Chapter 7
Motion Control
112
General Parameters
Parameter
Description and Values
- Active Level
Set as High (default) or Low.
Drive ready input
Servo Ready Input Enable flag.
Check the option box to enable the input.
- Input
The list of digital input variables. Select an input.
- Active Level
Set as High (default) or Low.
Touch probe input
Configure whether an input for touch probe is used.
Check the option box to enable touch probe input.
- Input
List of digital input variables. Select an input
- Active Level
Set the active level for touch probe input as High (default) or Low.
PTO Channel Naming
Names of embedded PTO channels have the prefix EM (embedded) and each
available PTO channel is enumerated starting from 0. For example, a controller
that supports three axes will have the following PTO channels available:
• EM_0
• EM_1
• EM_2
Motor and Load
Edit the Motor Load properties as defined in the table.
Certain parameters for Motor and Load are Real values. For more
IMPORTANT
information, see
Real Data Resolution on page 118
Rockwell Automation Publication 2080-UM002K-EN-E - March 2019