UPSI-1208(D) | UPSI-2406(D)
GetChargeStatusRegister() 0x1B
This read-word function returns the status flags.
Cmd
Name
0x1B
GetStatusRegister()
Transfer packet:
0x01 0x03 0x03 0x1B 0x04
Bit Field:
SD SU CV UV CL RV RV RV RV CC RV PF RV RV RV RV
LSB
BIT
0
SD Shows that the device is in step-down (charging) mode.
1
SU Shows that the device is in step-up (backup) mode.
2
CV Shows that the charger is in constant voltage mode.
3
UV Shows that the charger is in undervoltage lockout.
4
CL Shows that the device is in input current limit.
5
RV Reserved Bit
6
RV Reserved Bit
7
RV Reserved Bit
8
RV Reserved Bit
9
CC Shows that the charger is in constant current mode.
10
RV Reserved Bit
11
PF Shows that the input power is failed.
12
RV Reserved Bit
13
RV Reserved Bit
14
RV Reserved Bit
15
RV Reserved Bit
GetInputVoltage() 0x25
This read-word function returns the measured input voltage of the UPS.
Cmd
Name
0x25
GetInputVoltage()
Transfer packet:
0x01 0x03 0x03 0x25 0x04
Access
Type
R
Bit Field
Description
Access
Type
R
Int16
Min.
Max
Unit
-
-
True / False
Min.
Max
0
32768
MSB
Unit
mV