Regency Excalibur P90E Zero Owners & Installation Manual page 34

Clearance direct vent gas fireplace
Table of Contents

Advertisement

installation
Vertical Venting with Two (2) 90
Must Use: 5" x 8" Simpson Direct Vent Piping with FPI Increaser
Starter Collar (Part #946-605), unless V1 is greater than or equal
to 4'-6" then use 4" x 6-5/8" piping.
One 90
Option V
A)
0' Min.
B)
1' Min.
C)
2' Min.
D)
3' Min.
E)
4' Min.
F)
5' Min.
For additional vertical venting with 2 x 90
"Rigid Pipe Venting Arrangements - Horizontal Termination"
section.
Vertical Venting with Three (3) 90
Must Use: 5" x 8" Simpson Direct Vent Piping with FPI Increaser
Starter Collar (Part #946-605..
One 90
Option
V
A)
6" Min. 2' Max. 3' Min.
B)
1' Min.
C)
2' Min.
D)
3' Min.
E)
4' Min.
F)
5' Min.
G)
6' Min.
H)
7' Min.
|
34
Regency Excalibur
Elbows
o
elbow = Two 45
elbows.
o
o
H
V + V1
With these options, max. total
pipe length is 30 feet with min.
2' Max. 1' Min.
of 6 feet total vertical and max.
4' Max. 2' Min.
8 feet total horizontal.
5' Max. 3' Min.
6' Max. 4' Min.
Please note min. 1 foot
between 90
7' Max. 5' Min.
required.
8' Max. 6' Min.
o
elbows, refer to the
Elbows
o
elbow = Two 45
elbows.
o
o
H + H1 V + V1
With these options, max.
total pipe length is 30 feet
2' Max. 3' Min.
with min. of 10 feet total
3' Max. 4' Min.
vertical and max. 8 feet total
4' Max. 6' Min.
horizontal.
5' Max. 7' Min.
Please note min. 1 foot
6' Max. 8' Min.
between 90
7' Max.
9' Min.
required.
8' Max. 10' Min.
P90E-11 Direct Vent Gas Stove
®
elbows is
o
elbows is
o