  • Page 1 BEETLE /iSCAN EASY Non Cash Installation manual May 2019 01750249243E...
  • Page 2 Copyright © Diebold Nixdorf All rights, including rights of translation, reproduction by printing, copying or similar methods, in part or in whole, are reserved. Any violations give rise to a claim for damages. All rights reserved, particularly in relation to the grant of a patent or the registration of a utility model.
  • Page 3: Table Of Contents

    Contents About this Manual ........................1 Further Documentation ......................1 Warranty ............................ 2 ESD (Electrostatic Sensitive Devices) ..................2 Important Notes ......................... 3 Connecting Peripherals ......................4 Customer Requirements ......................5 Components ..........................6 Unpacking and Checking the System ..................7 Installing the BEETLE /iSCAN EASY in the Store .................
  • Page 4 Certificates ..........................44 CE Marking ......................... 44 CSA ............................. 44 FCC-Class A Declaration ..................... 44 3 0 B R ecycling the BEETLE /iSCAN EASY ..................44...
  • Page 5: About This Manual

    BEETLE /iSCAN EASY. Further safety, installation, and maintenance instructions can be found in the manuals supplied with the components. In case of doubts or questions please contact Diebold Nixdorf. Further Documentation Find the „User Manual“ (Hardware) on the Diebold Nixdorf Internet.
  • Page 6: Warranty

    Warranty Warranty Diebold Nixdorf generally guarantees a warranty engagement for 12 months beginning with the date of delivery. This warranty engagement covers all damages which occur despite a normal use of the product. Damages because of improper or insufficient maintenance, ...
  • Page 7: Important Notes

    Important Notes Important Notes Appliances supplied by Diebold Nixdorf comply with the respective safety regulations for data- processing installations and information technology installations, including electrical office equipment for use within an office environment. Whenever work of any kind is done on the device, as well as when data cables are plugged and unplugged, the device must be completely disconnected from the line voltage.
  • Page 8: Connecting Peripherals

    Connecting Peripherals Use only shielded cables when connecting devices to the system to ensure compliance with international Rules and Regulations for radiated emission as well as to achieve a high immunity against external disturbances. BEETLE /iSCAN EASY Non Cash...
  • Page 9: Customer Requirements

    The customer is responsible for relocating the Self-Checkout equipment (check stand and components) to the final placement/installation position. Keep the Diebold Nixdorf equipment area free from dust, smoke, lint, and other particles. Restrict smoking, eating, and drinking around the equipment. Avoid locating the equipment near other machines that generate ink, carbon and paper dust particles.
  • Page 10: Components

    Customer Requierements Components BEETLE /iSCAN EASY Non Cash...
  • Page 11: Unpacking And Checking The System

     functional defects,  please inform your contracting parties or the branch office of Diebold Nixdorf immediately. Please indicate the number of your delivery ticket and delivery ticket position and serial number of the respective device. We recommend to keep the original packaging for transport at a later time (protection from impact and shock).
  • Page 12: Installing The Beetle /Iscan Easy In The Store

    Caution! Always wear safety gloves and safety shoes with steel toe caps while transporting heavy appliances. USA: Safety shoes with class 1 toe cap according ASTM F 2412 and ANSI Z41.1 in its current versions. Canada: Protection CSA code 1Pxxx. Unlock the system and open the door. BEETLE /iSCAN EASY Non Cash...
  • Page 13 Installing the Pole Light Remove the two screws near the front (see arrows). Remove two screws (see arrows) and remove the back cover upwards. BEETLE /iSCAN EASY Non Cash...
  • Page 14: Delivery Unit

    Ensure that the installation site has the required load-carrying capacity. Delivery Unit 01750252991 Screw kit for floor mounting 01750009782 ROTOR 01750097998 Hexagon head screw DIN 933 M10x60-8.8 3587100020 Washer 10,5x2,0mm 4330700428 Minigrip Poly-Bag 100 x 150mm BEETLE /iSCAN EASY Non Cash...
  • Page 15: Drill Template Beetle /Iscan Easy With Socket

    Installing the Pole Light The following drill template has to be used to fix the BEETLE /iSCAN EASY on the floor. Drill Template BEETLE /iSCAN EASY with Socket All dimensions in mm BEETLE /iSCAN EASY Non Cash...
  • Page 16: Drill Template Beetle /Iscan Easy Without Socket

    Drill Template BEETLE /iSCAN EASY without Socket All dimensions in mm Set the back cover in the snap hooks at the BEETLE /iSCAN EASY housing (see arrows). Set the back cover into place and fix it with the screws removed before. BEETLE /iSCAN EASY Non Cash...
  • Page 17: Installing The Standard Pole Light

    Unwrap the pole light and deposit it in a save place. The installation might be easier when you uninstall the visual protection before. Tilt the display upwards to the position as shown in the picture below. Remove the screw which fixes the speaker box. BEETLE /iSCAN EASY Non Cash...
  • Page 18 Installing the Pole Light Lift the speaker box upwards and remove it forwards (see arrows). Unplug the speaker cable. Remove the two screws fixing it at the holder. BEETLE /iSCAN EASY Non Cash...
  • Page 19 Remove the display upwards and place it beside the printer. Remove four screws (see arrows) from the holder. Remove (see arrow) the back side from the front side of the pole light. Front side – do not remove! BEETLE /iSCAN EASY Non Cash...
  • Page 20 Push the two tins holder as shown in the picture to the front side of the pole light. Mount the front cover to the holder and secure it with the four screws removed before. Plug the cable. BEETLE /iSCAN EASY Non Cash...
  • Page 21 If you choose the lower position, remove the plate below (remove two screws – see arrows) and mount it in the upper position. Upper Position Set the display into place and fix it with the two screws removed before. BEETLE /iSCAN EASY Non Cash...
  • Page 22 Installing the Pole Light Lay the cables inside the pole light in the position as shown in the foolowing pictures and fix them with the tin plates (see black arrows). BEETLE /iSCAN EASY Non Cash...
  • Page 23 Place the rear profile with the right side (as viewed from the back of the ACO) into the groove of the fixed profile. Using both hands, squeeze the two profile pieces together until they click into place. BEETLE /iSCAN EASY Non Cash...
  • Page 24: Installing The Ada-Ii Pole Light

    Set the front side of the pole light (side with the drillings) into place and fix it with a screw Tx20 at both sides from the display. Fix the pole light additional with the two holders. Set the holder into place as shown in the picture below. BEETLE /iSCAN EASY Non Cash...
  • Page 25 Fix the holders at first with a screw at the housing of the self checkout (1). Fix the holders also at the pole light (2). Plug the cable (fits just in one position) and set the back cover into place (just clip it in). BEETLE /iSCAN EASY Non Cash...
  • Page 26: Installing The Security Scale

    In such cases, tests with various parameters can be carried out on-site.  Special parameter programs are available for this purpose (please contact Diebold Nixdorf  Service). Wind and air currents can also cause false values (the scale may not be located within the ...
  • Page 27: Installing

    Caution! Always wear safety gloves and safety shoes with steel toe caps while transporting heavy appliances. USA: Safety shoes with class 1 toe cap according ASTM F 2412 and ANSI Z41.1 in its current versions. Canada: Protection CSA code 1Pxxx. BEETLE /iSCAN EASY Non Cash...
  • Page 28 The screws to fix the security scale are already installed in the right position in the BEETLE /iSCAN EASY. Loosen the screws for the security scale at the side cover of the BEETLE /iSCAN EASY. Mount the security scale and push the device backwards. Fix the screws. BEETLE /iSCAN EASY Non Cash...
  • Page 29: Connecting The System

    The BEETLE /iSCAN EASY terminal provides a female RJ-45 connection port for the LAN. A 6-foot LAN cable is provided with the system. Plug in the power and the LAN cable at the back side of the device. BEETLE /iSCAN EASY Non Cash...
  • Page 30 Connecting the System Mount the cover with two screws. Unlock and open the front door of the BEETLE /iSCAN EASY. BEETLE /iSCAN EASY Non Cash...
  • Page 31: Disconnecting The System From The Mains

    Start the system by switching the switch to position »1« (see arrow). Disconnecting the System from the Mains Shut down the system by the software application.  Disconnect the system by pressing the button in position 0 (see picture above).  Unplug the power supply.  BEETLE /iSCAN EASY Non Cash...
  • Page 32: Cleaning Instructions

     Wrong maintenance may cause damages to the screen, which are not covered by warranty. Approved Cleaning Materials The items listed below can be ordered from Diebold Nixdorf branch office or your Diebold Nixdorf sales partner. Product Name Order Number...
  • Page 33: No Security Scale

    Appendix Dimensions No Security Scale BEETLE /iSCAN EASY Non Cash...
  • Page 34 Appendix BEETLE /iSCAN EASY Non Cash...
  • Page 35: One Bag Security Scale

    Appendix One Bag Security Scale BEETLE /iSCAN EASY Non Cash...
  • Page 36 Appendix BEETLE /iSCAN EASY Non Cash...
  • Page 37: Two Bags Security Scale Lenghtwise

    Appendix Two Bags Security Scale lenghtwise BEETLE /iSCAN EASY Non Cash...
  • Page 38 Appendix BEETLE /iSCAN EASY Non Cash...
  • Page 39: Two Bags Security Scale Across

    Appendix Two Bags Security Scale across BEETLE /iSCAN EASY Non Cash...
  • Page 40 Appendix BEETLE /iSCAN EASY Non Cash...
  • Page 41: Four Bags Security Scale

    Appendix Four Bags Security Scale BEETLE /iSCAN EASY Non Cash...
  • Page 42 Appendix BEETLE /iSCAN EASY Non Cash...
  • Page 43: Block Diagram

    Appendix Block Diagram BEETLE /iSCAN EASY NON CASH BEETLE /M-III BEETLE /iSCAN EASY Non Cash...
  • Page 44 Appendix BEETLE /iSCAN EASY NON CASH BEETLE /M-II plus BEETLE /iSCAN EASY Non Cash...
  • Page 45: Technical Data

    Printer (receipt,MF,coupon) Customer interaction 15" LCD touch; wide screen and 2nd customer display (optional) Speaker integrated Proximity sensor (optional) Illumination for input and output slots System unit System • BEETLE /M-III • BEETLE /M-II plus BEETLE /iSCAN EASY Non Cash...
  • Page 46 Attendant Logon • Via dallas key or barcode • Alternatives possible Status Lights EAS deactivation (optional} Ratings 100 V-120 V  200 V-240 V  2.0 A / 1.0 A / 50 Hz -60 Hz  BEETLE /iSCAN EASY Non Cash...
  • Page 47: Environmental Conditions

    EN 60721-3-2; Class 2k2 Climate test according to IEC 68 / EN60068 Ambient temperature: -25 °C – 60 °C Humidity: 15% r.h. (1 g/m ) – 98% r.h. (32 g/m Temperature change: -25 °C / 25 °C BEETLE /iSCAN EASY Non Cash...
  • Page 48 This class A digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe A est conforme à la norme NMB-003 du Canada. 3 0 B BEETLE /iSCAN EASY Non Cash...
  • Page 49 For recycling purposes do not attach any additional adhesive labels to the device. Diebold Nixdorf disposes of old devices in a environmentally responsible manner at a recycling center that is ISO 9001 and ISO 14001 certified, as is the entire company.
  • Page 50 Diebold Nixdorf D-33094 Paderborn Order No.: 01750249243E...