JX3-THI2-TC
15.3

DC Power Supply Inputs and Outputs

Operating Parameters - EMC (Emitted Interference)
Parameter
Signal and control
interface
DC power supply inputs
and outputs
Operating Parameters - EMC (Immunity to Interference)
Parameter
RF, asymmetric
Bursts
Voltage surges,
asymmetric (line to
earth),
symmetrical (line to
earth)
Jetter AG
Value(s)
Frequency bands:
0.15 to 0.5 MHz,
limit 40 to 30 dB
0.5 to 30 MHz,
limit 30 dB
(class B)
Value(s)
Frequency band 0.15 – 80 MHz
Test voltage 3 V
AM 80 % at 1 kHz
Source impedance 150 Ohm
Criterion A
Test voltage 2 kV
tr/tn 5/50 ns
Repetion frequency 5 kHz
Criterion A
tr/tn 1.2/50 µs
Common-mode interference
voltage 1 kV
Series-mode interference
voltage 0.5 kV
Appendix
Standard
DIN EN 61000-6-3
Standard
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-6
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-4
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-5