Fault finding and diagnosis
8.2
Component resistance characteristics
8.2.1
Flow temperature NTC sensor
Temperature ( °C)
Resistance ( )
Measurement tolerance 10%
35,975
28,516
22,763
18,279
14,772
11,981
9,786
8,047
6,653
5,523
4,608
3,856
3,243
2,744
2,332
1,990
1,704
1,464
1,262
1,093
950
Table 50 Central heating flow sensors
8.2.2
DHW NTC sensor
Temperature ( °C)
Resistance ( )
Measurement tolerance 10%
36,005
28,540
22,782
18,294
14,785
11,991
9,794
8,054
6,658
5,527
4,612
3,859
3,246
2,747
2,334
1,991
1,705
1,465
1,263
1,094
951
Table 51 Domestic hot water sensors
70
8.2.3
Normally closed thermostat
Opening temperature
Close temperature
0
5
Table 52 Flue overheat thermostat
10
8.2.4
15
Normally closed thermostat
20
Opening temperature
25
Close temperature
30
Table 53 Overheat thermostat
35
40
8.2.5
Resistance ( )
45
50
55
60
65
70
75
80
85
90
95
100
0
5
10
15
Table 54 Outdoor weather compensation sensor
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Flue overheat thermostat
Resistance ( ) Temperature ( °C)
3,500
6,500
Overheat thermostat
Resistance
50M
5,000
Outdoor weather compensation sensor
Temperature ( °C)
4,111
3,669
3,218
2,775
2,360
1,983
1,650
1,363
1,122
922
759
624
515
427
354
296
247
207
174
Greenstar i System
112
111
Temperature ( °C)
120
119
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
50
- 6 720 806 945 (2015/07)