Chapter 1
Digital Module Operation in a Control System
Controller and Software
Compatibility
Standard Modules
DC INPUT
DC INPUT
DC OUTPUT
ANALOG INPUT
5069-IB16
5069-IB16
5069-IY4
5069-OB16
DC INPUT
DC INPUT
DC OUTPUT
5069-IB16
5069-IB16
5069-OB16
UPS
R
R
OK
FAN 1
B
B
RUN
SD
F
FORCE
FAN 2
F
MP
NET B1
LINK B1
NET A1
LINK A1
SA
NET A2
SPEED X1
LINK A2
LINK X1
CompactLogix 5480
Safety Modules
OUTPUT
SIL2 CPU
5069-IB8S
5069-IB8S
5069-L3100ERMS2
5069-OBV8S
Compact GuardLogix
18
Controller and programming software compatibility requirements apply when
you use Compact 5000 I/O digital modules. A module type and how it is used
affect which requirements apply.
You must also consider Logix Designer application version requirements when
you design your system. For example, you can use safety modules only with the
ANALOG OUTPUT
Logix Designer application, version 32 or greater.
5069-OF8

Controller Compatibility

Compatibility between Logix 5000 controllers and Compact 5000 I/O digital
modules varies based on module type and location. That is, whether the
ANALOG INPUT
ANALOG OUTPUT
5069-IY4
5069-OF8
module is standard or safety and whether it is local or remote.
For example, CompactLogix™ 5380 and CompactLogix 5480 controllers are
compatible with local or remote Compact 5000 I/O standard modules.
Compact GuardLogix® 5380 controllers are compatible with local or remote
Compact 5000 I/O digital modules.

Software Compatibility

OUTPUT
5069-OBV8S
Compact 5000 I/O digital modules are supported in different minimum
versions of the Logix Designer application.
For example, Compact 5000 I/O standard modules support the Logix
Designer application, version 28 or later. Compact 5000 I/O safety modules
support the Logix Designer application, version 32 or later.
IMPORTANT Logix 5000 controllers support different minimum versions of Logix Designer
Rockwell Automation Publication 5069-UM004A-EN-P - April 2019
application. You must consider the different device requirements when you
design your system.
For example, to use a 5069-IB16 input module with a 5069-L330ERM
controller, you can use the Logix Designer application, version 29 or later.
However, to use a 5069-IB16 input module with a 5069-L350ERM controller,
you can use the Logix Designer application, version 30 or later.
For more information on compatibility requirements, see
Table 3 on page 19