One Unit Shows 0W Of Production But Adjacent Units Are Productive; Why Is One Unit Showing 0W Production When Adjacent Units Are Productive - enphase M250 Troubleshooting Manual

Hide thumbs Also See for M250:
Table of Contents

Advertisement

The seven-day time-lapse animation of a non-productive, or under producing PV/microinverter
pair repeats can show production patterns that indicate shading. The following Enlighten
snapshot shows an example of a system with shading impacts. To view a time-lapse animation of
a system:
In the View tab, click the Energy/Power drop-down menu. Under Power, select Past 7 Days.
Click the playback icon. Use the controls at the base of the screen to pause, replay and
change the speed of the animation playback..
If the periods of low production are consistent and happen at the same time of day, then shading
is likely the cause.
2. Refer to "Messages and Alerts" on page 33 for other possible causes of low production.

One unit shows 0W of production but adjacent units are productive

The microinverter is communicating, but not producing. Communication with no production may indicate a
DC-side failure.
Use Enlighten to view AC measurements for analysis. To view the AC measurements:
1. In the View tab, click the module. A status message displays.
2. Click the graph icon.