Adjusting The Minimum Gas Level On The Oven Burner - Zanussi ZCG64396XA User Manual

Table of Contents

Advertisement

2. Carefully remove from the burner the
thermocouple A. Next remove the spark plug B.
3. Unscrew the screw and slowly pull out the
burner.
4. Release the burner injector with a 7 mm socket
spanner and replace it with a right one.
24
A
B
1
2
Assemble the burner in a revers sequence.
Replace the gas type sticker near the gas supply
ramp with the one related to the new gas type.
ADJUSTING THE MINIMUM GAS LEVEL ON
THE OVEN BURNER
1. Disconnect the appliance from the electricity.
2. Remove the knob for the oven functions. If
there is no access to the bypass screw
dismount the control panel before adjustment
start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
Changing from natural gas to liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
3. Connect the appliance to the electricity.
Changing from liquid gas to natural gas
1. Unscrew approximately one turn the bypass
screw position A.
2. Put the knob for the oven functions back.
3. Connect the appliance to the electricity.