Functions of the IM 151-7 CPU
8.1

Data for the PROFIBUS-DP

Device master file
A DDB file contains all the slave-specific properties. The structure of the DDB file
is defined in IEC 61784-1:2002 Ed1 CP 3/1.
You only need the DDB file if:
S You are using the ET 200S with a DP master from the SIMATIC S5 range
(configuration with COM PROFIBUS)
S You are using the ET 200S with a non-SIMATIC DP master (configuration with a
non-Siemens tool).
You can download the DDB file from the Internet. You will find all the DDB files
under "Downloads" on the SIMATIC Customer Support web site:
http://www.ad.siemens.de/csi/gsd
Important features
If you do not have the DDB file to hand, the following table lists the most important
features of the IM 151-7 CPU.
Table 8-1

Attributes from the device database (DDB) file

Feature
Manufacturer ID
Supports FMS
Supports 9.6 kbaud
Supports 19.2 kbaud
Supports 45.45 kbaud
Supports 93.75 kbaud
Supports 187.5 kbaud
Supports 500 kbaud
Supports 1.5 Mbaud
Supports 3 Mbaud
Supports 6 Mbaud
Supports 12 Mbaud
Supports the FREEZE control command
Supports the SYNC control command
Supports automatic transmission rate detection
PROFIBUS address modifiable by software
Length of user-specific parameter assignment data
User-specific parameter assignment data
8-2
DP code word to
IEC 61784-1:2002 Ed1 CP 3/1
Ident_Number
FMS_supp
9.6_supp
19.2_supp
45.45_supp
93.75_supp
187.5_supp
500_supp
1.5M_supp
3M_supp
6M_supp
12M_supp
Freeze_Mode_supp
Sync_Mode_supp
Auto_Baud_supp
Set_Slave_Add_supp
User_Prm_Data_Len
User_Prm_Data
ET 200S IM 151-7 CPU Interface Module
IM 151-7 CPU
80E2
H
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
3 bytes
Yes