement character © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 73: Data Organizer Settings

    Transmitted data excluded the data of Include/ Exclude Control identified position  Transmitted data included the data of DS  identified position 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 74: Select A Barcode Symbology

    Micro QR Code Aztec Code Postal Codes Korea Post Code Japanese Post Australian Post KIX Post British Post Planet Post Intelligent Mail barcode Postnet © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 75: Position Calculation

    Scan “Identified Data Length” and set the length to “16”.  Scan “1st Identified Character” and set the identified position to “00”, then set the identified character to “39” (Hex Code of 9). 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 76 Therefore when you set the identified position in the Data organizer, you must consider the inserted data which you already set via Data Formatter. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 77: Appendix

    Code 49 PDF417 PDF417/ Micro PDF417 Codablock Codablock F Korea Post Korea Post Code Remark: Above examples are given for the transmission of AIM ID. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 78: Symbology Id Table (2D And Post Codes)

    Table which is for IBM PC/XT/AT, PS/2, PS/VP, COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 79: Ascii Input Shortcut (Reference Table)

    Scan the system command – FIN (Finish) to terminate Preamble setting.  Scan the system command – End to exit the programming mode for normal operation. 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 80: Host Interface Quick Set

    PS/2 (DOS/V) KBW Standard Mode   USB HID Standard Mode  Keyboard Replacement PS/2 (DOS/V) KB W Turbo Mode USB HID Turbo Mode USB Com Port Emulation © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 81: Operation Mode Quick Set (Idm1Xx Series)

    Alternative (Periodic Power off) Trigger (External Triggering) Toggle (Repeat reading)  Flash (Pulse driven reading) Presentation (Auto Sensing) Diagnostic (Test reading) Level (Auto power off) 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 82: Operation Mode Quick Set (Idm2Xx Series)

     Alternative (Periodic Power off) Trigger (External Triggering) Toggle (Repeat reading)  Level (Auto power off) Presentation (Auto Sensing) Diagnostic (Test reading) Multiple Read © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 83: Option Codes

    Option Codes User Instructions IDM corded Option Codes Abort FIN (Finish) END (Exit) 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 84: System Commands

    User Default: After scanning “Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and would like to return to previous setting, please scan “User Default”. © SICK AG · Germany · All rights reserved · Subject to change without notice 8015906/2013-07-02...
  • Page 85 System Commands User Instructions IDM corded 8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice...
  • Page 86 E-Mail support@sick.jp 1 (800) 325-7425 – tollfree Magyarország E-Mail info@sickusa.com Phone +36 1 371 2680 E-Mail office@sick.hu Nederlands Phone +31 (0)30 229 25 44 More representatives and agencies E-Mail info@sick.nl at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

Table of Contents