The Configuration Program - gAvilar gACC-499E/U Manual

Communication unit for encoder/gavc 1200
Table of Contents

Advertisement

gACC-499E/U Communication unit
gACC-499E_U_Manual_EN.doc
2.11

The configuration program

GA-02.035-EN-30.05.17
Page 14 of 46
Modem
Com-port setting
Baud rate should always be
2400. The password applies to
the configuration.
The phone number is applied
to the used SIM-card.
The modem init string is
required when connecting via a
modem. When using a config
cable this field should be left
empty.
The data format has to be set
to 8n1 and the checkbox
Config adapter must be ticked.
With Reset pw the Config
password can be reset. This
requires the existing password.
Mobile network
Enter operator and when
required a PIN.
For GPRS connection enter an
APN. The server socket is
used in case of a GPRS socket
connection.
With "home" the provider of the
placed SIM-card is used as
default.
Server 1
The password is the P1
password for IEC62056-21
communication. The server
type must always be set to
LOCAL.
For GSM communication it's
not allowed to enter a NTP-
server
With "Read" the configuration
is read form the gACC and
with "Write configuration into
the modem" the configuration
is written into the modem.
Password must be entered
when required.