q Inspect the individual pieces of the shipment
before accepting the unit. Check for obvious
damage to the unit or packing material.
q Inspect the unit for concealed damage as soon as
possible after delivery and before it is stored.
Concealed damage must be reported within 10
days after receipt.
q If concealed damage is discovered, stop
unpacking the shipment. Do not remove damaged
material from the receiving location. Take photos
of the damage, if possible. The owner must
provide reasonable evidence that the damage did
not occur after delivery.
q Notify the Trane sales representative and arrange
for repair. Do not repair the unit, however, until
damage is inspected by the transportation
representative.

Loose Parts Inventory

Check all items against the shipping list. Water
vessel drain plugs, isolation pads, rigging and
electrical diagrams, service literature and the starter/
control panel wire pullbox (required on some
starters) are shipped unassembled in the starter
control panel.
Typical Service Model Number (located on unit nameplate):
Number
Ø
RTHC
1
Digit Ø
1,2,3,4
5
Table 1

Model Number for RTHC Chiller

Selection
Category
Chiller Series
Design
Control
Compressor
Frame
Compressor
Capacity
1 - 2
D
2
F
0
A
0
G
6
7
8
9
10
11
12
Description of Selection
Series R Water-Cooled Chiller
WCBU (Pueblo, CO)
LCBU (Charmes, France)
B Frame
C Frame
D Frame
E Frame
Smaller capacity (minor)
Larger capacity (major)
Special 50 Hz capacity

Unit Description

The RTHC units are single compressor, helical-rotary
type, water-cooled liquid chillers designed for
installation indoors. Each unit is a completely
assembled, hermetic package that is factory-piped,
wired, leak-tested, dehydrated, charged (optional),
and tested for proper control operation before
shipment.
Figure 2 and Figure 3 show a typical RTHC unit and
its components. Water inlet and outlet openings are
covered before shipment. The oil tank is factory
charged with the proper amount of refrigeration oil.
The unit can be factory charged with refrigerant.

Model Number Coding System

The model numbers for the unit, the compressor, and
the starter/control panel are composed of numbers
and letters that represent features of the equipment.
Shown in the three tables following are samples of
typical unit, compressor, and panel model numbers,
followed by the coding system for each.
Each position, or group of positions, in the model
number is used to represent a feature. For example,
in the first table, position 08 of the unit model
number, Unit Voltage, contains the letter "F". An F in
this position means that the unit voltage is 460/60/3.
3
L
4
G
3
13
14
15
16
17
Model No.
RTHC
L
G
0
Q
U
18
19
20
21
22
Digit
1-4
1
5
2
B
6
C
D
E
1
7
2
3
RTHC-IOM-1C
C
0
23
24