WARNING:
If the information in these instructions are not followed exactly, a fi re or
explosion may result causing property damage, personal injury or loss
of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and liquids in the
vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed installer, service
agency or the gas supplier.
Tested by:
918-522b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
P36D-1 Zero Clearance
Direct Vent Gas Fireplace
MODELS:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
P36D-NG1 Natural Gas
Owners & Installation Manual
FOR YOUR SAFETY
What to do if you smell gas:
 Do not try to light any appliance
 Do not touch any electrical switch: do not
use any phone in your building.
 Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
 If you cannot reach your gas supplier, call
the fi re department.
P36D-LP1 Propane
05/04/11

Advertisement

Table of Contents
loading

Summary of Contents for Regency P36D-NG1

  • Page 1 P36D-1 Zero Clearance Direct Vent Gas Fireplace MODELS: P36D-NG1 Natural Gas P36D-LP1 Propane Owners & Installation Manual WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, a fi re or What to do if you smell gas: explosion may result causing property damage, personal injury or loss ...
  • Page 2 To the New Owner: Congratulations! ® You are the owner of a state-of-the-art Gas Fireplace by REGENCY FIREPLACE PROD- UCTS The P36D-1 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P36D-1 has been approved by Warnock Hersey for both safety and effi...
  • Page 3 INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This REGENCY ® product has been tested and listed by Warnock Hersey to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88a-2007/ CSA 2.33a-2007 and GAS-FIRED APPLIANCES FOR USE AT HIGH ATLITUDES CAN/CGA 2.17-M91.
  • Page 4: Table Of Contents

    Unit installation with Vertical Termination ....34 Before You Start ............9 Direct Vent System (Flex) Important Message .............10 Installation Procedures ..........35 General Safety Information..........10 P36D-NG1 System Data ..........36 Installation Checklist ...........10 P36D-LP1 System Data ..........36 Locating Your High Elevation .............36 Gas Fireplace .............. 11 Gas Line Installation ............36...
  • Page 5 TABLE OF CONTENTS OPERATING INSTRUCTIONS PARTS LIST Main Assembly ............63 Operating Instructions ..........50 Burner Assembly & Log Set.........64 ® Shutdown Procedure ...........50 Regency Bay Front Assembly ........65 ® Regency Flush Front Assembly .........66 First Fire ..............50 ® Hampton Cast Lighting Procedure ............50 Faceplate &...
  • Page 6: Safety Label

    CGA-2-17-M91, ANSI Z21.88a-2007 / CSA 2.33a-2007 WN# 16462 MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE. Minimum Clearances to Combustibles / NATURAL GAS: Model P36D-NG1 APPAREIL FONCTIONNANT AU NATURAL GAZ Degagement Minimum De Materiaux Combustibles CONCU POUR ETRE POELE: Modéle P36D-NG1 Ceiling 0"...
  • Page 7: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 8: Unit Dimensions

    INSTALLATION UNIT DIMENSIONS 33"(838mm) 36" (914mm) 36"(914mm) 17-1/8"(435mm) HAMPTON FACEPLATE DIMENSIONS 43-1/4” (1099mm) 1-1/4” (32mm) 32-1/4” (819mm) ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 9: Before You Start

    SERIOUS HOUSE FIRE. CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 10: Important Message

    1) Locate appliance 14) Under no circumstances should any solid fuels a) Room location (Refer to "Locating Your Gas The P36D-NG1 or P36D-LP1 Direct Vent Fireplace (wood, paper, cardboard, coal, etc.) be used in fi replace" section) must be installed in accordance with these this appliance.
  • Page 11: Locating Your Gas Fireplace

    fi replace to the outside of the building, allowing the fi replace to be operated with less heat entering the room. The kit may be used on either the left or right side. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 12: Clearances

    Bay or Flush Front 6"* (152mm) Hampton Cast Faceplate 6"* (152mm) Full Screen Doors 6"* (152mm) ® * Measured from Surround or Front. See Regency Clearances section for dimensions. Horizontal Vent Clearances: 2" (51mm) Side 1-1/2" (38mm) Bottom 1-1/2" (38mm) Vertical Vent Clearances 1-1/4"...
  • Page 13: Regency ® Clearances

    INSTALLATION ® REGENCY CLEARANCES Clearances for Bay Front, Flush Front & Full Screen Doors ® HAMPTON CLEARANCES TRIPOLI ARCH DOOR CLEARANCES ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 14: Regency Combustible Mantel Clearances

    INSTALLATION REGENCY ® COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in Diagrams 1 & 2. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 15 INSTALLATION REGENCY ® SERIES COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 16: Hampton ® Combustible Mantel Clearances

    Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 17: Regency ® Mantel Leg Clearances

    INSTALLATION ® REGENCY MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: Maximum 1-1/2" projection at 2" minimum clearance. HAMPTON ® TRIM MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: P36D Fireplace Hampton ® Cast Faceplate Width: 43-1/4"...
  • Page 18: Framing And Finishing

    2) Frame in the enclosure for the unit with framing material. The framed opening is 37-1/4" high x 36-1/4" wide x 17-3/8" deep (946mm high x 921mm wide x 441mm deep). ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 19: Tripoli Arch Door Framing Note

    For complete framing dimensions - see page 57 in this manual. diagram 2. The Tripoli Arch Door also requires steel stud framing above and on each side of the unit, see diagram 2. Diagram 2 ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 20: Unit Assembly Prior To Installation

    Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 21: Exterior Vent Termination Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 22: Venting

    3) If you are installing the P36 into a FPI Cabinet Mantel Kit, use the minimum horizontal vent height (centre-line of 40-1/2"). Remember to include the mantel base (3" in height) in your calculations and to maintain the 2" clearance to the underside of the mantel top. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 23: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    46DVA-ES (N/A - FPI) 4DT-OS SV4SU Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM TE-4DE90 Wall Thimble Support/Ceiling Support 46DVA-DC SV4PF TE-4DE90B Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF Trim Plate-Black 4DT-TP 4DFPB 4DCP SV4LA ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 24 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com ®...
  • Page 25: Rigid Pipe Venting Systems

    American Metal Products, Security Secure Vent , AmeriVent Direct Vent. AstroCap is the proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 26: Horizontal Termination

    (centre-line of 40-1/2"). Remember to include the mantel base (3" in height) in your calculations and to maintain the 2" clearance from the top with rigid or fl ex pipe systems to the underside of the mantel top. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 27: Venting Arrangements Vertical Termination

    Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adaptor when using rigid vent systems (Part # 510-994). ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 28 • Vent must be supported at offsets • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles. Diagram 1 ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 29: Horizontal Venting With Two (2) 90 Elbows

    Please note min. 1 foot between 90 6' Min. 5' Max. 11' Min. 8' Max. elbows is required. 7' Min. 6' Max. 12' Min. 9' Max. Lengths do not include elbow indicated. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 30: Vertical Venting With Two (2) 90 Elbows

    Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. Lengths do not include elbow indicated. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 31: Vertical Termination With Co-Linear Flex System

    Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Adapter with Kit# Rigid Pipe Adapter 946-563 # 510-994 90 Degree Elbow Inner Pipe Adapter with Kit# 946-563 ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 32: Venting Arrangement - Vertical Terminations

    VENTING ARRANGEMENT - VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL & MANUFACTURED HOMES Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 33: Unit Installation With Horizontal Termination

    “Mill-Pac” sealant (supplied) to every in- down. ner pipe connection. Failure to do so may result in drafting or performance issues not Diagram 3 covered under warranty. Silicone (red RTV) is optional. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 34: Unit Installation With Vertical Termination

    10" over 16/12 to 18/12 2.13 square and attach over 18/12 to 20/12 2.29 with wood screws Diagram 3 (Diagram 7). over 20/12 to 21/12 2.44 Diagram 7 ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 35: Direct Vent System (Flex) Installation Procedures

    1" (25mm) clearance is needed at the termination end. We recommend framing a 10"(254mm) x 10"(254mm) (inside dimensions) hole to give structural rigidity for mounting the termination. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 36: P36D-Ng1 System Data

    INSTALLATION The manifold pressure is controlled by a regulator always best to consult with your local authorities P36D-NG1 SYSTEM DATA built into the gas control, and should be checked and the CAN/CGA B149 installation code. at the pressure test point.
  • Page 37: Conversion From Ng To Lp

    Open the fl ush door and remove the Before re-installation of the burner (once door. the LP conversion is complete), the air defl ector must be installed. See step 18a. Remove the logs and embers (if already installed). ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 38: Installation Of The Dc Sparker

    Do not over tighten the screw. converted to LPG" near or on top of the Recommended to serial # decal. grip the wrench by the short side. 20) Replace yellow "NG" label with red "LPG" label. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 39 38) Check for proper fl ame appearance and compartment. glow on logs. Heat Shield NOTE: The battery in the DC Sparker Battery Box will need to be replaced an- Compartment nually. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 40: Optional Brick Panels

    fl at up against the wall. Be very careful not to scratch them on the fi rebox hardware. Note: If the bottom brick panel must be removed: Remove the Rear Log Stand, then remove the Burner Tray. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 41 Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position. Sprinkle the vermiculite over base brick panel. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 42: Log Set Installation

    Position Log 02-54 across the cutouts in Logs 02-51 and 02-53. The notch in the bottom right end fi tting against the 5th grate tab. Rear Bracket Cutouts 02-54 02-51 5th Grate Tab ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 43 02-51 02-54 Front Brackets Log Indentation 02-55 02-53 Notch 02-50 02-52 02-54 Rear Grate Tab Photo shows rear grate tab. Log 02-51 was removed to show the positioning of Log 02-52. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 44 If there is any fl ame hesitation, check that area for any blockage of the burner ports. 02-75 02-55 02-50 02-54 02-51 ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 45: Standard Flush Door

    Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3. Diagram 1 Diagram 3 To remove the fl ush door, reverse the above steps. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 46: Remote Control (Optional)

    20 GA. 12 Ft. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" 22 GA. 9 Ft. mode. The remote control is now ready for operation. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 47: Wiring Diagrams

    Caution: Ensure that the wires do CAUTION: Label all wires prior not touch any hot surfaces and are to disconnection when servic- away from sharp edges. ing controls. Wiring errors can cause improper and dangerous operation. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 48 INSTALLATION PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 49: Optional Fan Installation

    Refer to wiring diagram. 10) Remove the control box assembly and push the hold-down clip onto the louver. Bend the tab until it is at 90 to the louver. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 50: Operating Instructions

    2) Turn gas control knob so indicator points PLACE. operating sounds and should not be considered to "OFF" position and allow 5 minutes for as defects in your appliance. any gas in the combustion chamber to escape. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 51: Copy Of The Lighting Plate Instructions

    Visually check the fl ame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed service person. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 52: General Vent Maintenance

    4) Reverse the previous steps, replace the replace if necessary. glass clips and fasten with the nuts but do not over tighten, as this can break the glass. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 53: Removing Valve

    18) Fire up the unit again and check for proper wrench. fl ame appearance and glow on logs. 15) Undo the "gas out" fl are fi tting with an 11/16" wrench. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 54: Flush Trim

    ® REGENCY OPTIONS FLUSH TRIM FLUSH LOUVERS 1) Install the top louver by sliding the two Attach the round magnets to the back of the bracket clips into the brackets located top trim piece and to the bottom trim piece, underneath the top of the fi...
  • Page 55: Bay Door

    ® REGENCY OPTIONS INSTALLATION 2) Install bottom louver by sliding the two BAY DOOR BAY TRIM bracket clips into the brackets located underneath the bay door. Secure with 1 The Bay louvers MUST be used Attach supplied magnets each to the back of...
  • Page 56: Full Screen Door Installation

    ® REGENCY OPTIONS FULL SCREEN DOOR INSTALLATION 1) Before beginning the installation, remove the Screen Doors from the Full Screen Door Frame by fully opening the doors and lifting up off of the hinges. See important note in step 7.
  • Page 57 ® REGENCY OPTIONS INSTALLATION 6) Slide the Top Grill into the louver brackets located on the inside top of the fi rebox. Push in place. 3) Install the hinges to the hinge brackets on the left and right side of the bottom of the outer frame, secure using 2 x #8 Philips Head Screws per hinge.
  • Page 58: Tripoli Screen Door

    ® REGENCY OPTIONS TRIPOLI SCREEN DOOR When installing the optional Tripoli Screen Door Series, a non-combustible material 12" (305mm) above the unit and 6" (153mm) on each side must be used (see Diagram 1). The Tripoli Screen Door Series also requires steel stud framing above and on each side of the unit (refer to Diagram 1).
  • Page 59 ® REGENCY OPTIONS INSTALLATION Note: The facing material has to go on after the unit is set. 4) Place bracket under the Flange. Secure with 2 screws as indicated in Diagram 4. 1) Remove Glass Door. Refer to P36 Manual.
  • Page 60 1” Facing Material Diagram 7 9) Optional Install Optional 3-Panel Arch Door. (Refer to Install 3-Panel A Door Instruction Sheet). 10) Change in Logo Replace existing logo with Regency logo. Diagram 6 ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 61: Hampton Cast Faceplate

    4) Repeat step 3 for the right side faceplate. NOTE: Do not push in side faceplates all the way, allow for room to place the top faceplate. ® ® Regency Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 62: Hampton Cast Grills

    4) Install new hinge brackets using the same 2 screws removed in step 3. Grill Stopper New hinge bracket. Left side shown. 11) Adjust ball plunger if necessary. ® ® Regency Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 63: Parts List

    Conversion Kit - NG to LP *Not available as a replacement part. DOORS & LOUVERS PLEASE REFER SEPARATE SECTION HEAT RELEASE DUCT KIT BRICK PANEL SET ON-OFF SWITCH ASSEMBLY FAN SWITCH ASSEMBLY ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 64: Burner Assembly & Log Set

    79) 791-535 Burner Assy - NG/LP 82) 511-030 Burner Grate Assy 83) 780-028 Rear Log Support Bracket 84) * Defl ector 85) 780-930 Log Set *Not available as a replacement part. ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 65: Regency ® Bay Front Assembly

    PARTS LIST REGENCY ® BAY FRONT ASSEMBLY Part # Description Part # Description 780-931 Bay Front Complete 510-988 Bay Louvers - Black 103) 940-092/P Side Glass 510-993 Bay Louvers - Steel/Black 107) 936-243 Glass Gasket 510-990 Bay Louvers - Gold/Black...
  • Page 66: Regency ® Flush Front Assembly

    PARTS LIST ® REGENCY FLUSH FRONT ASSEMBLY Part # Description Part # Description 132) 512-518 Flush Door Assembly 510-932 Flush Glass Trim (Set) - Gold 135) 940-090/P Glass (Flush) 150) * Flush Glass Trim 136) 936-155 Glass Gasket (Tadpole) 904-196...
  • Page 67: Hampton Cast Faceplate & Grill Assembly

    Cast Faceplate - Left 513-981** Cast Grills (Set) 204) * Top Grill 205) * Bottom Grill *Not available as a replacement part. ** Last digit of part number represents colour: 1=Black Metallic, 5=Enamel Brown ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 68 NOTES ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 69 NOTES ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 70 NOTES ® Regency P36D-1 Zero Clearance Direct Vent Gas Fireplace...
  • Page 71: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 72 ® Register your Regency warranty online www.regency-fi re.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notifi cation of new product updates. • Stay informed about the current promotions, events, and special offers on related products.