8 COMMISSIONING INSTRUCTIONS

Once the appliance has been installed correctly, it must be prepared for use:
Fill up with regenerating salt.
Add detergent and neutralising agent and any other chemicals.
8.1

USING THE WATER SOFTENER

The appliance is equipped with a water softener which removes the substances that cause hardness from the inlet
water.
fig. 14 – The salt tank is accessible with the door open; filling the softener tank with regenerating salt.
The softener tank contains about 1 kg of coarse salt. The salt tank is in the bottom of the inside of the well. Remove the bottom
basket, unscrew the cap of the tank by turning it anticlockwise and pour in the salt using the funnel supplied; take care not to spill
salt in the tank. Remove any salt residues before screwing the cap back on.
ATTENTION
The first time the device is used, a litre of water must be poured into the tank with the salt. Whenever the tank is filled,
always take care to ensure that the cap is firmly closed. The mixture of water and detergent must not get into the salt
tank, as this would impair operation of the regeneration resins.
Only use coarse salt for domestic dishwashers. Do not use cooking salt.
Fill up with salt when necessary before starting a washing program, so that any excess salt solution will immediately be
removed; if salt water is left to stand inside the tank, it may cause corrosion. Carry out a prewash cycle to prevent this if
necessary.
8.2

USING DETERGENTS

One fundamental factor for a good washing process is the type of detergents used.
The manufacturer guarantees excellent washing results with the use of the recommended products.
The device is equipped with automatic detergent dispensing devices.
DISPENSING
STD DEVICE
DEVICE
P1
P2
P3
P4
 (90cm
P5
models only)
Key:  feature installed,  optional feature, - feature not available for installation
ATTENTION
If the can level sensors are not fitted: check the levels of product in the cans / bottles to ensure that programs are not
performed without detergent or neutralising agent.
Always comply with the INSTRUCTIONS provided by detergent PRODUCERS, especially with regard to the
RECOMMENDED DOSES, the correct TEMPERATURES for their use and STORAGE instructions. Safety information about
doses supplied in compliance with 5.4.4.s of IEC61010-2-040. Refer to the product instructions and technical safety data
sheets.
8.2.1

LIQUID DETERGENT INTAKE SYSTEM

Standard Configuration, with LEVEL SENSOR. Intake nozzle with integral:
Level sensor and support for fitting onto the can.
High-strength rubber hose for connection between intake pipe and peristaltic pump.
Detergent intake filter, fitted directly on the suction nozzle pipe.
WD3060 - WD5090
USE OF DEVICE AS HOSPITAL
INSTRUMENTS WASHER
neutral or weak alkaline liquid detergent
acid neutralising agent
additional disinfectant detergent
lubricant
additional detergent
USER MANUAL
USE OF DEVICE AS GLASSWARE
WASHER
neutral or weak alkaline liquid
detergent
acid neutralising agent
NaOH 33%
antifoam
additional detergent
18