ELIMINATING FAULTS

MALFUNCTION
Machine not running.
Green operating light lights up
Machine not running.
Green operating light not does
not light up
Machine not running.
The red control light is solid or
flashing
The machine does not establish
the required working pressure
or the working pressure is not
constant
Machine builds up pressure in
the mortar hose.
However, coating material does
not arrive at the spray gun.
POSSIBLE CAUSE
Pressure regulator is set to "0"
The pressure sensor control cable is not
connected or is damaged
Rotor stuck in stator.
The pump has not been stored with
conservation agent.
Power supply missing.
Controller faulty
Machine was overloaded/overheated.
Diameter of the extension cable too
small
The stator and rotor are faulty or worn. Replace the stator and rotor (Art. No. 2395996, see
Coating material "plug" in the high
pressure hose.
ELIMINATION
Increase the pressure
Check the control cable
Set the selector switch alternatively briefly to "F"
(forwards) – "R" (reverse).
If this does not resolve the problem, replace the
stator and rotor (see Section 9.4)
- Plug in the power plug.
- Check the power cable for damage and replace,
if necessary.
- Check the power supply.
- Please contact Wagner Service
- Switch the machine off and disconnect mains
plug
Switch the machine on again after about 5
minutes.
If the problem does not resolve, contact Wag-
ner Service
The number of flashes represents
an error code. Tell Service what this
error code is so that the error can be
remedied faster.
- Use an extension cable with a diameter of 3 x
2.5 mm2.
Section 9.4)
Depressurize the high pressure hose – set the se-
lector switch to "R" (reverse).
Pump the coating material back into the contain-
er.
The high pressure hose must be
pressureless.
Watch the manometer ––> 0 bar.
Wear safety goggles.
Decouple high pressure hose and rinse with water
hose. Couple the high pressure hose back on.