Fr-V500 Series - Mitsubishi Electric FR-A5NPA Instruction Manual

Profibus/dp communication option
Table of Contents

Advertisement

3.3.2 FR-V500 series

Pr. 338 "operation control
Control
command source"
location
Pr. 339 "speed command
selection
Forward rotation command (STF)
Reverse rotation command (STR)
Reset (RES)
External thermal relay (OH)
Computer link operation speed
2
Speed setting auxiliary
1
Magnetic flux command/
regeneration torque restriction
3
Low-speed operation command,
0
Remote setting (setting clear) (RL)
Middle-speed operation command,
1
Remote setting (deceleration) (RM)
High-speed operation command,
2
Remote setting (acceleration) (RH)
3 Second function selection (RT)
5 Jog operation selection (JOG)
8 15-speed selection (REX)
9 Third function (X9)
FR-HC connection, FR-CV
10
connection (inverter operation
enable) (X10)
11 FR-HC connection (instantaneous
power failure detection) (X11)
12 PU operation external interlock (X12) External External External External
14 PID control enable terminal (X14)
Brake sequence opening
15
completion signal (BRI)
PU-external operation switchover
16
(X16)
S-pattern acceleration/deceleration
20
C switchover (X20)
22 Orientation command(X22)
23 Pre-excitation/servo ON (LX)
24 Output stop (MRS)
25 Start self-holding selection (STOP)
26 Control mode changing (MC)
27 Torque restriction selection (TL)
42 Torque bias selection 1 (X42)
43 Torque bias selection 2 (X43)
P control selection (P/PI control
44
switchover) (X44)
External
: Control by signal from external terminal is only valid.
NET
: Control from Profibus master module is only valid.
Combined
: Control from both external terminal and Profibus master module is
valid.
: Control from both external terminal and Profibus master module is
invalid.
Compensation : Control by signal from external terminal is only valid if Pr. 28 "multi-
speed input compensation" setting is 1.
source"
INVERTER SETTING
0: NET
0: NET
1: External 1: External
0: NET
1: External
0: NET
NET
NET
External External
NET
NET
External External
Combined Combined Combined Combined
External External External External
NET
NET
External
Compen
Compen
External
sation
sation
External External External External
External
NET
External
NET
NET
External
NET
NET
External
NET
NET
NET
External External
External External
NET
External
NET
NET
NET
External External
External External External External
External External External External
NET
External
NET
NET
NET
External External
External External External External
NET
NET
External External
NET
NET
External External
NET
NET
External External
External External
Combined Combined
External External
NET
NET
External External
NET
NET
External External
NET
NET
External External
NET
NET
External External
NET
NET
External External
17
REMARKS
1: External
External
External
External
External
Pr. 59 ≠ 0:
External
Remote
setting
External
External
External
*2

Advertisement

Table of Contents
loading

Table of Contents