Extron electronics EBP 108 RAAP Button Panel Setup Manual page 8

Table of Contents

Advertisement

EBP 108 RAAP Button Panel • Setup Guide (Continued)
EBPs that are relatively far from the control processor (see the eBUS Technology Reference Guide at
details) can be connected to an optional Extron PS 1220EB eBUS power inserter (see figure 7), or an Extron 12 VDC desktop
power supply (see figure 8).
COM 1
COM 2
Tx Rx
G
RTS CTS
Tx Rx
POWER
VOL
RELAYS
12V
1.0A MAX
V
C G
1
2
IPCP Pro
EBP 108 RAAP
Cabling an eBUS System with an PS 1220EB Power Supply and Distribution Hub
Figure 7.
EBP 108 RAAP
EBP 108 RAAP
EBP 108 RAAP
BUS ID
ON
1
2 3 4 5 6
Cabling EBP Panels with an Extron Power Supply
Figure 8.
8
DIGITAL I/O
IPCP PRO 250
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
G
1
2
3
4
G
e B U S
I R/ S
C
+V +S
-S
G
LAN
PWR OUT = 6W
S G
X
ATTENTION:
ATTENTION:
Do NOT connect the power
Do NOT connect the power
pin to any device that is already powered
pin to any device that is already powered
by the IPCP Pro control processor or by
by the IPCP Pro control processor or by
an additional power supply.
an additional power supply.
+ Signal
- Signal
Ground
COM 1
COM 2
DIGITAL I/O
Tx Rx
G
RTS CTS
Tx Rx
G
1
2
3
4
POWER
VOL
RELAYS
e BUS
12V
1.0A MAX
V
C G
1
2
C
+V +S
-S
G
PWR OUT = 6W
IPCP Pro
POWER LOAD = 0.5 W
STATUS
eBUS DISTRIBUTION HUB
+V +S -S G
+V +S -S G
+V +S -S G
+V +S -S G
LINK
COM ERROR
ID ERROR
eBUS Connections
• Connect up to ve eBUS
endpoint devices to the PS 1220EB.
• Wire the connectors the same at
both ends.
• All ports are identical and
interchangeable.
PS 1220EB
100-240V
50-60Hz
0.6A MAX
+V +S
-S
G
+V +S
-S
G
eBUS 24 WATTS MAX
+V +S
-S
G
+V +S
-S
G
Power Input
Power Input
X
(100-240 VAC,
(100-240 VAC,
50-60 Hz)
50-60 Hz)
Tie drain wires
to ground.
EBP 108 RAAP
BUS ID
ON
1
2 3 4 5 6
EBP 108 RAAP
BUS ID
ON
1
2 3 4 5 6
IPCP PRO 250
3/16" (5 mm) Max.
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
G
IR/S
LAN
S
G
X
Tie drain wires to ground.
RESET
External Power Supply
(12 VDC, 1.5 A max.)
EBP 108 RAAP
NOTE:
supply before connecting it to the EBP.
www.extron.com
+V +S
-S
G
+V +S
-S
G
+12 VDC
+ Signal
- Signal
Ground
POWER LOAD = 0.5 W
STATUS
eBUS DISTRIBUTION HUB
+V +S -S G
+V +S -S G
+V +S -S G
+V +S -S G
LINK
COM ERROR
RESET
ID ERROR
POWER LOAD = 0.5 W
STATUS
eBUS DISTRIBUTION HUB
LINK
+V +S -S G
+V +S -S G
+V +S -S G
+V +S -S G
COM ERROR
RESET
ID ERROR
X
Ground
- Signal
- Signal
+ Signal
+ Signal
Ground
- Signal
- Signal
+ Signal
+ Signal
+12 VDC
+12 VDC
Smooth
Ridged
+12 VDC input
– Return
Ground
all Devices
Check the polarity of the power
for
3/16"
(5 mm)
Max.

Advertisement