Regency Excalibur P90E Zero Owners & Installation Manual page 33

Clearance direct vent gas fireplace
Table of Contents

Advertisement

Horizontal Venting with Two (2) 90
Must Use: 5" x 8" Simpson Direct Vent Piping with FPI
Increaser Starter Collar (Part #946-605)
One 90
elbow = Two 45
o
Option
V
H + H1
A)
6" Min.
2' Max.
B)
1' Min.
3' Max.
C)
2' Min.
4' Max.
D)
3' Min.
5' Max.
E)
4' Min.
6' Max.
F)
5' Min.
7' Max.
G)
6' Min.
8' Max.
Horizontal Venting with Three (3) 90
Must Use: 5" x 8" Simpson Direct Vent Piping with FPI Increaser Starter
Collar (Part #946-605)
One 90
elbow = Two 45
o
Option
V
H
A)
6" Min. 1' Max. 1'6" Min.
B)
1' Min.
2' Max. 3' Min.
C)
2' Min.
2' Max. 5' Min.
D)
3' Min.
2' Max. 7' Min.
E)
4' Min.
3 Max. 9' Min.
F)
5' Min.
4' Max. 10' Min.
G)
6' Min.
5' Max. 11' Min.
H)
7' Min.
6' Max. 12' Min.
Elbows
o
elbows.
o
With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90
elbows
o
is required.
Elbows
o
elbows.
o
V + V1
H + H1
W i t h
options, max. total
2' Max.
pipe length is 30
feet with min. of 12
3' Max.
feet total vertical
4' Max.
and max. 9 feet
total horizontal.
5' Max.
6' Max.
Please note min.
1 foot between
7' Max.
90
o
8' Max.
required.
9' Max.
t h e s e
elbows is
Regency Excalibur
installation
P90E-11 Direct Vent Gas Stove
®
|
33

Advertisement

Table of Contents
loading

Table of Contents