Maintenance
9.4
Leak Test
9.5
Safety procedures
It is the contractor's responsibility to ensure that the device is checked by an expert in periods of
·
max. 1 year and all recognized errors are removed (à see BGR 500).
The corresponding legal regulations and the regulations of the declaration of conformity have to be
·
observed!
We recommend that after checking the device, the badge "Safety checked" is put on the device.
·
(Order-No.: 2904.0056+inspection sticker with date).
You can receive these badges from us.
The check by an expert must be proved!
Device
Year
5270.0011/5270.0012/5270.0013/5270.0014
Check the device for leaks at least every three months.
Apply the suction pad to a flat air-tight surface.
Switch the vacuum blower on and wait until a vacuum of at least -200 mbar
is reached.
If this vacuum level is not reached, check:
whether the seals or hoses are damaged,
that the connectors are tight,
that the filter element is clean.
Date
V3
Expert
24 / 25
Company
GB