Energy Efficiency - Worcester Greenstar i System ErP Series Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing system boiler
Table of Contents

Advertisement

Appliance information
3.3

Energy efficiency

Natural Gas appliances
The following product data satisfy the requirements of the EU Regulations No. 811/2013 and No. 812/2013 supplementing Directive 2010/30/EU.
Product data
Symbol
Product type
Condensing boiler
Low temperature boiler
B1 boiler
Cogeneration space heater
(CHP)
Combination heater
Rated heat output
P
rated
Seasonal space heating
energy efficiency
Energy efficiency class
Useful heat output
At rated heat output and
1)
high temperature regime
At 30 % of rated heat output
and low temperature
2)
regime
Useful efficiency
At rated heat output and
1)
high temperature regime
At 30 % of rated heat output
and low temperature
2)
regime
Auxiliary electricity consumption
At full load
el
At part load
el
In standby mode
P
Other items
Standby heat loss
P
Ignition burner power
P
consumption
Emissions of nitrogen
NOx
oxides
Sound power level, indoors
L
Table 6 Product data for energy efficiency in accordance with Regulation (EU) no. 813/2013
1) High temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
10
Unit
7733600011 7733600010 7733600009 7733600008 7733600007 7733600006
9i System
ErP
NG
Yes
No
No
No
No
kW
9
%
93
s
A
P
kW
9
4
P
kW
3
1
%
88.2
4
%
99.5
1
kW
0.025
max
kW
0.014
min
kW
0.002
SB
kW
0.058
stby
kW
0
ign
mg/kWh
32
dB(A)
49
WA
12i System
15i System
ErP
ErP
NG
NG
Yes
Yes
No
No
No
No
No
No
No
No
12
15
94
94
A
A
12
15
4.1
5.1
88.2
87.9
99.5
99.3
0.038
0.033
0.014
0.014
0.002
0.002
0.058
0.058
0
0
41
38
52
50
18i System
21i System
ErP
ErP
NG
NG
Yes
Yes
No
No
No
No
No
No
No
No
18
21
94
94
A
A
18
21
6.2
7.2
87.9
87.7
99.3
99.4
0.047
0.033
0.014
0.014
0.002
0.002
0.058
0.058
0
0
45
44
52
49
Greenstar i System
- 6 720 806 945 (2015/07)
ErP
24i System
ErP
NG
Yes
No
No
No
No
24
94
A
24
8.2
87.7
99.4
0.039
0.014
0.002
0.058
0
44
50

Advertisement