B0046991 / Rev. 1.6
During the zero adjust the following message is shown:
program par.
zero adj.:active
Fig. 49: Display during zero adjust
When the zero adjust is completed, the following message appears:
program par.
zero adj.:
Fig. 50: Zero adjust successfully completed
The zero adjust is now completed.
Program parameter 7: Teach-in
program par.
teach-in:
Fig. 51: Status of Teach-in
Possible choices:
off:
on:
For performing a teach-in, select "on" and press the ENTER key (if no teach-in was done or if a
teach-in has to be repeated).
Then the operator is requested to attach a sheet with nominal thickness:
program par.
attach sheet !
Fig. 52: Request for attaching a sheet
Attach a sheet with nominal thickness.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
the choices "separate" and "common" are available only for 4P versions
Note
with more than one sensor connected.
6
Fault messages are described in the chapter
Note
"9 Fault messages".
6
off
7
on
A teach-in has not been executed
A teach-in will now be performed
7
A sheet must be attached to the sensor without air gap. The position
Attention
of the sheet during teach-in must be the same as for normal
operation. Otherwise the measurement result could be faulty.