Bicker UPSI-1208D User Manual page 31

Table of Contents

Advertisement

Available languages

Available languages

UPSI-1208(D) | UPSI-2406(D)
GetBatteryDeviceName() 0x21
This read-block function returns the assigned pack name.
Cmd
0x21
GetBatteryDeviceName()
Transfer packet:
0x01 0x03 0x04 0x21 0x04
GetBatteryCellVoltage4() 0x3C
This read-word function returns the Cell 4 voltage.
Cmd
0x3C
GetBatteryCellVoltage4()
Transfer packet:
0x01 0x03 0x04 0x3C 0x04
GetBatteryCellVoltage3() 0x3D
This read-word function returns the Cell 3 voltage.
Cmd
0x3D
GetBatteryCellVoltage3()
Transfer packet:
0x01 0x03 0x04 0x3D 0x04
GetBatteryCellVoltage2() 0x3E
This read-word function returns the Cell 2 voltage.
Cmd
0x3E
GetBatteryCellVoltage2()
Transfer packet:
0x01 0x03 0x04 0x3E 0x04
GetBatteryCellVoltage1() 0x3F
This read-word function returns the Cell 1 voltage.
Cmd
0x3F
GetBatteryCellVoltage1()
Transfer packet:
0x01 0x03 0x04 0x3F 0x04
Name
Name
Name
Name
Name
Access
Type
R
Char[20]
Access
Type
R
Uint16
Access
Type
R
Uint16
Access
Type
R
Uint16
Access
Type
R
Uint16
Min.
Max
Unit
-
-
ASCII
Min.
Max
Unit
0
65535
mV
Min.
Max
Unit
0
65535
mV
Min.
Max
Unit
0
65535
mV
Min.
Max
Unit
0
65535
mV
31