  • Page 3: Table Of Contents

    SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ......................Mounting the Range Hood ........Ductless Recirculating ..........FEATURES & CONTROLS Capacitive Touch Controls ........MAINTENANCE Cleaning, Filter Care, Lights, Parts List .....
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
  • Page 6 www.zephyronline.com MODELS: ZOM-E30AS, ZOM-E36AS ZOM-E30ABS, ZOM-E36ABS PARTS SUPPLIED 1 - Hood with internal blower 2 - Aluminum mesh filters 1 - Duct cover assembly (top and bottom) 1 - Duct cover wall bracket 2 - Halogen light bulbs 1 - Hardware package HARDWARE PACKAGE CONTENTS (2) 6# x 1-1/2”...
  • Page 7 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
  • Page 8 www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 6” to 7”. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.
  • Page 9: Ducting Options

    WARNING FIRE HAZARD All exhaust must be ducted to the outside, unless using the recirculating option. Some Ducting Options Roof Pitch w/ Flashing & Cap side wall cap w/ gravity damper Soffit or crawl space side wall cap w/ gravity damper ductless recirculating...
  • Page 10 www.zephyronline.com 8 3/4” 6 7/8” Standard min. ducted - 27 1/2” min. recirc - 32” max. 42 1/2” Z1C-01OMS Z1C-01OMBS min. ducted - 46 1/2” min. recirc. - 50 1/2” max. 80” 29 7/8”, 35 7/8” 19 3/4” FRONT SIDE 7/8”...
  • Page 11 CAUTION: At least two installers are required due to the weight and size of the hood. Duct Cover Bracket 3-1/2" 2" 12 1/4" fasten screws all the way. Note: wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also be used but check local codes for compliance.
  • Page 12 www.zephyronline.com When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct is not possible should you recourse to converting the hood into a recirculating hood. Aluminum Mesh Filter set.
  • Page 13 Delay Off Timer Indicator Speed Indicators Lights On/Off Power / Delay Off Lights Indicator clean filters Fan Speed Increase Clean Filter Indicator Fan Speed Decrease Power / Delay Off Button Button will turn power on and off for entire hood (fan and lights. - Hood will remember the last speed and light level it was last turned off at.
  • Page 14 www.zephyronline.com SURFACE MAINTENANCE: Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel stainless steel grain.
  • Page 15: Troubleshooting

    TROUBLESHOOTING PROCEDURES FOR OMBRA WALL Issue Cause What to do After installation, 1. The power source is not turned ON. the unit doesn’t power is ON. is not connecting properly. connected properly. 3. The wires on the control board are loose.
  • Page 16: Wiring Diagram

    www.zephyronline.com Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the codes for CFM restrictions. By default the maximum blower CFM is set to 600. CAUTION: Hood must be disconnected from main power prior to performing the conversion instructions listed below.
  • Page 17 ZOM-E30AS, ZOM-E30ABS ZOM-E36AS, ZOM-E36ABS ACT 390 CFM - Fan Max. @ 2.5A ACT 290 CFM - Fan Max. @ 2.0A...