Manual
Double Sheet Detector R1000 series E20
B0046991 / Rev. 1.6
Mounting
Version E20-4P for up to four sensors
M6
RS232
76
SPS
Power
Sensor 1
Sensor 2
Sensor 3
Sensor 4
PG16
PG9
PG11 EMV
PG11 EMV
PG11 EMV
PG11 EMV
53
30
15
20
50
80
106
132
158
173
Befestigungsbohrungen
für Schrauben M4
Mounting holes
for screws M4
All dimensions are in mm. Tolerance: ±0.2 mm
Fig. 15: Dimensions of the wall mount enclosure - front view
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33