gAvilar gACC-499E/U Manual page 12

Communication unit for encoder/gavc 1200
Table of Contents

Advertisement

gACC-499E/U Communication unit
gACC-499E_U_Manual_EN.doc
dual2
swversion req="2.01"
general
confversion="1"
loglevelstdout=3"
checkpwdlocal="Y"
readcfgallowed=N"
sleepallowed="Y"
battlifeoffset="6"
dualmainbatt="N"
otapurl=
<reset hour="17"
minute="30"/>
daylight="Y"
device
name="gprs003"
type="CLKTENC"
timesync="Y"
fullsynctimediff="Y"
clearonstartup="N"
log_interval="60"
archive_config=
"T,ENC,IMP"
persistentdata="N"
params= "DevIdent
=U1200_"
/device
protocol
type="iec62056-21"
daylight="N"
billingdaylight="Y"
password="Y"
Here begins the second block of the configuration (DIP-switch 5 to OFF)
Minimum software version in the gACC-499E/U for this application
This is the current configuration version. This can be increased by 1, and then with the
next data transmission the available data in the current interval will be sent.
Specifies the level of logging. 0 is the highest level and 3 is the lowest level. A choice can
be made between 0, 1, 2 and 3. During normal operation level "3" is selected. This is only
used for communication analysis .
Enter ="N" or "Y". N is the choice of not applying a password. When Y is entered, a
password is used to gain access to the gACC-499E/U.
Enter ="N" or "Y". Y allows reading of the configuration and when N is entered, it's not
possible to read the configuration without a password
Enter "N" or "Y". For battery powered devices the "sleep" mode can be suppressed for a
fixed time. This affects the battery life span.
This determines the number of months on which a low battery warning will appear before
the end of the calculated life span of the batteries. 0/12 can be entered
In case of application of a battery at Bat2 and Bat3 a "Y" must be entered.
http://www.gasdatawarehouse.de/GprsUpdate/ClkGprs.jad
specified for automatic updates.
With mains powered or permanent powered modems an automatic reset must be
performed daily.. The time is entered at reset hour. This should preferably be done shortly
before the read-out takes place, in order to have the cache complete during read-out. The
daylight parameter ensures that summertime is applied.
The type of device is opened.
The name of the device.
This is the type of modem set for a encoder, temperature and pulse
Time synchronization is disabled or with "Y" enabled.
With fullsynctimediff="Y" unlimited time changes can be made. With "N" this is max. 10
seconds.
During start-up of the modem all stored data will be deleted from the cache memory.
The selected parameters will be archived with an interval of "60" minutes. Hourly values
are indicated with "60".
For the here entered parameters Temperature, Encoder and Pulse a measurement must
be created. In the omission of a measurement the corresponding parameter must also be
omitted. T stands for Temperature, ENC for encoder and IMP for Pulses.
Persistent data "Y" indicates that the data remains intact and archived in such a way that
it will be available on a later date/time. This is for the ECG-499E/U not necessary.
The identity of the device can be determined in the config. In many cases this will be
U1200_ in which after the identity the serial number of the device is transmitted. For
certain AMR systems FLO5UF12345678 will be used in which 12345678 is the serial
number the device.
The device is closed.
The used protocol is opened.
The type is IEC 62056-21 before IEC1107
Summertime is disabled or with "Y" enabled. The device operates throughout the year in
wintertime.
The index end of month will be displayed on the first of the month at 06:00 local time
A P1 password is used by the IEC62056-21 protocol
GA-02.035-EN-30.05.17
Page 12 of 46
Here is the update path (URL)

Advertisement

Table of Contents
loading

Related Products for gAvilar gACC-499E/U

Table of Contents