Installation
2
6.6
Mounting of the suction plate with counterholder
3
5270.0011/5270.0012/5270.0013/5270.0014
Press the closing brackets (2) downwards - the clamping bracket
is released from the counterholder.
Repeat steps 1 and 2 on the other side of the device. The suction
plate is now detached.
Remove the suction plate.
Place the device on the suction plate in the center.
Hook the U-bolt of the closing bracket (2) into the
counterholder (3).
Pull up the closing bracket (2).
Fold down the safety clip (1).
Repeat this procedure on the other side of the device - (suction
plate is now mounted on the device).
2
V3
18 / 25
GB