Name/Value
44.18
Brake fault delay
0.00 ... 60.00 s
45

45 Energy efficiency

45.01
Saved GW hours
0...65535 GWh
45.02
Saved MW hours
0...999 MWh
45.03
Saved kW hours
0.0 ... 999.9 kWh
45.05
Saved money
x1000
0...4294967295
thousands
45.06
Saved money
0.00 ... 999.99 units Monetary savings.
Description
Defines a close fault delay, ie. time between brake closure
and brake close fault trip.
Brake close fault delay.
Settings of the energy savings calculator.
See also section
Energy savings calculator
Energy saved in GWh compared to direct-on-line motor
connection. This parameter is incremented when
Saved MW hours
rolls over.
This parameter is read-only (see parameter
calculations
reset).
Energy savings in GWh.
Energy saved in MWh compared to direct-on-line motor
connection. This parameter is incremented when
Saved kW hours
rolls over.
When this parameter rolls over, parameter
hours
is incremented.
This parameter is read-only (see parameter
calculations
reset).
Energy savings in MWh.
Energy saved in kWh compared to direct-on-line motor
connection.
If the internal braking chopper of the drive is enabled, all
energy fed by the motor to the drive is assumed to be
converted into heat.
When this parameter rolls over, parameter
hours
is incremented.
This parameter is read-only (see parameter
calculations
reset).
Energy savings in kWh.
Monetary savings in thousands compared to direct-on-line
motor connection. This parameter is incremented when
Saved money
rolls over.
The currency is defined by parameter
unit.
This parameter is read-only (see parameter
calculations
reset).
Monetary savings in thousands of units.
Monetary savings compared to direct-on-line motor
connection. This value is a calculated by multiplying the
saved energy in kWh by the currently active energy tariff
(45.14 Tariff
selection).
When this parameter rolls over, parameter
money x1000
is incremented.
The currency is defined by parameter
unit.
This parameter is read-only (see parameter
calculations
reset).
Parameters 187
(page 54).
45.02
45.21 Energy
45.03
45.01 Saved GW
45.21 Energy
45.02 Saved MW
45.21 Energy
45.06
45.17 Tariff currency
45.21 Energy
45.05 Saved
45.17 Tariff currency
45.21 Energy
Def/FbEq16
0.00 s
100 = 1 s
-
1 = 1 GWh
-
1 = 1 MWh
-
10 = 1 kWh
-
1 = 1
thousand
-
1 = 1 unit