Siemens Sinumerik 840D sl Programming Manual page 482

Fundamentals
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Tables
17.5 Predefined procedures
Interrupts
Identifier
Parameter
1.
DISABLE
INT:
Number of the in‐
terrupt input
ENABLE
INT:
Number of the in‐
terrupt input
CLRINT
INT:
Number of the in‐
terrupt input
Synchronized actions
Identifier
Parameter
1. – n.
CANCEL
INT:
Number of the synchronized action
Function definition
Identifier
Parameter
1.
FCTDEF
INT:
Function num‐
ber
Communication
Identifier
Parameter
1.
MMC
STRING:
Command
*
Commands are acknowledged on request from the executing component (channel, NC, etc.).
)
482
Explanation
Deactivates the interrupt routine assigned to the specified hardware input. Fast
retraction is not executed. The assignment between the hardware input and the
interrupt routine made with SETINT remains valid and can be reactivated with
ENABLE.
Reactivation of the interrupt routine assignment deactivated with DISABLE.
Delete assignment of interrupt routines and attributes to an interrupt input. The
interrupt routine is deactivated and no reaction occurs when the interrupt is gen‐
erated.
2.
3.
REAL:
REAL:
Lower limit
Upper limit
value
value
2.
CHAR:
Acknowledgement mode*
"N": Without acknowledgement
"S": Synchronous acknowledgement
"A": Asynchronous acknowledgement
Explanation
Aborts the modal synchronized action with the speci‐
fied ID. Several IDs, separated by commas, can be
specified.
4.-7.
REAL:
Coefficients a0 -
a3
)
Programming Manual, 01/2015, 6FC5398-1BP40-5BA2
Explanation
Define polynomial function
This is evaluated in SYFCT or
PUTFTOCF.
Explanation
Command to HMI command Inter‐
preter for the configuration of win‐
dows via NC program