WCS position encoding system
Readers
Note!
The mounting bracket is identical for all readers.
12.5
Figure 5.3
5.2

Plastic Lenses

In the event of damage or contamination, you can replace the reader's plastic lenses.
Replacing the Plastic Lenses
1. Loosen two cross-head screws on each lens.
2. Remove the lens.
3. Slide the new lens into the intended position on the inside of the reader gap.
4. Secure the lens with the cross-head screws. The maximum torque is 0.8 Nm.
Tip
Always replace the lenses in pairs and also replace the seals.
The plastic lenses are available in pairs as spare parts.