Profibus Pnu; Real-Time Monitor - Mitsubishi Electric FR-A5NPA Instruction Manual

Profibus/dp communication option
Table of Contents

Advertisement

8.2 Profibus PNU

8.2.1 Real-time monitor

The following items can be monitored from the master.
PNU
P1.1
Output frequency
P1.2
Output current
P1.3
Output voltage
P1.5
Speed setting
P1.6
Running speed
P1.7
Motor torque
P1.8
Converter output voltage
P1.9
Regenerative brake duty
P1.10
Electronic thermal overload protection load factor
P1.11
Output current peak value
P1.12
Converter output voltage peak value
P1.15
Input terminal status (refer to page 58 (1))
P1.16
Output terminal status (refer to page 58 (2))
P1.17
Load meter
P1.18
Motor excitation current
P1.19
Position pulse
P1.20
Cumulative energization time
P1.23
Actual operation time
P1.24
Motor load factor
P1.32
Trace status
P1.33
Torque current command
P1.34
Motor output
P1.35
Feedback pulse
P1.38
Trace status
PARAMETER DEFINITIONS - V500 SERIES
Item
57
Data
Unit
Type
0.01Hz
AUs16
0.01A
AUs16
0.1V
AUs16
1r/min
AUs16
1r/min
AUs16
0.1%
AUs16
0.1V
AUs16
0.1%
AUs16
0.1%
AUs16
0.01A
AUs16
0.1V
AUs16
-
AUs16
-
AUs16
0.1%
AUs16
0.01A
AUs16
-
AUs16
1h
AUs16
1h
AUs16
0.1%
AUs16
0.1%
AUs16
0.1%
AUs16
0.01kW
AUs16
-
AUs16
-
AUs16

Advertisement

Table of Contents
loading

Table of Contents