Emerson FB2200 Instruction Manual page 92

Flow computer
Hide thumbs Also See for FB2200:
Table of Contents

Advertisement

Emerson FB2200 Flow Computer Instruction Manual
D301784X012
March 2019
Symbol(s) representing the status of a value may appear in the upper right of the display, next to
the description. Multiple symbols may be shown. If there are no data quality issues, no symbols will
be shown.
Table 4-2. Symbols on Display
Symbol
88
Option
Usage
LEFT button
Idle Mode (Screen is off)
Hold to Wake up the display.
Screen Saver Mode
Log out (if logged in)
Data Entry Mode
Tap once to move the cursor LEFT. Hold to perform action shown
on screen, for example "Hold to Accept".
RIGHT button
Data Entry Mode
Tap once to move the cursor RIGHT. Hold to perform action shown
on screen, for example "Hold to Cancel".
Explanation
Alarm - The parameter value shown is in an alarm state (High Alarm, Low Alarm,
etc.)
Override - The parameter value shown is in override mode (i.e. a user entered
fixed value)
Fault - The parameter value shown is somehow invalid
Unverified - For parameter values that require additional validation (beyond
simple database min/max range checking, the parameter value shown has not
yet been validated by the firmware).