gACC-499E/U Communication unit
gACC-499E_U_Manual_EN.doc
DIP switch function: Active at position ON
All switches are in OFF position at delivery,
xcept for DIP switch 7. This will save energy of the batteries.
The internal clock will keep running at normal operating mode.
2.3

Battery connectors

The gACC-499 E/U is equiped with 6 battery connectors.
These are divided into 2 groups.
MAIN POWER
Group1: Connector 1.1; 1,2; 1,3 and 1,4 Main Power
RESERVE POWER
Group 2: Connector 2.1; and 2.2 Back-up and clock power
When applying 2 battery packs, connector 1.1 is used for main
power, and 2.2 is used for back-up.
2.4

Terminals intrinsically safe side

Terminal EX-499-UW
1 GND
2 Encoder signal
3 GND
4 UniWire
9 GND
10 Pulse signal
Connection Encoder or gAVC 1200 or Pulse
PA terminals
2.5

Power supply

2.5.1

Battery supply

The standard battery supply consists of 2 identical battery packs with each
pack containing 2 Lithium batteries connected in series. The operating
voltage is 7,2 Vdc. The battery pack that is connected to connector 1.1 will
be used first for the modem and the battery pack that is connected to
connector 2.2 will be used for the internal clock. After pack 1.1 is
consumed it will switch to pack 2.2. For certain applications additional
battery packs can be applied. These will be connected to connectors 1.2;
1.3 and/or 1.4.
An additional pack can be connected to connector 2.1 for extended back-
up.
Warning: Always use batteries of the same type
Function
Signal line -
Signal line +
Signal line gAVC 1200 XP2 terminal B
Signal line gAVC 1200 XP2 terminal A
Signal line - (only possible with Safety Barrier channel 4)
Signal line + (only possible with Safety Barrier channel 4)
Encoder
1 NAMUR (-)
2 NAMUR (+)
The PA-terminals are to be connected to the PA-connection of the installation.
This can be done by using 4mm
2
1,5mm
.
GA-02.035-EN-30.05.17
gAVC 1200
3 UniWire B (klem XP2)
4 UniWire A (klem XP2)
2
yellow/green wire or by using 2 wires of
Page 6 of 46
DIP switch
Battery connectors
Puls
9 GND
10 Pulse signal

Advertisement