B0046991 / Rev. 1.6
2.5.1.2
Sensor cable CPS for sensors P36GS, P42GS, P75GS and P75VGS
Receptacle contact
1)
3
2
4
5
1
6
1)
View contact side
1
N.C.
2
N.C.
3
N.C.
4
N.C.
5
black (1) [white]
6
black (2) [brown]
blank (shield)
Right angle cable socket (optional)
53
Fig. 10: Sensor cable CPS
to Sensor
Cable socket
P36GS
P42GS
P75GS
P75VGS
Cable types for the P36GS, P42GS, P75GS and P75VGS sensor (order data):
CPS-GOIL
CPS-WOIL
The standard length is 5 meter. Cable length up to 50 meter made to order, longer cables please
enquire.
The cable is drag cable suitable and oil resistant.
Cable type:
Oilflex FD810CY 2 x 1mm
Unitronic FDCP (TP) plus 1 x 2 x 1mm
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
to sensor
Cable socket
78
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
75
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
Ø 30
1
2
2
3
3
4
4
5
5
6
6
(straight receptacle at the sensor)
(right angle receptacle at the sensor)
In particular with larger lengths the sensor cable should not be placed
Note
directly adjacent to cables with large noise potential.
2
Manual
to control unit
Bootlace ferrules
black (1) [white]
black (2) [brown]
black (1) [white]
black (2) [brown]
to control unit
Bootlace ferrules
C
2
(UL / CSA)
Technical data
A
black (1) [white]
B
black (2) [brown]
C
blank (Shield)
25