  • Page 1 DN Series 250 Installation Manual 01750340327 B...
  • Page 2 This document and the information contained herein are provided AS IS AND WITHOUT WARRANTY. In no event shall Diebold Nixdorf or its suppliers be liable for any special, indirect, or consequential dam- ages of any nature resulting from the use of information in this manual. The information contained in this document is subject to change without notice.
  • Page 3: Table Of Contents

    Mounting set 01750051579 for installation plinth with CEN I/III/IV safe ..... 4-4 Notes concerning installation .....................4-5 Preparing for installation ....................4-6 4.3.1 Removing transport packing ................4-6 4.3.2 Removing the shipping crate ................4-7 Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 4 6 Appendix............................. 6-1 Check list for installation preparations for self-service systems.........6-1 Technical Data ........................6-7 6.2.1 General installation conditions ................6-7 6.2.2 Environmental conditions ..................6-10 Compliance with Standards and Approvals ...............6-11 Environmental Protection ....................6-13 Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 5 System dimensions with 5K CEN safe, max. 360 mm (14.17") wall thickness and UPS .........................3-26 Figure 3-26 System dimensions with 5K CEN safe, max. 360 mm (14.17") wall thickness, at- tached logo case and UPS..................3-27 Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 6 Positioning of the installation plinth in relation to the wall with CEN safe and and wall thickness max. 360 mm (14.17")..............3-55 Figure 3-53 Positioning of the installation plinth 120 mm / 191 mm (4.72" / 7.52") to the wall, UL safe, wall thickness max. 203 mm (7.99") ............3-56 Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 7 Aligning installation with the installation plinth system ...........4-19 Figure 4-17 Installation without installation plinth – Tightening the cable clamps .....4-20 Figure 4-18 Sealing the bottom edges of the safe..............4-20 Figure 4-19 Laying cables from the side - Remove filler ............4-21 Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 8 Securing the upper side of the sealing frame............4-60 Figure 4-56 Securing the underside of the sealing frame............4-60 Figure 4-57 Securing the sealing frame..................4-61 Figure 4-58 Position the side piece on the right ................4-61 Copyright © 2020, Diebold Nixdorf viii 01750340327 B...
  • Page 9 Screwing the cover plates to the wall ..............4-66 Figure 4-68 Secure the rear of Mounting set DS5550 / Opteva 562 .........4-66 Figure 4-69 Drilling and securing the rear of Mounting set DS5550 / Opteva 562 ....4-67 Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 10 Example assignment of USB cables to the customer connection box ....4-34 Table 6-1 Electrical characteristics..................6-7 Table 6-2 Installation specifications..................6-9 Table 6-3 Heat dissipation......................6-10 Table 6-4 Climatic environmental conditions according to EN 60721 ........6-10 Table 6-5 Noise rating ......................6-10 Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 11: Introduction

    – CEN I, CEN III, CEN IV, CEN III EXGas, CEN IV EXGas safe The following accessories are available: • Remote Status Indicator (RSI) : – RSI - Standard – RSI - Audio Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 12: Symbols Used In This Manual

    Prerequisite that must be fulfilled before an action. Numbered instructions describe activities which must be carried out in the specified se- quence Intermediate result of an action. Action successfully completed. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 13: Signs, Markings And Symbols

    Table 1-2: Mandatory Signs Used Mandatory Signs Wear Wear Wear Wear ear protection eye protection foot protection hand protection Pull Observe main plug the manual Prohibition signs Climb forbidden Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 14: Section-Specific Warning Notes

    This warning note describes a hazard with a low degree of risk which, if not avoided, could result in slight or minor bodily injury. NOTE This note provides application tips and information that help prevent errors and material damage. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 15: Safety

    • For reasons of stability, the system must be screwed to the load-bearing substructure of the installa- tion site or mounted on a suitable base. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 16 (e.g. EMA connection), only safety extra-low voltage circuits (ES1 circuits) are involved. • To clean the system only use cleaning agents approved by Diebold Nixdorf (see chapter "Cleaning, Service and Maintenance" in the operating manual). Copyright © 2020, Diebold Nixdorf...
  • Page 17 Do not allow the battery to come into contact with water or fire The battery should only be replaced with the same or an equivalent type recom- mended by Diebold Nixdorf (see chapter “Appendix,” section “Consumables” in the operating manual). Dispose of used batteries in compliance with national regulations and the manufacturer's specifications.
  • Page 18: Notes Concerning Installation

    (see enclosed information sheet). Radio Interference WARNING This is a Class A product; it can cause radio interference in residential areas. The operator may be obligated to implement suitable measures in such cases. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 19: General Power Interruption

    Alternatively, the power supply can be interrupted by switching off the circuit-breaker or removing the fuse from the distributor box of the facility in- stallation. Figure 2-2: General power interruption - Disconnecting the plug Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 20 3 Planning the installation This chapter provides you with all the information you need to prepare the installation. NOTE All dimensions are specified in millimeters (and inches). The system views are not drawn to scale. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 21: Dimensions

    Some dimensions may differ due to the shipping rack used (see following illustrations). 4K UL safe with a maximum wall thickness of 203 mm (7.99") Figure 3-1: Transport dimensions with 4K UL safe, max. 203 mm (7.99") wall thickness Shipping rack Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 22: Figure 3-2 Transport Dimensions With 4K Ul Safe, Max. 360 Mm (14.17") Wall Thickness

    Planning the installation 4K UL safe with a maximum wall thickness of 360 mm (14.17") Figure 3-2: Transport dimensions with 4K UL safe, max. 360 mm (14.17") wall thickness Shipping rack Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 23: Figure 3-3 Transport Dimensions With 4K Cen Safe, Max. 203 Mm (7.99") Wall Thickness

    Planning the installation 4K CEN safe with a maximum wall thickness of 203 mm (7.99") Figure 3-3: Transport dimensions with 4K CEN safe, max. 203 mm (7.99") wall thickness Shipping rack Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 24: Figure 3-4 Transport Dimensions With 4K Cen Safe, Max. 360 Mm (14.17") Wall Thickness

    Planning the installation 4K CEN safe with a maximum wall thickness of 360 mm (14.17") Figure 3-4: Transport dimensions with 4K CEN safe, max. 360 mm (14.17") wall thickness Shipping rack Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 25: Figure 3-5 Transport Dimensions With 5K Ul Safe, Max. 203 Mm (7.99") Wall Thickness

    Planning the installation 5K UL safe with a maximum wall thickness of 203 mm (7.99") Figure 3-5: Transport dimensions with 5K UL safe, max. 203 mm (7.99") wall thickness Shipping rack Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 26: Figure 3-6 Transport Dimensions With 5K Ul Safe, Max. 306 Mm (14.17") Wall Thickness

    Planning the installation 5K UL safe with a maximum wall thickness of 360 mm (14.17") Figure 3-6: Transport dimensions with 5K UL safe, max. 306 mm (14.17") wall thickness Shipping rack Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 27: Figure 3-7 Transport Dimensions With 5K Cen Safe, Max. 203 Mm (7.99") Wall Thickness

    Planning the installation 5K CEN safe with a maximum wall thickness of 203 mm (7.99") Figure 3-7: Transport dimensions with 5K CEN safe, max. 203 mm (7.99") wall thickness Shipping rack Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 28: Figure 3-8 Transport Dimensions With 5K Cen Safe, Max. 360 Mm (14.17") Wall Thickness

    Planning the installation 5K CEN safe with a maximum wall thickness of 360 mm (14.17") Figure 3-8: Transport dimensions with 5K CEN safe, max. 360 mm (14.17") wall thickness Shipping rack Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 29: Figure 3-9 Transport Route For Cen Safe, Maximum Wall Thickness Of 203 Mm (7.99")

    3.94")) you can draw the actual dimensions of the door and the hallway to find out if there is enough space for transportation. Refer to the next page for an example. Figure 3-9: Transport route for CEN safe, maximum wall thickness of 203 mm (7.99") Copyright © 2020, Diebold Nixdorf 3-10 01750340327 B...
  • Page 30: Figure 3-10 Transport Route For Cen Safe, Maximum Wall Thickness Of 360 Mm (14.17")

    3.94")) you can draw the actual dimensions of the door and the hallway to find out if there is enough space for transportation. Refer to the next page for an example. Figure 3-10: Transport route for CEN safe, maximum wall thickness of 360 mm (14.17") Copyright © 2020, Diebold Nixdorf 3-11 01750340327 B...
  • Page 31: System Dimensions

    4K UL safe without attached logo case, with UPS, with a max. wall thickness of 203 mm (7.99") Figure 3-11: System dimensions with UL safe, max. 203 mm (7.99") wall thickness and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-12 01750340327 B...
  • Page 32: Figure 3-12 System Dimensions With Ul Safe, Max. 203 Mm (7.99") Wall Thickness, Attached Logo Case And Ups

    4K UL safe with attached logo case, with UPS, with a max. wall thickness of 203 mm (7.99") Figure 3-12: System dimensions with UL safe, max. 203 mm (7.99") wall thickness, attached logo case and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-13 01750340327 B...
  • Page 33: Figure 3-13 System Dimensions With Ul Safe, Max. 360 Mm (14.17") Wall Thickness And

    4K UL safe without attached logo case, with UPS, with a max. wall thickness of 360 mm (14.17") Figure 3-13: System dimensions with UL safe, max. 360 mm (14.17") wall thickness and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-14 01750340327 B...
  • Page 34: Figure 3-14 System Dimensions With Ul Safe, Max. 360 Mm (14.17") Wall Thickness, At- Tached Logo Case And Ups

    4K UL safe with attached logo case, with UPS, with a max. wall thickness of 360 mm (14.17") Figure 3-14: System dimensions with UL safe, max. 360 mm (14.17") wall thickness, attached logo case and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-15 01750340327 B...
  • Page 35: Figure 3-15 System Dimensions With Cen Safe, Max. 203 Mm (7.99") Wall Thickness And

    4K CEN safe without attached logo case, with UPS, with a max. wall thickness of 203 mm (7.99") Figure 3-15: System dimensions with CEN safe, max. 203 mm (7.99") wall thickness and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-16 01750340327 B...
  • Page 36: Figure 3-16 System Dimensions With Cen Safe, Max. 203 Mm (7.99") Wall Thickness, At- Tached Logo Case And Ups

    4K CEN safe with attached logo case, with UPS, with a max. wall thickness of 203 mm (7.99") Figure 3-16: System dimensions with CEN safe, max. 203 mm (7.99") wall thickness, attached logo case and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-17 01750340327 B...
  • Page 37: Figure 3-17 System Dimensions With Cen Safe, Max. 360 Mm (14.17") Wall Thickness And

    4K CEN safe without attached logo case, with UPS, with a max. wall thickness of 360 mm (14.17") Figure 3-17: System dimensions with CEN safe, max. 360 mm (14.17") wall thickness and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-18 01750340327 B...
  • Page 38: Figure 3-18 System Dimensions With Cen Safe, Max. 360 Mm (14.17") Wall Thickness, At- Tached Logo Case And Ups

    4K CEN safe with attached logo case, with UPS, with a max. wall thickness of 360 mm (14.17") Figure 3-18: System dimensions with CEN safe, max. 360 mm (14.17") wall thickness, attached logo case and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-19 01750340327 B...
  • Page 39: Figure 3-19 System Dimensions With 5K Ul Safe, Max. 203 Mm (7.99") Wall Thickness And

    5K UL safe without attached logo case, with UPS, with a max. wall thickness of 203 mm (7.99") Figure 3-19: System dimensions with 5K UL safe, max. 203 mm (7.99") wall thickness and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-20 01750340327 B...
  • Page 40: Figure 3-20 System Dimensions With 5K Ul Safe, Max. 203 Mm (7.99") Wall Thickness, At- Tached Logo Case And Ups

    3.1.2.10 5K UL safe with attached logo case, with UPS, with a max. wall thickness of 203 mm (7.99") Figure 3-20: System dimensions with 5K UL safe, max. 203 mm (7.99") wall thickness, attached logo case and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-21 01750340327 B...
  • Page 41: Figure 3-21 System Dimensions With 5K Ul Safe, Max. 360 Mm (14.17") Wall Thickness And

    3.1.2.11 5K UL safe without attached logo case, with UPS, with a max. wall thickness of 360 mm (14.17") Figure 3-21: System dimensions with 5K UL safe, max. 360 mm (14.17") wall thickness and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-22 01750340327 B...
  • Page 42: Figure 3-22 System Dimensions With 5K Ul Safe, Max. 360 Mm (14.17") Wall Thickness, At- Tached Logo Case And Ups

    3.1.2.12 5K UL safe with attached logo case, with UPS, with a max. wall thickness of 360 mm (14.17") Figure 3-22: System dimensions with 5K UL safe, max. 360 mm (14.17") wall thickness, attached logo case and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-23 01750340327 B...
  • Page 43: Figure 3-23 System Dimensions With 5K Cen Safe, Max. 203 Mm (7.99") Wall Thickness And

    3.1.2.13 5K CEN safe without attached logo case, with UPS, with a max. wall thickness of 203 mm (7.99") Figure 3-23: System dimensions with 5K CEN safe, max. 203 mm (7.99") wall thickness and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-24 01750340327 B...
  • Page 44: Figure 3-24 System Dimensions With 5K Cen Safe, Max. 203 Mm (7.99") Wall Thickness, At- Tached Logo Case And Ups

    3.1.2.14 5K CEN safe with attached logo case, with UPS, with a max. wall thickness of 203 mm (7.99") Figure 3-24: System dimensions with 5K CEN safe, max. 203 mm (7.99") wall thickness, attached logo case and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-25 01750340327 B...
  • Page 45: Figure 3-25 System Dimensions With 5K Cen Safe, Max. 360 Mm (14.17") Wall Thickness And Ups

    3.1.2.15 5K CEN safe without attached logo case, with UPS, with a max. wall thickness of 360 mm (14.17") Figure 3-25: System dimensions with 5K CEN safe, max. 360 mm (14.17") wall thickness and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-26 01750340327 B...
  • Page 46: Figure 3-26 System Dimensions With 5K Cen Safe, Max. 360 Mm (14.17") Wall Thickness, At- Tached Logo Case And Ups

    3.1.2.16 5K CEN safe with attached logo case, with UPS, with a max. wall thickness of 360 mm (14.17") Figure 3-26: System dimensions with 5K CEN safe, max. 360 mm (14.17") wall thickness, attached logo case and UPS Installation plinth 25 mm (0.99") (optional) Copyright © 2020, Diebold Nixdorf 3-27 01750340327 B...
  • Page 47: Wall Cutout

    Planning the installation 3.1.3 3.1.3 Wall cutout 3.1.3.1 3.1.3.1 Wall cutout with 4K Safe Figure 3-27: Wall cutout with 4K Safe Without installation plinth With the 25 mm (0.99") installation plinth Copyright © 2020, Diebold Nixdorf 3-28 01750340327 B...
  • Page 48 Planning the installation 3.1.3.2 3.1.3.2 Wall cutout with 5K Safe Figure 3-28: Wall cutout with 5K Safe Without installation plinth With the 25 mm (0.99") installation plinth Copyright © 2020, Diebold Nixdorf 3-29 01750340327 B...
  • Page 49: System With Window Trim

    Figure 3-29: Installation in window trim with 4K Safe, wall thickness max. 203 mm (7.99"), without attached logo case Inside wall (system side) Outside wall (fascia side) Without installation plinth With installation plinth Copyright © 2020, Diebold Nixdorf 3-30 01750340327 B...
  • Page 50 4K Safe with a maximum wall thickness of 203 mm (7.99") with attached logo case Figure 3-30: Installation in window trim with 4K Safe, wall thickness max. 203 mm (7.99"), with attached logo case Inside wall (system side) Outside wall (fascia side) Without installation plinth With installation plinth Copyright © 2020, Diebold Nixdorf 3-31 01750340327 B...
  • Page 51 Figure 3-31: Installation in window trim with 4K Safe, wall thickness max. 306 mm (14.17"), without attached logo case Inside wall (system side) Outside wall (fascia side) Without installation plinth With installation plinth Copyright © 2020, Diebold Nixdorf 3-32 01750340327 B...
  • Page 52 4K Safe with a maximum wall thickness of 360 mm (14.17") and with attached logo case Figure 3-32: Installation in window trim with 4K Safe, wall thickness max. 360 mm (14.17"), with attached logo case Inside wall (system side) Outside wall (fascia side) Without installation plinth With installation plinth Copyright © 2020, Diebold Nixdorf 3-33 01750340327 B...
  • Page 53 Figure 3-33: Installation in window trim with 5K Safe, wall thickness max. 203 mm (7.99"), without attached logo case Inside wall (system side) Outside wall (fascia side) Without installation plinth With installation plinth Copyright © 2020, Diebold Nixdorf 3-34 01750340327 B...
  • Page 54 5K Safe with a maximum wall thickness of 203 mm (7.99") and with attached logo case Figure 3-34: Installation in window trim with 5K Safe, wall thickness max. 203 mm (7.99"), with attached logo case Inside wall (system side) Outside wall (fascia side) Without installation plinth With installation plinth Copyright © 2020, Diebold Nixdorf 3-35 01750340327 B...
  • Page 55 Figure 3-35: Installation in window trim with 5K Safe, wall thickness max. 360 mm (14.17"), without attached logo case Inside wall (system side) Outside wall (fascia side) Without installation plinth With installation plinth Copyright © 2020, Diebold Nixdorf 3-36 01750340327 B...
  • Page 56 5K Safe with a maximum wall thickness of 360 mm (14.17") and with logo area Figure 3-36: Installation in window trim with 5K Safe, wall thickness max. 360 mm (14.17"), with attached logo case Inside wall (system side) Outside wall (fascia side) Without installation plinth With installation plinth Copyright © 2020, Diebold Nixdorf 3-37 01750340327 B...
  • Page 57: Attachment Points

    These attachment points are at position (1) and the alternative at- tachment points are at position (2) (see following illustrations). Note the alignment of the installation plinth depending on the system version used. Copyright © 2020, Diebold Nixdorf 3-38 01750340327 B...
  • Page 58 Figure 3-37: Attachment points of UL safe installation plinth, max. 203 mm (7.99") wall thickness Attachment points Fascia side Installation plinth Alternative attachment points This side must always point towards the Installation plinth side with safe door Tear-off sensor attachment point Copyright © 2020, Diebold Nixdorf 3-39 01750340327 B...
  • Page 59 Figure 3-38: Attachment points of UL safe installation plinth, max. 360 mm (14.17") wall thickness Attachment points Fascia side Installation plinth Alternative attachment points This side must always point towards the Installation plinth side with safe door Tear-off sensor attachment point Copyright © 2020, Diebold Nixdorf 3-40 01750340327 B...
  • Page 60 Figure 3-39: Attachment points of CEN safe installation plinth, max. 203 mm (7.99") wall thickness Attachment points Fascia side Installation plinth Alternative attachment points This side must always point towards the Installation plinth side with safe door Tear-off sensor attachment point Copyright © 2020, Diebold Nixdorf 3-41 01750340327 B...
  • Page 61 Figure 3-40: Attachment points of CEN safe installation plinth, max. 360 mm (14.17") wall thickness Attachment points Fascia side Installation plinth Alternative attachment points This side must always point towards the Installation plinth side with safe door Tear-off sensor attachment point Copyright © 2020, Diebold Nixdorf 3-42 01750340327 B...
  • Page 62 Figure 3-41: Attachment points of UL safe installation plinth, max. 203 mm (7.99") wall thickness Installation plinth attachment points Fascia side Alternative attachment points of the instal- Side with safe door lation plinth Attachment points for tear-off sensor Copyright © 2020, Diebold Nixdorf 3-43 01750340327 B...
  • Page 63 Figure 3-42: Attachment points of UL safe installation plinth, max. 360 mm (14.17") wall thickness Installation plinth attachment points Fascia side Alternative attachment points of the instal- Side with safe door lation plinth Attachment points for tear-off sensor Copyright © 2020, Diebold Nixdorf 3-44 01750340327 B...
  • Page 64 Figure 3-43: Attachment points of CEN safe installation plinth, max. 203 mm (7.99") wall thickness Installation plinth attachment points Fascia side Alternative attachment points of the instal- Side with safe door lation plinth Attachment points for tear-off sensor Copyright © 2020, Diebold Nixdorf 3-45 01750340327 B...
  • Page 65 Figure 3-44: Attachment points of CEN safe installation plinth, max. 360 mm (14.17") wall thickness Installation plinth attachment points Fascia side Alternative attachment points of the instal- Side with safe door lation plinth Attachment points for tear-off sensor Copyright © 2020, Diebold Nixdorf 3-46 01750340327 B...
  • Page 66 UL safe with a maximum wall thickness of 203 mm (7.99") Figure 3-45: Attachment points of UL safe, max. 203 mm (7.99") wall thickness 3 Safe attachment points 4 Tear-off sensor attachment point 7 Fascia side 8 Side with safe door Copyright © 2020, Diebold Nixdorf 3-47 01750340327 B...
  • Page 67 UL safe with a maximum wall thickness of 360 mm (14.17") Figure 3-46: Attachment points of UL safe, max. 360 mm (14.17") wall thickness 3 Safe attachment points 4 Tear-off sensor attachment point 7 Fascia side 8 Side with safe door Copyright © 2020, Diebold Nixdorf 3-48 01750340327 B...
  • Page 68 CEN safe with a maximum wall thickness of 203 mm (7.99") Figure 3-47: Attachment points of CEN safe, max. wall thickness 203 mm (7.99") 3 Safe attachment points 4 Tear-off sensor attachment point 7 Fascia side 8 Side with safe door Copyright © 2020, Diebold Nixdorf 3-49 01750340327 B...
  • Page 69 CEN safe with a maximum wall thickness of 360 mm (14.17") Figure 3-48: Attachment points of CEN safe, max. wall thickness 360 mm (14.17") 3 Safe attachment points 4 Tear-off sensor attachment point 7 Fascia side 8 Side with safe door Copyright © 2020, Diebold Nixdorf 3-50 01750340327 B...
  • Page 70: Positioning Of The Installation Plinth In Relation To The Wall

    Planning the installation 3.1.6 3.1.6 Positioning of the installation plinth in relation to the wall 3.1.6.1 3.1.6.1 Positioning of the installation plinth 25 mm (0.99") from the wall Copyright © 2020, Diebold Nixdorf 3-51 01750340327 B...
  • Page 71 Alternative attachment points of the installation Side with safe door plinth Safe attachment points Attachment point of safe Tear-off sensor attachment point Cable lead-in opening Cable lead-ins into the installation plinth Wall Area for cables Copyright © 2020, Diebold Nixdorf 3-52 01750340327 B...
  • Page 72 Alternative attachment points of the installation Side with safe door plinth Safe attachment points Attachment point of safe Tear-off sensor attachment point Cable lead-in opening Cable lead-ins into the installation plinth Wall Area for cables Copyright © 2020, Diebold Nixdorf 3-53 01750340327 B...
  • Page 73 Alternative attachment points of the installation Side with safe door plinth Safe attachment points Attachment point of safe Tear-off sensor attachment point Cable lead-in opening Cable lead-ins into the installation plinth Wall Area for cables Copyright © 2020, Diebold Nixdorf 3-54 01750340327 B...
  • Page 74 Alternative attachment points of the installation Side with safe door plinth Safe attachment points Attachment point of safe Tear-off sensor attachment point Cable lead-in opening Cable lead-ins into the installation plinth Wall Area for cables Copyright © 2020, Diebold Nixdorf 3-55 01750340327 B...
  • Page 75 Alternative attachment points of the installation Side with safe door plinth Safe attachment points Attachment point of safe Tear-off sensor attachment point Cable lead-in opening Cable lead-ins into the installation plinth Wall Copyright © 2020, Diebold Nixdorf 3-56 01750340327 B...
  • Page 76 Planning the installation Area for cables Copyright © 2020, Diebold Nixdorf 3-57 01750340327 B...
  • Page 77 Alternative attachment points of the installation Side with safe door plinth Safe attachment points Attachment point of safe Tear-off sensor attachment point Cable lead-in opening Cable lead-ins into the installation plinth Wall Area for cables Copyright © 2020, Diebold Nixdorf 3-58 01750340327 B...
  • Page 78 Alternative attachment points of the installation Side with safe door plinth Safe attachment points Attachment point of safe Tear-off sensor attachment point Cable lead-in opening Cable lead-ins into the installation plinth Wall Area for cables Copyright © 2020, Diebold Nixdorf 3-59 01750340327 B...
  • Page 79 Alternative attachment points of the installation Side with safe door plinth Safe attachment points Attachment point of safe Tear-off sensor attachment point Cable lead-in opening Cable lead-ins into the installation plinth Wall Area for cables Copyright © 2020, Diebold Nixdorf 3-60 01750340327 B...
  • Page 80: Positioning Of The Safe To The Wall

    UL safe with a maximum wall thickness of 203 mm (7.99") Figure 3-57: Safe position with UL safe and wall thickness max. 203 mm (7.99") 3 Safe attachment points 8 Side with safe door 4 Tear-off sensor attachment point 11 Wall 7 Fascia side Copyright © 2020, Diebold Nixdorf 3-61 01750340327 B...
  • Page 81 UL safe with a maximum wall thickness of 360 mm (14.17") Figure 3-58: Safe position with UL safe and wall thickness max. 360 mm (14.17") 3 Safe attachment points 8 Side with safe door 4 Tear-off sensor attachment point 11 Wall 7 Fascia side Copyright © 2020, Diebold Nixdorf 3-62 01750340327 B...
  • Page 82 CEN safe with a maximum wall thickness of 203 mm (7.99") Figure 3-59: Safe position with CEN safe and wall thickness max. 203 mm (7.99") 3 Safe attachment points 8 Side with safe door 4 Tear-off sensor attachment point 11 Wall 7 Fascia side Copyright © 2020, Diebold Nixdorf 3-63 01750340327 B...
  • Page 83 With CEN safe with a maximum wall thickness of 360 mm (14.17") Figure 3-60: Safe position with CEN safe and wall thickness max. 360 mm (14.17") 3 Safe attachment points 8 Side with safe door 4 Tear-off sensor attachment point 11 Wall 7 Fascia side Copyright © 2020, Diebold Nixdorf 3-64 01750340327 B...
  • Page 84: Cable Lead-In From The Side

    Planning the installation 3.1.8 3.1.8 Cable lead-in from the side 3.1.8.1 3.1.8.1 Cable lead-in from the side for UL safe Figure 3-61: Dimensions of lateral cable lead-in in the UL safe Copyright © 2020, Diebold Nixdorf 3-65 01750340327 B...
  • Page 85 Planning the installation 3.1.8.2 3.1.8.2 Cable lead-in from the side for CEN safe Figure 3-62: Dimensions of lateral cable lead-in in the CEN safe Copyright © 2020, Diebold Nixdorf 3-66 01750340327 B...
  • Page 86: Operation And Maintenance Space

    Planning the installation 3.1.9 3.1.9 Operation and maintenance space Copyright © 2020, Diebold Nixdorf 3-67 01750340327 B...
  • Page 87 Figure 3-63: Maintenance space with UL safe, max. wall thickness 203 mm (7.99") Ventilation area * Maintenance from the left fascia side Operation and Maintenance Space ** Maintenance from the right fascia side Space required for systems with UPS Copyright © 2020, Diebold Nixdorf 3-68 01750340327 B...
  • Page 88 Figure 3-64: Maintenance space with UL safe, max. wall thickness 360 mm (14.17") Ventilation area * Maintenance from the left fascia side Operation and Maintenance Space ** Maintenance from the right fascia side Space required for systems with UPS Copyright © 2020, Diebold Nixdorf 3-69 01750340327 B...
  • Page 89 Figure 3-65: Maintenance space with CEN safe, max. wall thickness 360 mm (14.17") Ventilation area * Maintenance from the left fascia side Operation and Maintenance Space ** Maintenance from the right fascia side Space required for systems with UPS Copyright © 2020, Diebold Nixdorf 3-70 01750340327 B...
  • Page 90 Figure 3-66: Maintenance space with CEN safe, max. wall thickness 360 mm (14.17") Ventilation area * Maintenance from the left fascia side Operation and Maintenance Space ** Maintenance from the right fascia side Space required for systems with UPS Copyright © 2020, Diebold Nixdorf 3-71 01750340327 B...
  • Page 91: Ventilation Openings

    In principle, it must be ensured that the distance between the ventilation opening and the wall is at least 50 mm (1.97") (see Space required for operation and maintenance.) Figure 3-67: DN Series 250 - Ventilation openings Air outlet Copyright © 2020, Diebold Nixdorf 3-72 01750340327 B...
  • Page 92: Routing The Cables

    You must ensure that the connection cables do not impede or actually damage any moving components. NOTE For detailed information regarding the cable lead-ins, please refer to the section entitled "Dimensions of cable lead-ins". Copyright © 2020, Diebold Nixdorf 3-73 01750340327 B...
  • Page 93 L N PE Figure 3-68: Power socket Fuse or automatic circuit-breaker Connection DN Series 250 Modem connection Connection of miscellaneous equipment Copyright © 2020, Diebold Nixdorf 3-74 01750340327 B...
  • Page 94: Cable Lead-In Into The Safe From The Side

    Planning the installation 3.3.2 3.3.2 Cable lead-in into the safe from the side Figure 3-69: Lateral cable lead-in into the safe 1 Lateral cable lead-in into the safe Copyright © 2020, Diebold Nixdorf 3-75 01750340327 B...
  • Page 95: Cable Lead-In Into The Safe From Below

    Figure 3-70: DN Series 250 - Cable lead-in into the safe from below 5 Installation plinth cable lead-in 7 Fascia side 6 Floor cable lead-in 8 Side with safe door Copyright © 2020, Diebold Nixdorf 3-76 01750340327 B...
  • Page 96 (5a) and (5b) behind the safe door side (8) of the installation plinth, as in the ex- ample illustration shown here. Figure 3-71: Cable opening behind the safe door Copyright © 2020, Diebold Nixdorf 3-77 01750340327 B...
  • Page 97: Conditions For Installation

    A mounting structure that differs from the descriptions in the chapter "Installing the sys- tem" and is not compliant with regulations and must be clarified in advance with the end customer and property insurer. Copyright © 2020, Diebold Nixdorf 3-78 01750340327 B...
  • Page 98: Tear-Off Sensor

    The length of the threaded rod depends on the installation plinth used (see also chapter "In- stallation"). NOTE Power, data or alarm cables may not be routed below the recycling module or the cash media dispenser. Copyright © 2020, Diebold Nixdorf 3-79 01750340327 B...
  • Page 99: Floor Space Requirements

    3.4.4 3.4.4 Load-carrying capacity Make sure the floor space has the required load-carrying capacity. The corresponding system weight can be found in the section "Installation specifications" in the chapter "Appendix". Copyright © 2020, Diebold Nixdorf 3-80 01750340327 B...
  • Page 100: Mounting Structure

    * The overall drilling depth depends on the constructional situation. The threaded rods must be anchored at least 125 mm (4.92") in the load-bearing concrete. Excess lengths must be shortened correspondingly or, if necessary in case of deeper floor anchorages, be replaced by equivalent threaded rods. Copyright © 2020, Diebold Nixdorf 3-81 01750340327 B...
  • Page 101 Excess lengths must be shortened accordingly or, if necessary in case of deeper floor an- chorages, replaced with equivalent mounting anchors. UL thread length from the top edge of the finished floor CEN thread length from top edge of the finished floor Copyright © 2020, Diebold Nixdorf 3-82 01750340327 B...
  • Page 102: Remote Status Indicator

    Planning the installation Remote Status Indicator The optional 'Remote Status Indicator' comes with a 50 m (164.1 ft) connecting cable. The position for fastening and cable guide must be determined during planning (see Section 4.5.5). Copyright © 2020, Diebold Nixdorf 3-83 01750340327 B...
  • Page 103: Installation

    In the event of non-compliance, Diebold Nixdorf shall not assume liability for any damage that is caused to the system.
  • Page 104: Mounting Sets

    4.1.3 4.1.3 Mounting set 01750308241 (expansion anchor set) Designation Required quantity Mounting anchor (expansion anchor HST3 M20 x 170mm (6.70"), electro galva- nized, at least 700 N/mm ), washer D20 DIN 125 A Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 105: Mounting Set 01750006706 For Installation Plinth With Ul Safe

    Washer DIN 125 A17/ST, galvanized 01750186767 Caulking cartridge Upat UPM 33 Required Number Composite mortar caulking cartridge vinyl ester resin, styrene-free A caulking gun for the caulking cartridge is not included in the scope of supply. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 106: Mounting Set 01750051579 For Installation Plinth With Cen I/Iii/Iv Safe

    Washer DIN 125 A17/ST, galvanized 01750186767 Caulking cartridge Upat UPM 33 Required Number Composite mortar caulking cartridge vinyl ester resin, styrene-free A caulking gun for the caulking cartridge is not included in the scope of supply. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 107: Notes Concerning Installation

    NOTE To achieve the security level stipulated by country-specific regulations and to fulfil the re- quirements of commercial insurance companies, the system must be bolted to the load- bearing substructure of the floor. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 108: Preparing For Installation

    4.3.1 Removing transport packing Remove the packing material of the DN Series 250. Figure 4-1: Removing packaging Dispose of any packaging which is no longer required in accordance with the regulations in your country. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 109: Removing The Shipping Crate

    Always try and grasp the system as low down as possible. The system must not be shifted by exerting pressure on moving parts, such as the customer panel and the system doors. Figure 4-2: Removing the shipping crate – Contact points Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 110 Remove the shipping crate (2). Figure 4-4: Removing the shipping crate – Moving the system Dispose of the shipping crate that is no longer needed in accordance with the regulations in your country. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 111: Dismounting The Protection Plate

    Dismounting the protection plate Loosen the screw (1). Push the protection plate out of the longitudi- nal hole and remove it upwards (2). Figure 4-5: Cable routing from the side - dismounting the pro- tection plate Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 112: Mounting The Installation Plinth

    The assembly steps depicted apply for the following installation plinths: - Installation plinth 25 mm (0.99") - Installation plinth 120 mm (4.72") - Installation plinth 191 mm (7.52") NOTE The threaded rods must protrude at least 24 mm (0.94"), but no more than 25 mm (0.98"). Copyright © 2020, Diebold Nixdorf 4-10 01750340327 B...
  • Page 113 Drill the required four bore holes (1) and the bore hole for the optional tear-off sensor. Clean the holes as specified in the mounting instructions of the caulking cartridge. Figure 4-7: Drilling holes for 25 mm (0.99") installation plinth Copyright © 2020, Diebold Nixdorf 4-11 01750340327 B...
  • Page 114 (5) through the installation plinth into the floor. Rotate the nuts securely as soon as the 2K installation mortar has hardened (see manu- facturer's specifications) Figure 4-9: Countersinking the threaded rods into the bore holes Copyright © 2020, Diebold Nixdorf 4-12 01750340327 B...
  • Page 115 10. Secure the installation plinth 120 mm / 191 mm (4.72" / 7.52") with an additional Starlock fastener (3). Figure 4-10: Starlock fasteners on threaded rods for installa- tion plinth 120 mm / 191 mm (4.72" / 7.52") Copyright © 2020, Diebold Nixdorf 4-13 01750340327 B...
  • Page 116: Installing The System

    Align the system on the installation plinth. Secure the safe to the installation plinth by using four pan head screws and four wash- ers (1) (see Section 4.1). Figure 4-11: Screwing the system securely to the installation plinth Copyright © 2020, Diebold Nixdorf 4-14 01750340327 B...
  • Page 117 (3). Replace the pad for the safe and secure it in place with the two screws (4). Figure 4-13: Power and data cables – Routing the cables and inserting the pad Copyright © 2020, Diebold Nixdorf 4-15 01750340327 B...
  • Page 118 Installation Install the protection plate in the safe by following the same steps in reverse order (see Section 4.3.3). Copyright © 2020, Diebold Nixdorf 4-16 01750340327 B...
  • Page 119 If there is no fax machine available, the form will need to be faxed to this number at a later point in time. NOTE The Confirmation of Installation is for submission to the insurance company by the operat- ing company. Copyright © 2020, Diebold Nixdorf 4-17 01750340327 B...
  • Page 120: Without Installation Plinth

    (2). Figure 4-14: Installation without installation frame - Marking out bore holes NOTE Do not drill through the safe Do not drill through the floor mounting holes of the safe. Copyright © 2020, Diebold Nixdorf 4-18 01750340327 B...
  • Page 121 Drill 1 hole (2) for the tear-off sensor. Figure 4-15: Installation without installation frame - Drilling holes Align the system over the bore holes (1). Insert the cable clamps. Figure 4-16: Aligning installation with the installation plinth system Copyright © 2020, Diebold Nixdorf 4-19 01750340327 B...
  • Page 122 Seal around the bottom edges of the safe with silicone (1). For this, use a silicone that has the same color as the safe itself. Figure 4-18: Sealing the bottom edges of the safe Copyright © 2020, Diebold Nixdorf 4-20 01750340327 B...
  • Page 123 Remove the filling element from the safe (2). Figure 4-19: Laying cables from the side - Remove filler Lay the power and data lines from the side into the system (1). Figure 4-20: Laying cables from the side - Laying cables Copyright © 2020, Diebold Nixdorf 4-21 01750340327 B...
  • Page 124 Installation Then re-install the protection plate by following the same steps in reverse order (see Section 4.3.3). Copyright © 2020, Diebold Nixdorf 4-22 01750340327 B...
  • Page 125: Installing Window Trims

    Screw the 4 adapter plates to the side piece of the frame (1). Note the correct installation position of the adapter plates (see illustration). Figure 4-22: Securing the adapter plate to the side piece of the frame Copyright © 2020, Diebold Nixdorf 4-23 01750340327 B...
  • Page 126 Figure 4-23: Securing the top part of the frame Secure the bottom part of the frame to the side piece of the frame with 2 screws per side (1). Figure 4-24: Securing the bottom part of the frame Copyright © 2020, Diebold Nixdorf 4-24 01750340327 B...
  • Page 127 Figure 4-25: Tightening the top sealing frame 10. Position the sealing frame from below to the fastening points of the tunnel. 11. Tighten the sealing frame from above (2). Figure 4-26: Tightening the bottom sealing frame Copyright © 2020, Diebold Nixdorf 4-25 01750340327 B...
  • Page 128 14. Place the left side piece of the sealing frame onto the inside of the tunnel (1). 15. Secure the left side piece with 3 spacers (2). Figure 4-28: Securing the left side piece of the sealing frame Copyright © 2020, Diebold Nixdorf 4-26 01750340327 B...
  • Page 129 Figure 4-29: Tightening the side pieces of the sealing frame 17. Seal the lateral and the top edge of the seal- ing frame using silicone (not included in the delivery package). Figure 4-30: Sealing lateral edges with silicone Copyright © 2020, Diebold Nixdorf 4-27 01750340327 B...
  • Page 130 18. Hang the two adjusting plates on the right and left sides of the fascia (1). Figure 4-31: Securing the adjusting plates 19. Attach each adjusting plate with one screw per side (1). Figure 4-32: Fastening the adjusting plates in place Copyright © 2020, Diebold Nixdorf 4-28 01750340327 B...
  • Page 131 Figure 4-33: Sliding in the fascia and securing the adjusting bolt 23. Pull out the fascia (1). 24. Hang the window trim on the fascia (2). Figure 4-34: Placing the front frame on the fascia Copyright © 2020, Diebold Nixdorf 4-29 01750340327 B...
  • Page 132 25. Screw the window trim from the back side using 4 screws (1). Figure 4-35: Screwing down the window trim 26. Secure each adjusting bolt from the back side with a nut (1). Figure 4-36: Securing the adjusting bolts with nuts Copyright © 2020, Diebold Nixdorf 4-30 01750340327 B...
  • Page 133 27. Connect the connection for the fascia lighting Figure 4-37: Connecting the logo illumination 28. Slide the fascia in and check whether the fascia is justified with the sections of trim. Adjust the sec- tions of trim if necessary. Copyright © 2020, Diebold Nixdorf 4-31 01750340327 B...
  • Page 134: Mounting The Customer Connection Box

    Position Part Number First customer connection box Bottom 01750083012 Second customer connection box Top 01750252111 The customer connection boxes are supplied pre- assembled on the mounting fixture. Figure 4-38: Customer connection box pre-assembled Copyright © 2020, Diebold Nixdorf 4-32 01750340327 B...
  • Page 135 Secure the bottom customer connection box with two previously removed screws (1). Secure the top customer connection box with two previously removed screws (1). Figure 4-40: Mounting the customer connection box – Tight- ening the customer connection box Copyright © 2020, Diebold Nixdorf 4-33 01750340327 B...
  • Page 136: Table 4-1 Example Assignment Of Usb Cables To The Customer Connection Box

    Connect the lower-ranked USB cable (e.g. 'U') to the first customer connection box. Connect the higher-ranked USB cable (e.g. 'V') to the second customer connection box. Connect the optional 24V voltage cable to the first customer connection box. Copyright © 2020, Diebold Nixdorf 4-34 01750340327 B...
  • Page 137: Installing The Remote Status Indicator

    Fixings Ø 4 mm (0.16") NOTE The enclosed mounting material is used to secure the indicator to masonry or wooden paneling. 4.5.5.1.2 4.5.5.1.2 Installation Remove the remote status indicator - standard from the packaging. Copyright © 2020, Diebold Nixdorf 4-35 01750340327 B...
  • Page 138 Drill the required bore holes: Drilling depth: 20 mm (0.79"), hole diameter: 4 mm (0.16") and insert the supplied fixtures into the holes. Use the supplied screws to secure the bot- tom part to the wall. Press the front cover onto the bottom part. Copyright © 2020, Diebold Nixdorf 4-36 01750340327 B...
  • Page 139 (White – 12 yellow light) GREEN - 13 GREEN LIGHT (Green – 13 green light) BLACK - 14 GND (Black – 14 ground) Connect the individual wires to the customer connection box as follows: Copyright © 2020, Diebold Nixdorf 4-37 01750340327 B...
  • Page 140 Figure 4-42: Remote Status Indicator – Connection to a customer connection box Contact Designation Wire 'RED – 11 RED LIGHT' Wire 'WHITE – 12 YELLOW LIGHT' Wire 'GREEN – 13 GREEN LIGHT' Wire 'BLACK – 14 GND' Close the system. Copyright © 2020, Diebold Nixdorf 4-38 01750340327 B...
  • Page 141 Dimensions (W x H x D): 118 mm x 96.5 mm x 40.5 mm (4.65" x 3.8" x 1.59") Phillips screws SPAX 4 x 40 (half-round screws) Fixings Ø 6 mm (0.24") NOTE The enclosed mounting material is used to secure the indicator to masonry or wooden paneling. Copyright © 2020, Diebold Nixdorf 4-39 01750340327 B...
  • Page 142 Only applicable for masonry: Drill the required bore holes: Drilling depth: 40 mm (1.57"), hole diameter: 6 mm (0.24") and insert the supplied fixtures into the holes. Copyright © 2020, Diebold Nixdorf 4-40 01750340327 B...
  • Page 143 Remove the required label (1). Apply it to the adhesive surface (2) of the 'Remote Status Indicator' - Audio. Run the connection cable from the 'Remote Status Indicator' - Audio to the corresponding system. Copyright © 2020, Diebold Nixdorf 4-41 01750340327 B...
  • Page 144 Run the connection cable in the system in such a way that it cannot be damaged when pulling out any components. Shorten the connecting cable if so required to the appropriate length (see section "Shortening the cable ends"). Copyright © 2020, Diebold Nixdorf 4-42 01750340327 B...
  • Page 145 Figure 4-43: Remote Status Indicator Audio – Connection to a customer connection box Contact Designation Wire 'RED – 11 RED LIGHT' Wire 'WHITE – 12 YELLOW LIGHT' Wire 'GREEN – 13 GREEN LIGHT' Wire 'BLACK – 14 GND' Close the system. Copyright © 2020, Diebold Nixdorf 4-43 01750340327 B...
  • Page 146 Use a screwdriver to press carefully through openings (1) and (2) until the tabs behind them disengage. Remove the front cover (3) forwards. Release the four terminals of the terminal strip (1) and remove the front cover. Copyright © 2020, Diebold Nixdorf 4-44 01750340327 B...
  • Page 147 4.5 mm (0.18") of the individual wire insulation. The individual wire ends must be twisted. Lead the connecting cable through the opening in the lower section and secure it with the strain re- lief. Copyright © 2020, Diebold Nixdorf 4-45 01750340327 B...
  • Page 148 Wire 'WHITE – YELLOW LIGHT' Wire 'GREEN – GREEN LIGHT' Wire 'BLACK – GND' 11. Press the front cover onto the bottom part. Ensure that no wires are damaged in the process. Copyright © 2020, Diebold Nixdorf 4-46 01750340327 B...
  • Page 149 (2) to one side. Release the four terminals of the terminal strip and disconnect the cable from the ter- minal strip (1). Remove the connecting cable with the spacer from cable guide (2). Copyright © 2020, Diebold Nixdorf 4-47 01750340327 B...
  • Page 150 Shorten the cable end as shown in the following illustration. 10. You must strip approx. 25 mm (0.98") of the cable insulation and 4.5 mm (0.18") of the in- dividual wire insulation. The individual wire ends must be twisted. Copyright © 2020, Diebold Nixdorf 4-48 01750340327 B...
  • Page 151 Wire 'GREEN – GREEN LIGHT' Wire 'BLACK – GND' 12. Press the connecting cable with the spacer into the cable guide (2). 13. Mount the board and the back panel as described above in the disassembly. Copyright © 2020, Diebold Nixdorf 4-49 01750340327 B...
  • Page 152: Replacement Installation

    - CS 2550 - ProCash 2050 Description Part number Quantity Front cover with attached logo case 01750336541 Plate arms, painted 01750336491 Round head screws M4x8 9550408521 Sealing tape 01750344049 Cover plate 01750343954 Copyright © 2020, Diebold Nixdorf 4-50 01750340327 B...
  • Page 153 Part number Quantity Front cover without attached logo case 01750336515 Plate arms 01750336491 Round head screws M4x8 9550408521 Sealing tape 01750344049 Cover plate II 01750343956 L holder 01750336451 Plate arms (painted) 01750336491 Copyright © 2020, Diebold Nixdorf 4-51 01750340327 B...
  • Page 154 Part number Quantity Front cover without attached logo case 01750336515 Plate arms 01750336491 Round head screws M4x8 9550408521 Sealing tape 01750344049 Cover plate II 01750343956 L holder 01750336451 Plate arms (painted) 01750336491 Copyright © 2020, Diebold Nixdorf 4-52 01750340327 B...
  • Page 155: Dimensions For The Replacement Installation

    Installation 4.6.2 4.6.2 Dimensions for the replacement installation 472 (18.58") 15 (0.59") 776 (30.55") 420 (16.53") Figure 4-46: Dimensions for replacement installation * Without logo area ** With logo area Copyright © 2020, Diebold Nixdorf 4-53 01750340327 B...
  • Page 156: Replacing The System

    15 mm (0.59") due to the additional front cover. Observe the following dimensioned drawings in this connection. Figure 4-47: Dimensions to the wall with replacement installation, max. wall thickness 188 mm (7.40") 1 Installation plinth Wall Copyright © 2020, Diebold Nixdorf 4-54 01750340327 B...
  • Page 157 Installation 7 Wall cutout Copyright © 2020, Diebold Nixdorf 4-55 01750340327 B...
  • Page 158 15 mm (0.59") due to the additional front cover. Observe the following dimensioned drawings in this connection. Figure 4-48: Dimensions to the wall with replacement installation, max. wall thickness 345 mm 1 Installation plinth Wall 7 Wall cutout Copyright © 2020, Diebold Nixdorf 4-56 01750340327 B...
  • Page 159 Mounting set CS 2550 / CS4560 / ProCash 2050 Secure the four plate arms (1) to the front cover with 2 screws each. Figure 4-50: Screwing the replacement installation CS / Pro- Cash - arms to the cover Copyright © 2020, Diebold Nixdorf 4-57 01750340327 B...
  • Page 160 Apply the sealing tape in speedy fashion The volume of the sealing tape becomes greater within a short time. Apply it in speedy fashion and mount it immediately afterwards on the wall cutout. Copyright © 2020, Diebold Nixdorf 4-58 01750340327 B...
  • Page 161 ü At least two persons are required to lift the front cover. Lift the front cover by the fascia and bring it up to the wall cutout. Figure 4-54: Securing the front cover at the wall cutout Copyright © 2020, Diebold Nixdorf 4-59 01750340327 B...
  • Page 162 Figure 4-55: Securing the upper side of the sealing frame 11. Position the sealing frame from below to the fastening points of the tunnel. 12. Tighten the sealing frame hand-tight from above (2). Figure 4-56: Securing the underside of the sealing frame Copyright © 2020, Diebold Nixdorf 4-60 01750340327 B...
  • Page 163 (2). Figure 4-57: Securing the sealing frame 15. Place the right side piece of the sealing frame onto the inside right of the tunnel (1). Figure 4-58: Position the side piece on the right Copyright © 2020, Diebold Nixdorf 4-61 01750340327 B...
  • Page 164 16. Secure the right side piece with the 3 spac- ers (1). Figure 4-59: Securing the spacer on the right 17. Secure the right side piece with 3 screws (1). Figure 4-60: Screwing the side piece on the right in place Copyright © 2020, Diebold Nixdorf 4-62 01750340327 B...
  • Page 165 (1). Figure 4-61: Position the side piece on the right 19. Secure the left side piece with three 3 spac- ers (1). Figure 4-62: Securing the spacer on the right Copyright © 2020, Diebold Nixdorf 4-63 01750340327 B...
  • Page 166 20. Secure the left side piece with 3 screws (1). Figure 4-63: Screwing the side piece on the left in place 21. Secure the side pieces with a total of 4 nuts (1). Figure 4-64: Securing side pieces with nuts Copyright © 2020, Diebold Nixdorf 4-64 01750340327 B...
  • Page 167 Figure 4-65: Screwing the cover plates to the system Mounting set CS 2550 / CS4560 / ProCash 2050 23. Drill four holes into the rear of the wall for each cover plate. Figure 4-66: Drilling holes into the wall Copyright © 2020, Diebold Nixdorf 4-65 01750340327 B...
  • Page 168 25. Mount the top cover plate (1) with a total of 4 screws. 26. Mount the two lower mounting plates (2) and (3) to the plate arms with two screws each. Figure 4-68: Secure the rear of Mounting set DS5550 / Opteva 562 Copyright © 2020, Diebold Nixdorf 4-66 01750340327 B...
  • Page 169 28. Drill two bore holes each (4) - (7) for the lower mounting plates. 29. Secure the plates with a total of 7 screws (1) – (7). Figure 4-69: Drilling and securing the rear of Mounting set DS5550 / Opteva 562 Copyright © 2020, Diebold Nixdorf 4-67 01750340327 B...
  • Page 170: Putting Into Service

    Never start up the system without a pad and additional plates in place. NOTE Connection of main and data cables Only qualified personnel are allowed to connect the mains and data cables. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 171: Appendix

    After checking off all items, copy this list, send it to your head of operations and make arrange- ments for an installation date. Name: Telephone number: Fax number: Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 172 Are there cavities in the installation area (cable duct, raised floor)? Are the operation and maintenance spaces sufficient? Is the equipment screened from external light (sunlight)? Is a video surveillance system to be installed? Is a door opener system to be installed? Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 173 Is the generation prepared on the host processor? Has the MM module or CIM06 been ordered and is it available? Have the EDM or EPP keys been prepared? Is the paper and money ready for initial start-up? Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 174 Have you discussed the diameter of the hole that is to be drilled and the fixing to be used for the tear-off sensor with the local alarm technician? Hole diameter? _________________ Fixing to be used? _________________ Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 175 Are there mats or grates at the entrance? Flooring materials on the transport route (please check off) Screed/rough concrete Carpet Raised floor Marble floor Tiles Other Checked by customer: Checked by installation technician: Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 176 Appendix Notes concerning installation preparation Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 177: Technical Data

    Fuse *the rated current consumption depends on the configuration Heating 1 100 - 120 V 220 – 240 V (without system) 4.5 A 2.5 A Rated current consumption: 400 W 400 W Active power: Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 178 10 A slow-blow fuse 10 A slow-blow fuse Heating 1 16 A automatic circuit breaker 16 A automatic circuit breaker Degree of protection according to EN 60529 IP 54 IP 54 Outer area IP 20 IP 20 Interior Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 179 14.87 kN/m² CEN IV EXGas safe: System weight*: 656 kg (1446.23 lb) 686 kg (1512.37 lb) Surface load: 14.87 kN/m² 15.01 kN/m² * Weight specifications refer to the empty weight of the system. Copyright © 2020, Diebold Nixdorf 01750340327 B...
  • Page 180: Environmental Conditions

    (e.g. sound insulating walls, etc.). These must comply with the environmental conditions that apply to the specific system (see above) and the maintenance spaces (see chapter "Planning the installation", section "Required Operation and Maintenance Spaces"). Copyright © 2020, Diebold Nixdorf 6-10 01750340327 B...
  • Page 181: Compliance With Standards And Approvals

    If this is the case, then the operator may be required to implement suitable remedial measures All other devices connected to this product must comply with the EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU. Copyright © 2020, Diebold Nixdorf 6-11 01750340327 B...
  • Page 182 Certification for data transmission The certification number or CE mark of the data transmission module (if available) is attached directly to the DT card or to the housing of the system unit. Copyright © 2020, Diebold Nixdorf 6-12 01750340327 B...
  • Page 183: Environmental Protection

    Used batteries can be disposed of free of charge throughout the EU. Labels on plastic parts of the housing Please do not stick any labels on plastic parts of the housing since that would make recycling more diffi- cult. Copyright © 2020, Diebold Nixdorf 6-13 01750340327 B...