Module Software Revision Levels; Factory Settings; General Factory Settings - Trane RTHC Installation Operation & Maintenance

175-450 ton units (60 hz); 125-450 ton units (50 hz)
Table of Contents

Advertisement

Module Software Revision Levels

Press (Enter) To Display Software
Revision Levels Or (Next) To Continue
If <Enter> is selected the following screen can be
displayed 4 times with 4 different pairs of modules.
[Module x:]
[Module y:]
The modules and prefix software PN will be one of
the following:
Chiller
Starter
Options
Stepper
TCI
LCLD (local CLD)
RCLD
CCCLD (Complex
Character CLD)
Refrigerant Monitor
Table 24

General Factory Settings

Operator Settings
Service Settings (Non-Passwd
Protect)
5 - 34
[Software PN]
[Software PN]
6200-0079-xx
6200-0055-xx
6200-0040-xx
6200-0081-xx
6200-0093-xx
6200-0091-xx
6200-0091-xx
6200-0092-xx
Rev -xx
Front Panel Chilled Wtr Setpt
Front Panel Current Limit Setpt
Chilled Water Reset Type
Ice Building
Panel Ice Termination Setpt
Ice-to-Normal Cooling Timer
Chilled Water Setpt Source
Current Limit Setpt Source
Ice Termination Setpt Source
Setpoint Source Override
Language
Display Units
Decimal Places Displayed
Display Menu Headings
Differential to Start Setpt
Differential to Stop Setpt
Evap Pump Off Delay
Where xx is the software revision level as
communicated over the IPC bus. The entire formal
software part number for the particular module will be
displayed for each of the modules or devices shown
above (with the exception of the refrigerant monitor,
which will only display the Rev level). If a software
part number for a given module has not been read by
the CLD at any time since its last reset (RAM
initialization) it will display the words: "not available"
in place of the software PN.
Notes: These screens will display a line item for
every possible module in an RTHC system. If a
module fails during operation, the software revision
for that module will still appear on the CLD until after
a CLD power down reset.

Factory Settings

The following table contains the values and setpoints
for many menu settings as they are normally set in
the factory prior to shipping the unit. Some settings
are same as the ROM defaults (hardcoded settings
to which the UCP would default in the event of
memory errors). Other settings are made in the
factory and based on a particular chiller option or
application requested via the sales order. In the latter
case, the factory settings would differ. Remember,
before making changes to any settings, record the
original pre-set values so that the original settings
could be restored.
44.0 ° F
100%
DISABLE
(per order or application)
27 ° F
5 min
FRONT PANEL
FRONT PANEL
FRONT PANEL
NONE
ENGLISH
ENGLISH
XXX.X
DISABLE
5.0 ° F
5.0 ° F
1.0 MIN
RTHC-IOM-1C